17.0 Maintenance
The following list of daily and routine maintenance items is intended as a guide. Refer to LP and HP
Compressor manuals for complete maintenance requirements.
17.1 Daily Maintenance
Be sure to check Compressor Lubricant levels prior to each day of operation. Failure to
ensure the proper lubricant level will lead to system damage.
1) Check lubricant levels of both LP and HP
Compressors and add proper lubricants as
required. See Section 17.3 and Compressor
manuals for details.
2) Slightly open each HP and LP Manual
Condensate
Drain Valve to verify that no condensate is
present.
3) Check LP Air Filtration for condensate and proper
operation of condensate drains.
Use only the specified Nuvair lubricants in this system. The use of
incompatible lubricants presents a risk of fire and/or explosion, and may result
in system damage. This can lead to severe personal injury and death.
Be sure that all pressure has been relieved from the system prior to opening
any filtration canister. Failure to vent pressure from the system prior to opening
the canister can lead to serious personal injury or death.
If system is located in an area where there is high humidity and high heat, the life of all
Filtration Elements may be as little as 35% of rated operating capacity. Check the Compressor
manual and Appendix for details on Filter Element Life Factors.
Condensate
Tank
Filter Pressure
Drain