SECTION 3 

INSTALLATION PROCEDURE 

3.1  LIFTING AND TRANSPORT  

Because of the heavy weight of the incubator, all lifting and transport must be carried out using 
proper handling equipment. The incubator must be supported from underneath and never turned 
over. 

3.2  UNPACKING 

Remove the packing cardboard box and the second nylon packing around the incubator. The 
below written are  provided with the equipment,  please check them; 
 

  User

”s manual 

  1 piece of warranty certification 

  2  piece of  shelves  

  4  piece of shelf carriers 

  1 piece  of power cable 

 

Check that no damage has occurred during transport

3.3  POSITIONING 

Lift the incubator underneath and carry it carefully to its place.  
Balance  the  incubator  on  four  pedestals.  If  necessary,  provide  stable  standing  by  adjusting  the 
pedestal heights. 
Place the shelf carriers and then the shelves. 
 
Check the followings, 
 

  The proposed site is suitable for the user, 

  The operator can follow up the even he deals with something else. 

  The incubator does not occupy the utilisation space of others or does not damage them. 

  Leave at least 20 cm. free space between the equipment and wall. 

 
ATTENTION !!! 
 

Please pay  special attention  to the followings,  

  

  Indoor  use only  

 

Temperature from 5°C to 40°C  

 

Maximum  relative humidity of 80% for temperature up to 22°C,  

  Maximum  altitude:  2000 m.  

 

The  maximum  performance is obtained between 15°C and 25°C.  

  

 

At  most  70%  of  the  surface  area  of  the  shelves  should  be  used  in  order  to  obtain  a  uniform 
temperature distribution. 

Summary of Contents for EN 300

Page 1: ...0 N VE SANAY MALZEMELER MALAT VE T CARET A EN 300 EN 400 EN 400P EN 500 EN 500P INCUBATORS USER S MANUAL Z14 K25 231 Rev No 05 Rev Date 01 2016...

Page 2: ...ability in the case where the goods are not used in accordance with their proper intent 4 The warranty may not be claimed for damages occurred during the shipment for damages resulting from improper h...

Page 3: ...ove the warning labels do not operate damaged instrument do not operate the instrument with a damaged cable do not move the instrument during operation In case of a problem contact your N ve agent for...

Page 4: ...2 DISPLAY AND CONTROL PANEL 9 4 3 PROGRAMMING SUMMARY 10 4 4 COMPLETION OF THE WORK 11 SECTION 5 11 PERIODIC MAINTENANCE AND CLEANING 11 5 1 PERIODIC MAINTENANCE 11 5 2 CLEANING 11 SECTION 6 11 DISPO...

Page 5: ...n the given tolerances The EN series incubators provide homogeneous temperature distribution by means of the sheet heaters placed onto three outer surfaces of the useful volume The incubator ensures r...

Page 6: ...nternal Dimension WxDxH mm 300x240x300 420x320x360 420x280x360 500x490x500 500x450x500 External Dimension WxDxH mm 555x380x460 705x475x540 700x525x540 780x635x675 790x675x670 Packing Dimension WxDxH m...

Page 7: ...6 2 3 GENERAL PRESENTATION D SPLAY AND CONTROL PANEL SAFETY THERMOSTAT ADJUSTING BUTTON CHAMBER GASKET SHELF ON OFF SWITCH GLASS DOOR HANDLE GLASS DOOR DOOR VENTILATION HOLE SUPPLY INLET POWER CABLE...

Page 8: ...h and carry it carefully to its place Balance the incubator on four pedestals If necessary provide stable standing by adjusting the pedestal heights Place the shelf carriers and then the shelves Check...

Page 9: ...mperature Liquids which may expand during heating do not overflow from their containers The vapours and gases which are generated during the operation are not harmful to humans or flammable or explosi...

Page 10: ...operation 04 Start Stop Key This is the key which is pushed to start the program or to stop the running program 05 Temperature Set Key This key is pushed to set the temperature 06 Temperature Value In...

Page 11: ...temperature display Set the time value by pushing the value increase decrease keys on the time adjustment side 01 minute to 99 hours 54 minutes or Hold Push the time set key again See dly on the tempe...

Page 12: ...CLEANING After unplugging the equipment and the equipment is at the room temperature wipe down the incubator chamber to remove any undesirable effects of the operation for example spillage You may us...

Page 13: ...ective The incubator does not heat check the followings The program is started The safety thermostat is adjusted higher than set temperature 7 1 ERRORS RECOGNISED BY THE MICROPROCESSOR CONTROL SYSTEM...

Page 14: ...13 SECTION 8 ELECTRICAL CIRCUIT DIAGRAM 8 1 EN 300 ELECTRICAL CIRCUIT DIAGRAM...

Page 15: ...14 8 2 EN 400 ELECTRICAL CIRCUIT DIAGRAM...

Page 16: ...15 8 3 EN 500 ELECTRICAL CIRCUIT DIAGRAM...

Page 17: ...16 8 4 EN 400P ELECTRICAL CIRCUIT DIAGRAM...

Page 18: ...17 8 5 EN 500P ELECTRICAL CIRCUIT DIAGRAM...

Page 19: ...18 SECTION 9 WARNING LABEL...

Page 20: ...19 GROUNDED PLUG EN 300 FUSES 2x1A EN 400 EN 400P FUSES 2x 1 6A EN 500 EN 500P FUSES 2x2A...

Reviews: