Every device that is connected at the end of the communication data line must be
terminated by either the DIP switch setting or an appropriate device such as a
termination jumper to prevent potential control signal errors.
See Figure 7 for termination switch settings and Figure 8 for examples of devices
requiring termination. Note: Total length of the cable for communication should not
exceed 1.2Km or .74 mile.
SW2 1
2
3
4
Terminated ON
ON
X X
Not terminated
OFF
OFF
X
X
Pull Up/Down **
X
X
ON
ON
Normal **
X
X
OFF
OFF
Figure 7 - Setting Dome Camera Termination
** Unless communication error, put the position 3, 4 of the S1 in OFF state.
Position 3, 4 should be set as a pair. (Both 3, 4 to ON position or OFF position)