background image

20

XVII. NuVo NV-P2100 200 Watt Auxiliary Amplifier

The P2100 is specifically designed for use with the NuVo 
Systems' lineouts. It can be used with either the fixed or variable 
lineouts on the Essentia with either a 1/8” (3.5mm) to 1/8” 
stereo patch cable or a 1/8” stereo to RCA patch cable, Fig 21. 

There are two methods for triggering the NuVo P2100 from the 
Essentia outputs.  One is to set the POWER MODE switch on the 
P2100 to Audio (the extreme left position) and allow an 
incoming audio signal from the Essentia System to turn on the 
P2100. The second method is to place the POWER MODE switch in 
the AC/DC  (extreme right) position. This will turn on the P2100 
when the Essentia is on. An additional feature of Essentia is zone 
specific triggers that will trigger the P2100 only when that zone 
is turned on. 

Utilizing the voltage trigger requires a mono 1/8” (3.5mm) patch 
cable from either the System ON output on the Essentia to the 
P2100 Voltage trigger input, or from the specific Zone Trigger on 
the Essentia to the Voltage Trigger on the P2100, Fig. 22.

R

L

SENSITIVITY

OdBV = 1.0RMS

-12

+6

0

LEFT

+6 

-12

RIGHT

0

AUDIO

INPUT

2

INPUT

OUTPUT

CONTROL

VOLTAGE
TRIGGER

3-30 VOLTS

AC OR DC

ON/OFF SWITCH

AUDIO    AC/DC

POWER

MODE

CONTROL

ZONE 6

ZONE TRIGGER OUTPUTS

EMITTER OUTPUTS

ZONE 5

SUM1

1

2

2

3

1

3

5

2

4

6

SUM2

5

4

5

6

NV-P2100 Amplifier

Essentia
Amplifier

Fig. 21

Fig. 22

R

L

SENSITIVITY

OdBV = 1.0RMS

-12

+6

0

LEFT

+6 

-12

RIGHT

0

AUDIO

INPUT

2

INPUT

OUTPUT

CONTROL

VOLTAGE
TRIGGER

3-30 VOLTS

AC OR DC

ON/OFF SWITCH

AUDIO    AC/DC

POWER

MODE

CONTROL

SOURCE LINK

SOURCE INPUTS 

ZONE 1

ZONE 3

ZONE 2

CONNECT TO

NV-E6DX

USE NV-SLC1

CABLE

1

2

3

4

5

6

1

2

3

4

5

6

ZONE 1

ZONE 3

ZONE 2

OUTPUT POWER

OUTPUT POWER

OUTPUT POWER

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

VARIABLE

OUTPUT

VARIABLE

OUTPUT

VARIABLE

OUTPUT

FIXED

OUTPUT

FIXED

OUTPUT

FIXED

OUTPUT

TIP=L

RING=R

TIP=L

RING=R

TIP=L

RING=R

NV-P2100 Amplifier

Essentia Amplifier

RS232 Interface

The RS232 port allows external two-way communication with the 
Essentia System. Home automation systems such as Crestron and 
AMX can be set up to operate Essentia. The RS232 addendum 
contains the necessary command sets for communication with 
the Essentia System. 

Summary of Contents for NV-LRC1

Page 1: ...EssentiaTM NV E6D UK Installation Manual...

Page 2: ......

Page 3: ...losure that will impede the flow of cooling air 8 Do not install this product near any heat sources such as radiators heat registers stove or other apparatus including heat producing amplifiers that p...

Page 4: ...s d eau comme par exemple baignoires viers piscine sous sol humides Etc 6 Utiliser exclusivement un chiffon sec pour nettoyer ce produit 7 Ne bloqu r aucune ouverture de ventilation Ne pas placer le...

Page 5: ...mplifier Page 10 VII Connecting the IR Emitters Page 10 VIII Expanding Essentia to 12 Zones Page 11 IX Installing the Essentia Keypads Page 11 X Keypad Zone Settings Page 12 Zone EQ Control and Source...

Page 6: ...e Enjoying quality audio throughout the home is simple and affordable with Essentia This installation manual is designed to provide a sequential step by step guide to making full use of the many featu...

Page 7: ...USE NV SLC1 CABLE 1 2 3 4 5 6 1 2 3 4 5 6 OUTPUT POWER OUTPUT POWER OUTPUT POWER OUTPUT POWER OUTPUT POWER OUTPUT POWER 20W 6OHM X2 20W 6OHM X2 20W 6OHM X2 20W 6OHM X2 20W 6OHM X2 20W 6OHM X2 VARIABL...

Page 8: ...zone is currently turned on Keypad Features 1 Volume Level The level of the zone volume is indicated by these LEDs light emitting diodes 2 Power The power button turns that keypad s zone on and off in...

Page 9: ...the system when the phone or doorbell rings 10 Network Input This RJ45 connection is the input for all zone information coming from the Essentia keypads The connection is made using the Network Cable...

Page 10: ...rce specific volume control such as a TV or stereo receiver This is not used for NuVo zone volume 6 Numeric Buttons These buttons provide source specific direct numeric access 7 Power Button This powe...

Page 11: ...em out individually Arrange the wires into the correct color scheme as shown in Fig 1 3 Flatten the wires in their correct order and trim them evenly across the top Most crimp tools have a wire trimme...

Page 12: ...housing the home audio video equipment The amplifier should be plugged in and the power button on the front panel should be turned on before proceeding with the rest of the installation This activates...

Page 13: ...UT POWER 20W 6OHM X2 20W 6OHM X2 20W 6OHM X2 VARIABLE OUTPUT VARIABLE OUTPUT VARIABLE OUTPUT FIXED OUTPUT FIXED OUTPUT FIXED OUTPUT TIP L RING R TIP L RING R TIP L RING R Source 1 Tuner 1 Audio Out VI...

Page 14: ...nstalling the Essentia Keypads You are now ready to install the keypads and complete the Essentia installation This is easily done using a rotary switch located on the back of the keypad to set a spec...

Page 15: ...e Down disables the group function and causes the keypad to operate independently of all other groups fig 11 FLAT 4 dB 4 dB 6 dB 8 dB 6 dB 8 dB Fig 10 Fig 11 X Keypad Zone Settings Each Essentia keypa...

Page 16: ...c e c h a n g i n g a l o c a l z o n e s v o l u m e c o n t r o l o r b y t u r n i n g a l o c a l z o n e s k e y p a d o f f a n d b a c k o n T h e M a s t e r M o d e i s t u r n e d o f f b y...

Page 17: ...N OFF SWITCH AUDIO AC DC POWER MODE OUTPUT POWER 8 OHM 70W X 2 4 OHM 100W X 2 CONTROL USE ONLY WITH 250V FUSE The Zone keypad controls the audio volume Diagram shown using the NuVo P2100 amplifier Sou...

Page 18: ...g the NuVo P2100 amplifier Source 1 Tuner 1 Audio Out Zone Room 1 ZONE 6 SYSTEM ZONE TRIGGER OUTPUTS SOURCE LINK SOURCE INPUTS ZONE 1 NETWORK EMITTER OUTPUTS DIGITAL LINK ZONE 3 ZONE 4 ZONE 5 ZONE 2 P...

Page 19: ...VARIABLE OUTPUT FIXED OUTPUT SUM1 3033118 C US CONFORMS TO UL STD 6500 CERTIFIED TO CAN CSA STD E60065 NuVo Technologies Cincinnati Ohio USA FUSE T5 A 120V 60Hz 500W MODEL NV 6DM SIX SOURCE SIX ZONE...

Page 20: ...r of the LSA40 is automatically engaged LSA40P Back LSA40P Front Zone Room 1 Any NuVo System zone output can be wired to the LSA40 Local Source Amplifier NuVo System zone speakers 50 Watt AC power ada...

Page 21: ...R DESIGNED IN USA 28VDC 5A ZONE 1 MADE IN CHINA RTE TE K I N 3033118 RT E E T K N I CM ZONE 3 ZONE 2 ZONE 4 POWER LSA40PD Front LSA40PD Back 200 Watt AC power adapter included with the LSA40PD AC Powe...

Page 22: ...Four conductor speaker wire from the LSI12 to the zone speakers Speaker input from Essentia or Simplese LSI12 front LSI12 back ZONE 6 SYSTEM ZONE TRIGGER OUTPUTS SOURCE LINK SOURCE INPUTS ZONE 1 NETW...

Page 23: ...on the Essentia to the Voltage Trigger on the P2100 Fig 22 R L SENSITIVITY OdBV 1 0RMS 12 6 0 LEFT 6 12 RIGHT 0 AUDIO INPUT 2 INPUT OUTPUT CONTROL VOLTAGE TRIGGER 3 30 VOLTS AC OR DC ON OFF SWITCH AUD...

Page 24: ...e and prevent any functionality When locked the keypad will simply flash when a function is attempted Pressing and holding the source button again will unlock the keypad All the keypads change when a...

Page 25: ...Listing CAN CSA E60065 00 Source Inputs 1 6 CE Listing SEMKO EN60065 EN55013 input Impedance 10K EN55020 EN6100 3 2 EN6100 3 3 A1 Input Sensitivity for rated power 300mV RMS Input Overload 3V RMS Phys...

Page 26: ...etailed in the owner s manual If no keypad is connected with a given zone address then ZoneSet will default to A OR0 No override B BASS 0 Bass FLAT C TREB 0 Treble FLAT D GRP0 SOURCE GROUPING OFF E VR...

Page 27: ...is ON 1if SOURCE GROUP is OFF yy level below max in dB 00 to 78 dB include lead 0 for all single digit values yy MT if in MUTE state yy XM if external MUTE is being held active zzz MST if this zone is...

Page 28: ...system will restore keypad permanent settings see the User Manual for details on how to perform these settings b an operator manually sets one of these parameters from a keypad This takes the unit out...

Page 29: ...N CR COMMAND ALLMOFF CR ALL MUTE OFF RESPONSE ALLMOFF CR COMMAND ZxxSRCp CR Switch zone xx to SOURCE p 1 to 6 RESPONSE Same response as for ZxxCONSR CR COMMAND ZxxVOLyy CR Set volume of zone xx to lev...

Page 30: ...response as for ZxxSETSR CR NOTE sending this command to the E6D will override the non volatile GROUP setting set from keypad for this zone until power is cycled COMMAND ZxxGRPOFF CR zone xx SOURCE G...

Page 31: ...x is the major version number and yy is the minor version number RESPONSE EXTMON CR Issued whenever the External MUTE first activates closure to ground and 0 whenever the External MUTE de activates o...

Page 32: ...0730...

Reviews: