MCH60
Nuvair
Page 26
www.Nuvair.com
Use only the specified Nuvair lubricants in this system. The use of incompatible lubricants presents a
risk of fire and/or explosion and may result in system damage. This can lead to severe personal injury
and death.
Do not carry out these tasks if the compressor has only just shut down; wait for the compressor to
cool. Pressure must be drained before opening LP fill plug.
Any oil spilt during the oil/filter change could cause personnel to slip; wear protective garments and
anti-slip footwear and remove traces of oil immediately.
Both oil and filter are classified as special wastes and must therefore be disposed of in compliance
with the anti-pollution laws in force.
All maintenance work must be carried out with the compressor OFF and the power supply lead
unplugged from the main socket.
11.7 Checking the Oil Level
The compressor must be placed on a solid surface with a
tilt of no more than 15°.
The oil level must be checked every five (5) working hours of
the compressor.
The oil level must be between the minimum
and the maximum shown on the oil level
viewer (left).
If the oil level is above the maximum level:
•
Position a receptacle under the drain hose so that the
oil flows into the exhausted oil receptacle.
•
Open the drain valve and let the oil flow out until the oil
level returns within the maximum and minimum limits.
•
Close the drain valve.
If the oil level is below the minimum level:
•
Open the top fill plug.
•
Top off with oil until the level returns within the
maximum and minimum limits.
•
Close the fill plug.
Lubricant
Fill Plug
Oil Level
Viewer
Oil
Drain Hose