7.0 Fill Containment Station Specifications
CAUTION
Ambient room temperature should never 113
°
F (45
°
C) during operation of the fill
containment station system. Operation at higher temperatures may lead to system damage
and malfunction.
7.1 Unpacking and Installation
•
Please read all information supplied before physically installing the fill containment station system.
•
Unpack the system and remove from the pallet. Visually inspect the system to make sure there has
been no damage during shipping. If damaged, please call Nuvair to file a damage report. Please take
photos and supply detailed information about the damage.
8.0 Checks for the Start of Each Working Day
Inspect the exterior of the fill containment station (couplings, pipes, pneumatic components, etc.) and check for
any leaks. Replace parts where necessary or contact
Nuvair
.
8.1 Check Refill Hoses
Inspect the refill hoses and make sure there are no cuts, holes, abrasions, leaks etc. If necessary, replace with
new hoses.
8.2 Storing Technical Documentation
The operation manual and any appendices must be stored carefully and must always be kept where they can
be accessed easily for immediate review.
WARNING
This Operation Manual contains important safety information and should always be available
to those personnel operating this equipment. Read, understand, and retain all instructions
before operating this equipment to prevent injury or equipment damage. The Operation Manual
is an integral part of the fill containment station and must always be handed over in the event of a
change in ownership.
Fill Containment Station Series
NSS
Air Quality
CGA Grade E
Maximum Operating Pressure
4500 psi (310 bar)
Structural Hardware
Grade 8 Steel
Protection Between Operator and Cylinders
0.5 in (12.7mm) Steel
Number of Cylinders
2
Dimensions (H x W x D)
59 x 26 x 25 in (150 x 66 x 64 cm)
Weight
560 lb (254 kg)