background image

RN80 

n

 RN110 Installation Guide

Page 13

5

10

1

3

6

7

4

8

9

2

Service Parts

Order replacement 

parts by

 Part No.

not by 

Key No.

  Key No.   Part No. 

Description

 

97018349  Mounting Frame

 

97018721  Knockout Plate & Screws

  3 

97018382 Housing

 

97018447  Wiring Panel/Harness Assembly 

 

97019405  Blower Assembly 

(RN80)

 

 

97019406  Blower Assembly 

(RN110)

 

  6 

97019520 Flange

  7 

97019466 Transition

  8 

97019565 Muffler

 

97018532  Grille Assembly 

(includes 10)

  10 

99140208  Grille Spring 

(2 req’d)

Warranty

NuTone Ventilation Fans Limited Warranty

WARRANTY PERIOD: NuTone warrants to the original consumer purchaser of 

its NuTone Ventilation Fans (the “Fan”) that your Fan will be materially free from 

defects in materials or workmanship for a period of three (3) years from the date 

of original purchase. This warranty does not cover accessories, such as speed 

controls, that may be purchased separately and installed with the Fan.

The limited warranty period for replacement parts, and for Fans repaired or 

replaced under this limited warranty, shall continue for the remainder of the 

original warranty period.

NO OTHER WARRANTIES: THE FOREGOING WARRANTIES ARE 

EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR 

IMPLIED. NUTONE DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS 

WARRANTIES, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES 

IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF 

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. TO 

THE EXTENT THAT APPLICABLE LAW PROHIBITS THE EXCLUSION OF 

IMPLIED WARRANTIES, THE DURATION OF ANY APPLICABLE IMPLIED 

WARRANTY IS LIMITED TO THE PERIOD SPECIFIED FOR THE EXPRESS 

WARRANTY. Some states do not allow limitations on how long an implied 

warranty lasts, so the above limitation may not apply to you. Any oral or written 

description of the Fan is for the sole purpose of identifying it and shall not be 

construed as an express warranty.

REMEDY: During the applicable limited warranty period, NuTone will, at its 

option, provide replacement parts for, or repair or replace, without charge, 

any Fan or part thereof, to the extent NuTone finds it to be covered by and in 

breach of this limited warranty. NuTone will ship the repaired or replaced Fan 

or replacement parts to you at no charge. You are responsible for all costs for 

removal, reinstallation and shipping, insurance or other freight charges incurred 

in the shipment of the Fan or part to NuTone. This warranty does not cover (a) 

normal maintenance and service, (b) normal wear and tear, (c) any Fans or 

parts which have been subject to misuse, abuse, abnormal usage, negligence, 

accident, improper or insufficient maintenance, storage or repair (other than 

repair by NuTone), (d) damage caused by faulty installation, or installation or 

use contrary to recommendations or instructions, (e) any Fan that has been 

moved from its original point of installation, (f) damage caused by environmental 

or natural elements, (g) damage in transit, (h) natural wear of finish, (i) Fans in 

commercial or nonresidential use, or (j) damage caused by fire, flood or other 

act of God. This warranty covers only Fans sold in the United States or through 

U.S. distributors authorized by NuTone. 

EXCLUSION OF DAMAGES: NUTONE’S OBLIGATION TO PROVIDE 

REPLACEMENT PARTS, OR REPAIR OR REPLACE, AT NUTONE’S 

OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER 

THIS LIMITED WARRANTY AND NUTONE’S SOLE AND EXCLUSIVE 

OBLIGATION. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, 

INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT 

OF OR IN CONNECTION WITH THE FAN, ITS USE OR PERFORMANCE. 

Incidental damages include but are not limited to such damages as loss of time 

and loss of use. Consequential damages include but are not limited to the cost 

of repairing or replacing other property which was damaged if the Fan does not 

work properly. 

Some states do not allow the exclusion or limitation of incidental or 

consequential damages, so the above limitation or exclusion may not apply to 

you. This warranty gives you specific legal rights, and you may also have other 

rights, which vary from state to state. 

This warranty supersedes all prior warranties and is not transferable from the 

original consumer purchaser. 

NUTONE SHALL NOT BE LIABLE TO YOU, OR TO ANYONE CLAIMING 

UNDER YOU, FOR ANY OTHER OBLIGATIONS OR LIABILITIES, 

INCLUDING, BUT NOT LIMITED TO, OBLIGATIONS OR LIABILITIES 

ARISING OUT OF BREACH OF CONTRACT OR WARRANTY, NEGLIGENCE 

OR OTHER TORT OR ANY THEORY OF STRICT LIABILITY, WITH RESPECT 

TO THE FAN OR NUTONE’S ACTS OR OMISSIONS OR OTHERWISE. 

This warranty covers only replacement or repair of defective Fans or parts 

thereof at NuTone’s main facility and does not include the cost of field service 

travel and living expenses.

Any assistance NuTone provides to or procures for you outside the terms, 

limitations or exclusions of this limited warranty will not constitute a waiver of 

such terms, limitations or exclusions, nor will such assistance extend or revive 

the warranty.

NuTone will not reimburse you for any expenses incurred by you in repairing or 

replacing any defective Fan, except for those incurred with NuTone’s prior written 

permission.

HOW TO OBTAIN WARRANTY SERVICE:

 To qualify for warranty service, you 

must (a) notify NuTone at the address or telephone number stated below within 

seven (7) days of discovering the covered defect, (b) give the model number 

and part identification and (c) describe the nature of any defect in the Fan or 

part. At the time of requesting warranty service, you must present evidence of 

the original purchase date. 

Broan-NuTone LLC, 926 West State Street, Hartford, WI  53027  

(1-888-336-6151)

www.nutone.com

If you must send the Fan or part to NuTone, as instructed by NuTone, you must 

properly pack the Fan or part—NuTone is not responsible for damage in transit.

Summary of Contents for Ultra Pro RN110

Page 1: ...e with homeowner Register your product online at www nutone com register Easy installation in both new construction and retrofit Table of Contents Warnings and Cautions 2 Typical Installation 2 New Co...

Page 2: ...ring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be c...

Page 3: ...with a Phillips bit Phillips screwdriver Flathead screwdriver Pliers Wire insulation stripper Wire cutter Materials needed 4 round metal ducting recommended for best performance Use of other ducting i...

Page 4: ...ge Transition and Ducting Position Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place Do not crimp Housing Screws from Parts Bag Top and bottom flanges g...

Page 5: ...Parts Bag Attach cable clamp to Knockout Plate Knockout Plate mounts to outside of Housing and may be oriented as desired Connect wires LINE IN GRD WHT BLK GRD WHT BLK BLK ON OFF SWITCH purchase sepa...

Page 6: ...tion 6 Insert Mask and Finish Ceiling 7 Install Grille See Page 12 for Operation Cleaning and Maintenance and Troubleshooting Mask protects unit during construction Remove before installing Grille Tap...

Page 7: ...isting wiring to make sure it is not damaged If any damage is found DO NOT CONTINUE INSTALLATION of this product Contact a qualified person s for repair Remove Instruction Sheet Punch out Mask from pa...

Page 8: ...4 5 1 2 3 2 Retrofit Installation 5 Remove Blower Assembly 6 Remove Wiring Panel 7 Insert Mounting Frame Both sides Set aside Blower Assembly Set aside Wiring Panel Set aside screw Bend up four tabs R...

Page 9: ...ws set aside in Step 7 Pull existing wiring into Housing as it is inserted into Mounting Frame Pull existing ductwork into Housing Insert tab into slot inside Housing 10 Attach Flange Transition and D...

Page 10: ...GRD WHT BLK GRD WHT BLK BLK ON OFF SWITCH purchase separately FAN WHT UNIT SWITCH BOX KNOCKOUT PLATE RECEPTACLE 120 VAC LINE IN SWITCH BOX BLACK WHITE GROUND green or bare ON OFF SWITCH LINE IN GRD W...

Page 11: ...trofit Installation 12 Insert and Secure Blower Assembly and Muffler 13 Install Grille Screws from Parts Bag Attach Muffler If ceiling repairs are needed tape Mask into Housing See New Construction In...

Page 12: ...remove Grille and vacuum interior of unit with a dusting brush attachment The Motor is permanently lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replac...

Page 13: ...has been moved from its original point of installation f damage caused by environmental or natural elements g damage in transit h natural wear of finish i Fans in commercial or nonresidential use or j...

Page 14: ...RN80 n RN110 Installation Guide Page 14 99045219C...

Page 15: ...istre su producto en l nea en el sitio www nutone com register Instalaci n sencilla tanto en construcciones nuevas como en modernizaciones Tabla de contenido Advertencias y precauciones 2 Instalaci n...

Page 16: ...7 Si se va a instalar esta unidad sobre una tina o ducha debe marcarse que es apropiada para esta aplicaci n y conectarse a un GFCI interruptor accionado por p rdida de conexi n a tierra en un circui...

Page 17: ...tornillador de cabeza plana Pinza Pelacable para la aislaci n de los cables Pinza cortacable Materiales necesarios Conducto circular de metal de 4 pulg recomendado para un mejor rendimiento Se acepta...

Page 18: ...las vigas y ajuste el canal a ambos lados del bastidor de montaje para que el compartimiento quede asegurado en su lugar No ajuste el compartimiento Pernos de la bolsa de piezas Las bridas superior e...

Page 19: ...MET LICA RECEPT CULO EN L NEA DE 120 VCA TABLERO EL CTRICO INTERRUPTOR DE ENCENDIDO APAGADO ON OFF NEGRO BLANCO CONEXI N A TIERRA verde o sin protecci n Instalaci n en una construcci n nueva 5 Conect...

Page 20: ...techo 7 Instale la rejilla Consulte la p gina 12 sobre Funcionamiento Limpieza y mantenimiento e Identificaci n y soluci n de fallas La m scara protege la unidad durante la construcci n Ret rela antes...

Page 21: ...nar alg n da o NO CONTIN E CON LA INSTALACI N de este producto Comun quese con la s persona s calificada s para realizar la reparaci n Retire la hoja de instrucciones Retire la m scara del envase Cons...

Page 22: ...aciones 5 Retire el conjunto del ventilador 6 Retire el panel con los cables 7 Introduzca el bastidor de montaje Ambos lados Aparte el conjunto del ventilador Aparte el panel con los cables Aparte el...

Page 23: ...to mientras lo introduce en el bastidor de montaje Introduzca el conducto existente en el compartimiento Introduzca la pesta a en la ranura que se encuentra en el interior del compartimiento 10 Fije e...

Page 24: ...CTRICO PLACA MET LICA RECEPT CULO EN L NEA DE 120 VCA TABLERO EL CTRICO INTERRUPTOR DE ENCENDIDO APAGADO ON OFF NEGRO BLANCO CONEXI N A TIERRA verde o sin protecci n Instalaci n en modernizaciones 11...

Page 25: ...2 Introduzca y asegure el conjunto del ventilador y el mofle 13 Instale la rejilla Pernos de la bolsa de piezas Fije el mofle Si se necesitan reparaciones de techo cinta del mofle en el compartimiento...

Page 26: ...re la rejilla y aspire el interior de la unidad con un accesorio en forma de cepillo para eliminar el polvo El motor siempre permanecer lubricado y no ser necesario agregarle aceite Si los cojinetes d...

Page 27: ...ientales g da o durante el transporte h desgaste natural del acabado i Ventiladores en uso comercial o no residencial o j da o provocado por incendio inundaci n u otro caso fortuito Esta garant a cubr...

Page 28: ...RN80 n RN110 Gu a para la instalaci n P gina 14 99045219C...

Reviews: