Screen 5.2 

Screen 6.0 

Screen 7.0 

and pressing the Master button. When this box is 
checked, the Display will request a user-defined four-
digit security code before the task is completed. 

Security Code Lock to enable advanced MENU options: 

When the MENU button is pushed and held, the dis-
play will automatically go into a menu list. These 
options allow the same zone setup parameters as the 
zone edit window, but can be set to require a four-digit 
security code to access. The balance, treble, and bass 
adjustments are not part of the advanced menu setup 
and can be access at any time. 

Slave To:  

This drop-down menu is used to assign addi-

tional "slave" Display Pads to a zone. Up to three addi-
tional Display Pads can be used in any zone and can 
share the same zone parameters as the main Display 
Pad. This is a useful feature for large rooms where 
more than one Display Pad is desired. If slave Display 
Pads are used, we suggest that you disable the IR pass-
through on those to prevent cross-communication. 

5.2 Zones 

(updated) 

When the desired properties for each zone are set, 
click on OK. This will return you to the Zones tab. 
There you will see an updated list of the zones by the 
number they are assigned, as well as the specific 
parameters defined in the Zone Edit window. 

Double-clicking on the zones will reopen the edit win-
dow, where any of the definition properties can be 
modified. 

6. 0 

Security Code 

Some functions on a Display Pad, such as the advanced 
menu options and MASTER mode, are protected by a 
security code. The security code is a four-digit number. 

7. 0 

Update System 

The finished configuration is now ready to be down-
loaded to the Concerto amplifier. While downloading, a 
progress box will show download progress. Once com-
plete, the configuration is permanently stored in flash 
memory. Configurations can always be retrieved and 
edited at a future date. 

21

Summary of Contents for Concerto NV-I8DMS

Page 1: ...Concerto 6 Sound Sources 8 Listening Zones and Generation D Digital Amplification NV I8DMS Installation Manual...

Page 2: ...ety and operating instructions before using this product 2 All safety and operating instructions should be kept for future reference 3 Read and understand all warnings listed on the operating instruct...

Page 3: ...oi doivent tre conserv es afin de pouvoir s y reporter si n cessaire 3 Lire et comprendre tous les avertissements num r s dans les pr cautions d emploi 4 Suivre toutes les pr cautions d emploi pour ut...

Page 4: ...room of the house Easy access HotKey functions allow each Display Pad to be set in a Do Not Disturb mode Source Monitoring from any zone and setting any of the Display Pads to perform as a master cont...

Page 5: ...5...

Page 6: ...EZ Port It is important for future reference to label each Cat 5 cable for its appropriate listening zone The order in which they are plugged into the EZ Port is irrelevant to the system s operation S...

Page 7: ...protective circuitry With all the zones turned off the resulting standby power consumption is extremely low 2 STAND BY LED This blue LED light emitting diode will indicate that the amplifier is plugge...

Page 8: ...for turning on external equipment 10 EXT MUTE This input is designed to temporarily mute any audio playing through the system when the doorbell or phone rings This works in conjunction with the NuVo N...

Page 9: ...functions It allows the user to access specific settings in each zone such as bass and treble balance and panel brightness and it serves as a hotkey that provides a second level of functionality for...

Page 10: ...ion of the insulation exposing the 4 twisted pairs 2 Untwist the wires and fan them out individually Arrange the wires into the correct color scheme as shown in Fig 1 3 Flatten the wires in their corr...

Page 11: ...the appropriate speaker output on the back of the amplifier The prop er termination is Left channel and Right channel and LEFT LEFT RIGHT RIGHT III Installing the Concerto Amplifier System setup works...

Page 12: ...5 with the appropri ate zone number for future reference Once you have plugged the Cat 5 wires into the EZ Port screw the EZ port into its construction bracket using the supplied mounting screws Fig...

Page 13: ...power status of your audio sources Some equipment uses toggling commands for powering on and off that is the commands for on and off are not separate discrete commands This situation is typical ly co...

Page 14: ...w file Configurations are saved with a cfg extension Screen 1 1 1 2 Retrieve Configuration from Concerto To retrieve a configuration from an existing Concerto installation launch the Configurator soft...

Page 15: ...odate for variations in IR modulation frequencies the IR Library has an addi tional drop down menu titled Carrier for each source This allows you to manually choose 30 36 38 40 or 56 as IR modulation...

Page 16: ...successful and it will then return to yellow Repeat this procedure three more times until the desired code is added to the IR Library Edit window You will now see the number of code repeats and the d...

Page 17: ...codes A name not found in the list can be typed in but it is recommended that you use the names provided in the list This conserves memory in the Concerto Clicking on the OK button proceeds directly t...

Page 18: ...has a dual function Pressing the HotKey at the bottom right of the Display Pad accesses the second level of function This key is also labeled Menu A single press of the HotKey and then any number key...

Page 19: ...change the delay time before the com mand is issued The default delay is 25 seconds This can be increased by 25 second increments up to 30 5 seconds Often a command requires mechanical move ment in t...

Page 20: ...level The Initial Volume adjustment allows the zone turn on level to be adjusted to accommodate the zone s needs Loudness Compensation ON The Concerto System has an automatic boost for the bass and tr...

Page 21: ...ooms where more than one Display Pad is desired If slave Display Pads are used we suggest that you disable the IR pass through on those to prevent cross communication 5 2 Zones updated When the desire...

Page 22: ...of the numeric buttons it will enter into a second level of macro function known as HotKeys All the numeric buttons 0 9 can be set up to perform two levels of functions Five buttons at the bottom of t...

Page 23: ...o always go the same source allow individual volume mute and on off capabilities Selecting 0 means the Display Pad is not a member of a group To make a member of one of the groups select SECURITY CODE...

Page 24: ...re automatically added to a macro under the Display Pad s power button When the first zone in the system is turned on all the subsequent source power com mands will be sent to the appropriate equipmen...

Page 25: ...d in the Learning Station Package This will supply the necessary AC power for IR learning and testing 2 CONNECT TO PC Using one of the supplied RS232 cables connect from the RS232 port from your compu...

Page 26: ...indicate that the code has been success fully learned Note that the remote control should be held 8 to 10 inches from the Interface when learning READY POWER Concerto Learning Station Model NV I8DLS P...

Page 27: ...STD E60065 NuVo Technologies Cincinnati Ohio USA FUSE T5 A 120V 60Hz 500W MODEL NV I8DM SIX SOURCE EIGHT ZONE AUDIO DISTRIBUTION SYSTEM www nuvotechnologies com OUTPUT POWER OUTPUT POWER OUTPUT POWER...

Page 28: ...uVo Technologies Cincinnati Ohio USA FUSE T5 A 120V 60Hz 500W MODEL NV I8DM SIX SOURCE EIGHT ZONE AUDIO DISTRIBUTION SYSTEM www nuvotechnologies com OUTPUT POWER OUTPUT POWER OUTPUT POWER 20W 6OHM X2...

Page 29: ...rigger input or from the specific Zone Trigger on the Concerto to the Voltage Trigger on the P2100 as shown in Fig 14 Fig 14 RS232 Interface The RS232 port allows external two way communica tion with...

Page 30: ...E 4 ZONE 5 ZONE 2 PROGRAM 6 4 5 3 1 2 SOURCE STATUS INPUTS R L SENSITIVITY OdBV 1 0RMS 12 6 0 LEFT 6 12 RIGHT 0 AUDIO INPUT 2 INPUT OUTPUT CONTROL SPEAKER MODEL NV P2100 HIGH EFFICIENCY 200 WATT STERE...

Page 31: ...URCE INPUTS ZONE 1 NETWORK EMITTER OUTPUTS DIGITAL LINK ZONE 3 ZONE 4 ZONE 5 ZONE 2 PROGRAM 6 4 5 3 1 2 SOURCE STATUS INPUTS R L SENSITIVITY OdBV 1 0RMS 12 6 0 LEFT 6 12 RIGHT 0 AUDIO INPUT 2 INPUT OU...

Page 32: ...rolling A third possibil ity is that the IR pass through is turned off in the software configuration of the system Reposition the LED end of the emitter on the face of the source equipment so it is fl...

Page 33: ...ard is not completely filled out and mailed within 10 days of the original purchase Power Requirements Power Supply 120VAC 240VAC 50 60Hz Power Consumption all channels 600VA 480W driven to full rated...

Page 34: ...www nuvotechnologies com 4940 Delhi Pike Cincinnati OH 45238 U S A 513 347 2180...

Reviews: