background image

HILNA GPS User Manual 

 

 

 

Document 6002-1300-1201 Rev 

 08222014 

2.1

 

HILNA GPS ELECTRICAL DATA 

 

Table 2: HILNA GPS Absolute Maximum Rating 

 

Operating Voltage 

+20 VDC 

RF P

in

 

+15 dBm 

Operating Temperature 

-30 to + 70 

0

Storage Temperature 

-40 to + 85 

0

 

Table 3: HILNA GPS DC Specifications 

 

 

 

Min 

Typ 

Max 

Operating Voltage 

+5 

+12 

+20 

Current Consumption 

mA 

130 

140 

150 

 

Table 4: HILNA GPS RF Specifications 

 

PARAMETER 

UNIT 

HILNA GPS 

Min 

Typ 

Max 

Frequency Range 

MHz 

1200 

 

1600 

Gain 

dB 

30 

33 

35 

Noise Figure 

dB 

0.7 

.8 

1.6 

OIP3 

dBm 

28 

30 

32 

P1dB 

dBm 

16 

18 

19 

VSWR In 

 

 

1.5:1 

 

VSWR Out 

 

 

2.0:1 

 

Reverse Isolation 

dB 

45 

53 

56 

 

Summary of Contents for HILNA GPS

Page 1: ...PT LOW NOISE AMPLIFIER HILNATM MODEL NUMBER HILNA GPS 6002 1300 1201 Trusted RF Solutions NUWAVES ENGINEERING 132 EDISON DRIVE MIDDLETOWN OHIO 45044 PH 513 360 0800 FAX 513 539 8782 www nuwaves com pr...

Page 2: ...d in a nickel plated rugged aluminum enclosure with mounting holes incorporated into the chassis Completely Characterized The HILNA family of low noise amplifiers has been completely characterized ove...

Page 3: ...o achieve high gain while maintaining low noise and a high third order intercept point specifically for L1 1575 43 MHz and L2 1227 6 MHz GPS signals This high performance module delivers 32 dB of gain...

Page 4: ...0 to 70 0C Storage Temperature 40 to 85 0C Table 3 HILNA GPS DC Specifications Min Typ Max Operating Voltage V 5 12 20 Current Consumption mA 130 140 150 Table 4 HILNA GPS RF Specifications PARAMETER...

Page 5: ...HILNA GPS User Manual Document 6002 1300 1201 Rev 08222014 4 Figure 2 HILNA GPS Frequency Response...

Page 6: ...CHANICAL SPECIFICATIONS Figure 3 HILNA GPS Mechanical Outline Table 3 HILNA GPS Mechanical Specifications RF Bulkhead Connector SMA female RF Input and Output Mating Connector SMA male DC Power Connec...

Page 7: ...rating voltage The power connector for the units is an industry standard 2 mm circular connector The only restrictions on the power source for the unit are Capable of sourcing 80 mA of current Capable...

Page 8: ...in a well ventilated area or mounted to a heat sink if the input voltage exceeds 12 VDC The unit will run warmer as the input voltage increases 4 GETTING HELP APPLICATIONS ENGINEERING NuWaves Enginee...