Pressure Switch: Shuts down the compressor at
a set pressure.
•
Dial-A-Pressure Switch: Allows the operator to
dial in a pressure for the compressor to
automatically shut off at when the pressure is
reached during the filling process.
During refill, the operator must be in the work area. During the tank refill phase, it is advisable to
submerge tanks in cold water to reduce the drop in pressure that accompanies tank cooling.
During tank refill, those not involved in the refill procedure must maintain a safety distance of at least 9
feet (3 meters). Also, it is forbidden to disconnect the hoses from the fittings or the high-pressure out
connection while the machine is under pressure.
Should tanks show evident signs of internal or external corrosion, do not refill them even if they have
been tested.
Use only tested tanks (as proven by a test stamp and/or certificate). The working and tank refill
pressures are stamped on the tanks themselves. It is forbidden to refill them at a pressure greater than
that indicated.
11.0 Maintenance
11.1 Foreword
To obtain the best possible performance from the compressor and ensure a long working life for all its parts it
is essential that personnel follow the use and maintenance instructions with extreme diligence. It is thus
advisable to read the information below and consult the manual every time an inconvenience arises. For
further information please contact Nuvair:
Phone:
+1.805.815.4044
Email:
High-pressure out
connection point
Summary of Contents for MCH60
Page 1: ...Operation Manual MCH60...
Page 2: ...MCH60 Nuvair Page 1 www Nuvair com Notes...
Page 3: ...MCH60 Nuvair Page 2 www Nuvair com Notes...
Page 37: ...MCH60 Nuvair Page 36 www Nuvair com 19 0 Service Log Date Technician Name Service Performed...
Page 41: ...MCH60 Nuvair Page 40 www Nuvair com Notes...