HILNA HF w/ AGC User Manual
Rev ‐
10
4.1.2
MGC SETTINGS
In MGC mode, the user has the ability to control the level over a range of 60 dB. The default setting is
0000. Each count represents approximately 0.5 dB worth of attenuation. For example, the command
string “ATTA0044” sets Attenuator 1 to approximately 22 dB of attenuation. Table 11 illustrates the
MGC attenuator settings.
Table 12: MGC Attenuator settings
Op Code
Parameter
Range
Description
atta
dddd
0000 ‐ 0063
Select Manual Gain for Attenuator 1
attb
dddd
0000 ‐ 0063
Select Manual Gain for Attenuator 2
4.1.3
HILNA HF AGC CONFIGURATION SETTINGS
The following are the factory default settings and are present upon initialization of the receiver:
Automatic Gain Control Mode ON (AGC on)
+2 dBm nominal output
Attack / Decay times of 100 mS
Table 13: Configuration Commands
Op Code
Parameter
Description
con
def
Reset configuration to stored default
con
sto
Store current configuration as startup settings
stat
?
Returns current settings
When changes are made to the system settings, they are only valid as long as the unit remains powered
on. To keep desired settings, the CONSTO command will store the current settings to memory, and the
stored settings will be retained and used on the next startup. Note that any settings saved using
CONSTO will overwrite the factory settings.