Table 2. Link Out: Molex Micro-Fit 3.0 Connector
Molex 43025-0400
Manufacturer
Molex Incorporated
Housing
43025-0400
Housing material
Nylon UL94V-0
Circuits
4
Crimp terminal
43030-0002
Wire gauge range
AWG20-24 stranded
Table 3. Link Out Connector Pin Assignment
Pin
Connection
Description
Connected to Device
1
VBUS
DC power from Stack Controller, with Fault
Pilot Signal
Cell Interface
2
COM
Power return from Stack Controller
Cell Interface
3
IPA
Link Bus differential pair plus
Cell Interface
4
IMA
Link Bus differential pair minus
Cell Interface
3.3.2. CAN 485
The CAN 485 connector contains both isolated CAN and non-isolated RS-485 (Modbus) connections.
Isolated CAN requires 5.5-12 Vdc sourced from an external power supply to operate. 120 Ω
termination for CAN is added by connecting pins 3 and 9 together. 150 Ω termination for Modbus is
added by connecting pins 6 and 12 together.
Keep the termination wire length short for best results. Connect external equipment to this connector.
Nuvation Energy High-Voltage BMS - Installation Guide
Document ID: NE-IG-001
6
Rev 2.1, 2020-03-13