2. Attach 

damper/duct

connector.

Snap damper / 

duct connector 

onto housing. 

Make sure con-

nector is flush with 

top of housing and 

damper flap falls 

closed.

3. Install 

4-inch 

round duct-

work.

Connect 4-inch 

round ductwork 

to damper / duct 

connector. Run 

ductwork to a 

roof cap or wall 

cap. Tape all 

ductwork con-

nections to make 

them secure and air tight.

INSTALL HOUSING & DUCT

1a. Mount 

housing to 

joist or 

I

-joist.

Use a pliers to bend 

housing

TABS out 

to 90

0

. Hold housing 

in place so that 

the housing tabs 

contact the bottom 

of the joist. The 

housing mounts 

with four (4) screws 

or nails. Screw or 

nail housing to joist 

through lowest 

holes in each 

mounting flange,  

then through 

highest holes. 

NOTE: Mounting to 

I

-JOIST (shown) 

requires use 

of

SPACERS

(included) between 

the highest hole 

of each mounting 

flange and the 

I

-joist.

SPACER

(use for mounting to I-Joist)

I

-JOIST

TABS

1b. Mount housing anywhere between 

trusses, joists, or 

I

-joists using hanger 

bars.

Sliding hanger bars are provided to allow for accurate posi-

tioning of housing anywhere between framing. They can be 

used on all types of framing (

I

-joist, standard joist, and truss 

construction) and span up to 24”.

Attach the MOUNTING CHANNELS to the housing using the 

SCREWS supplied. Make sure TABS face “up” as shown. Use 

the set of channel mounting holes (marked “STD”) to mount the 

housing flush with the bottom of the drywall. Use the other set 

of holes (not marked) to mount the housing flush with the top of 

the drywall.

OR

HANGER

BAR (4)

SCREWS (4)

TAB

Extend HANGER BARS to the width of the framing.
Hold ventilator in place with the hanger bar tabs wrapping 

around the BOTTOM EDGE OF THE FRAMING.

 NAIL ventilator to framing or fasten with screws (not provided) 

through HOLES near nails.

*

 To ensure a noise-free mount: Secure hanger bars together 

with SCREWS or use a pliers to crimp mounting channels 

tightly around hanger bars.

HOLE FOR OPTIONAL 

SCREW MOUNTING (4)

STD

MOUNTING

CHANNEL (2)

NAIL (4)

BOTTOM EDGE 

OF FRAMING

*

SCREW (2)

Summary of Contents for ULTRA SILENT QTRN Series

Page 1: ...replace the blower assembly includes motor and impeller OPERATION Use an on off switch or speed control to operate this ventilator See Connect Wiring for details Use of speed controls other than the N...

Page 2: ...line voltage and appropriate power cable Housing mount ed anywhere between I joists using hanger bars Housing mount ed to joists Housing mount ed anywhere between joists using hanger bars Housing moun...

Page 3: ...b Mount housing anywhere between trusses joists or I joists using hanger bars Sliding hanger bars are provided to allow for accurate posi tioning of housing anywhere between framing They can be used o...

Page 4: ...motor Remove thumbscrew 11 from motor plate flange Find the single TAB on the motor plate located next to the receptacle Push up near motor plate tab while pushing out on side of housing Or insert a...

Page 5: ...con el accesorio del cepillo para sacudir polvo El motor est permanentemente lubricado y nunca necesitar aceite Si los cojinetes del motor est n haciendo ruido excesivo o inusual reemplace el conjunto...

Page 6: ...requiera el tramo de conducto m s corto posible y un m nimo n mero de codos Instale una tapa de techo o de pared que tenga un regulador de tiro incorporado a fin de reducir los contratiros Alimente l...

Page 7: ...de montaje del canal marcados como STD para montar la cubierta al ras con la parte inferior de la tablarroca Utilice el otro juego de orificios sin marca para montar la cubierta al ras con la parte su...

Page 8: ...no el n mero de la clave 99044373C NOTA DE SERVICIO Para desmontar el conjunto del ven tilador Desenchufe el motor Saque el tornillo de mariposa 11 de la brida de la placa del motor Localice la LENG...

Reviews: