3

1

4

2

1

2

3

New Construction Installation

3

  Snap-in and 

 

Secure Housing

4

  Attach Duct Connector and Ducting

Position Housing  

between joists and  

crimp channel on both  

sides of Mounting Frame  

to lock Housing in place. 

Do not crimp Housing.

Screws from Parts Bag

Top and bottom flanges

go outside Housing

Insert tab into slot

inside Housing

Screw from

Parts Bag

6" to 4" Reducer provided in select models

Tape

Tape

Tape

6" Ducting

4" Ducting

snap!

Summary of Contents for ZN110

Page 1: ...ister your product online at www nutone com register Easy installation in both new construction and retrofit Table of Contents Warnings and Cautions 2 Typical Installation 2 New Construction Installat...

Page 2: ...ies 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 Use only ON OFF switch mechanical t...

Page 3: ...s needed 6 round metal ducting recommended for best performance Use of other ducting is acceptable but may impact performance Roof cap or wall cap built in damper recommended Tape to seal duct connect...

Page 4: ...Ducting Position Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place Do not crimp Housing Screws from Parts Bag Top and bottom flanges go outside Housing...

Page 5: ...ounts to outside of Housing and may be oriented as desired Connect wires LINE IN GRD GRD WHT BLK BLK BLK RED WHT WHT RED MASTER ON OFF SWITCH MASTER ON OFF SWITCH MODE SELECT SWITCH MODE SELECT SWITCH...

Page 6: ...ns Cleaning and Maintenance and Troubleshooting Mask protects unit during construction Remove before installing Grille Install ceiling material Cut out around Housing CAUTION If the blower was unplugg...

Page 7: ...isting wiring to make sure it is not damaged If any damage is found DO NOT CONTINUE INSTALLATION of this product Contact a qualified person s for repair Remove Instruction Sheet Punch out Mask from pa...

Page 8: ...5 1 1 2 3 3 Retrofit Installation 5 Remove Blower Assembly 6 Remove Wiring Panel 7 Insert Mounting Frame Both sides Set aside Blower Assembly Set aside Wiring Panel Set aside screw Bend up four tabs...

Page 9: ...n Step 7 Pull existing wiring into Housing as it is inserted into Mounting Frame Pull existing ductwork into Housing Insert tab into slot inside Housing 10 Attach Ducting and Duct Connector 8 Secure M...

Page 10: ...STER ON OFF SWITCH MODE SELECT SWITCH MODE SELECT SWITCH FAN UNIT SWITCH BOX KNOCKOUT PLATE RECEPTACLE 120 VAC LINE IN SWITCH BOX BLACK WHITE RED GROUND green or bare purchase separately Retrofit Inst...

Page 11: ...iling repairs are needed place Mask in Housing after Blower Assembly is secured See New Construction Installation Step 6 Remove Mask before installing Grille Screws from Parts Bag CAUTION Power must b...

Page 12: ...To Clean For quiet and efficient operation long life and attractive appearance remove Grille and vacuum interior of unit with a dusting brush attachment The Motor is permanently lubricated and never n...

Page 13: ...ontrary to recommendations or instructions e any Fan that has been moved from its original point of installation f damage caused by environmental or natural elements g damage in transit h natural wear...

Page 14: ...ZN80 n ZN110 Installation Guide Page 14 99045092B...

Page 15: ...su producto en l nea en el sitio www nutone com register Instalaci n sencilla tanto en construcciones nuevas como en modernizaciones Tabla de contenido Advertencias y precauciones 2 Instalaci n t pica...

Page 16: ...6 Los ventiladores conectados a conductos siempre deben tener ventilaci n hacia el exterior 7 Use solamente un interruptor de ENCENDIDO APAGADO un temporizador mec nico o un control de rel interrupto...

Page 17: ...tornillador de cabeza plana Pinza Pelacable para la aislaci n de los cables Pinza cortacable Materiales necesarios Conducto circular de metal de 6 pulg recomendado para un mejor rendimiento Se acepta...

Page 18: ...l a ambos lados del bastidor de montaje para que el compartimiento quede asegurado en su lugar No ajuste el compartimiento Pernos de la bolsa de piezas Las bridas superior e inferior deben ir por fuer...

Page 19: ...ON OFF INTERRUPTOR DE LA SELECCI N DE MODO INTERRUPTOR DE LA SELECCI N DE MODO VENTILADOR UNIDAD TABLERO EL CTRICO PLACA MET LICA RECEPT CULO EN L NEA DE 120 VCA TABLERO EL CTRICO comprar por separad...

Page 20: ...iento e Identificaci n y soluci n de fallas La m scara protege la unidad durante la construcci n Ret rela antes de instalar la rejilla Instale el material del techo Corte alrededor del compartimiento...

Page 21: ...nar alg n da o NO CONTIN E CON LA INSTALACI N de este producto Comun quese con la s persona s calificada s para realizar la reparaci n Retire la hoja de instrucciones Retire la m scara del envase Cons...

Page 22: ...zaciones 5 Retire el conjunto del ventilador 6 Retire el panel con los cables 7 Introduzca el bastidor de montaje Ambos lados Aparte el conjunto del ventilador Aparte el panel con los cables Aparte el...

Page 23: ...n el bastidor de montaje Introduzca el conducto existente en el compartimiento Introduzca la pesta a en la ranura que se encuentra en el interior del compartimiento 10 Fije el conector del conducto y...

Page 24: ...ije las abrazaderas de los cables a la placa met lica La placa met lica debe montarse en el interior del compartimiento y se la puede ubicar en la orientaci n deseada Conecte los cables Perno apartado...

Page 25: ...cho coloque la m scara en el compartimiento despu s de asegurar el conjunto del ventilador Consulte el Paso 6 de Instalaci n en una construcci n nueva Retire la m scara antes de instalar la rejilla Pe...

Page 26: ...necte el interruptor principal Limpieza y mantenimiento Limpieza Para un funcionamiento silencioso y eficiente una vida til prolongada y una atractiva apariencia retire la rejilla y aspire el interior...

Page 27: ...adado del punto original de instalaci n f da o provocado por elementos naturales o ambientales g da o durante el transporte h desgaste natural del acabado i Ventiladores en uso comercial o no residenc...

Page 28: ...ZN80 n ZN110 Gu a para la instalaci n P gina 14 99045092B...

Reviews: