MODELS   QTREN080FLT • QTREN110FLT  

TYPICAL INSTALLATIONS

Housing mounted to I-joists.

Housing mounted anywhere 

between trusses using hanger 

bars.

PLAN THE INSTALLATION

The unit will operate most quietly and efficiently when located 
where the shortest possible duct run and minimum number 
of elbows will be needed.
Use a roof cap or wall cap that has a built-in damper to 
reduce backdrafts.
Plan to supply the unit with proper line voltage and appropri-
ate power cable.

Housing mounted anywhere be-

tween I-joists using hanger bars.

Housing mounted to joists.

Housing mounted anywhere be-

tween joists using hanger bars.

Housing mounted anywhere be-

tween trusses using hanger bars.

INSTALL HOUSING & DUCT

1a. Mount 

housing 

to joist or 

I

-joist.

Use a pliers to 

bend housing 

TABS out 

to 90

0

. Hold 

housing in 

place so that 

the housing 

tabs contact 

the bottom 

of the joist. 

The housing 

mounts with 

four (4) screws 

or nails. Screw 

or nail housing 

to joist through 

lowest holes in 

each mounting 

flange,  then 

through 

highest holes. 

SPACER

(use for mounting to I-Joist)

I

-JOIST

NOTE: Mounting to 

I

-JOIST (shown) requires use of 

SPACERS (included) between the highest hole of 

each mounting flange and the 

I

-joist.

OR

Cooking

Equipment

Floor

COOKING AREA

Do not install above or

inside this area.

45

o

45

o

NOT FOR USE IN

A COOKING AREA.

TABS

*Purchase

separately.

INSULATION* 

(Place around and 

over Fan Housing.)

ROOF CAP*

(with built-in

damper)

FAN

HOUSING

POWER

CABLE*

4-IN. ROUND

DUCT*

4-IN.

ROUND

ELBOWS*

Seal gaps

around

Housing.

Seal duct

joints with

tape.

OR

Keep duct

runs short.

   WALL CAP* 

(with built-in

damper)

Summary of Contents for QTREN080FLT

Page 1: ...e fan light and night light can be operated separately Use a 3 function wall control Do not use a dimmer switch to operate the light See Connect Wiring for details Use of speed controls other than the...

Page 2: ...HOUSING DUCT 1a Mount housing to joist or I joist Use a pliers to bend housing TABS out to 900 Hold housing in place so that the housing tabs contact the bottom of the joist The housing mounts with f...

Page 3: ...drywall Use the other set of holes not marked to mount the housing flush with the top of the drywall HANGER BAR 4 SCREWS 4 TAB Extend HANGER BARS to the width of the framing Hold ventilator in place w...

Page 4: ...mall flat blade screwdriver between grille and lens Pry lens out 7 Push grille against ceiling 9 Install light bulbs Fluorescent bulbs supplied Purchase a 4W incandescent night light bulb Insert bulbs...

Page 5: ...do ruido excesivo o inusual reemplace el conjunto del ventilador incluye el motor y el rodete del ventilador OPERACI N El ventilador la l mpara y la l mpara de noche pueden funcionar separadamente Uti...

Page 6: ...un alicate doble las LENG ETAS de la cubierta a 90 Sostenga la cubierta en su lugar de manera que las leng etas de la cubierta hagan contacto con la parte inferior de la vigueta Para el montaje de la...

Page 7: ...marca para montar la cubierta al ras con la parte superior de la tablarroca BARRA DE SUS PENSI N 4 TORNILLOS 4 LENG ETA STD CANAL DE MONTAJE 2 Abra las BARRAS DE SUSPENSI N hasta el ancho de la estruc...

Page 8: ...pedido de una pieza de servicio se debe especificar el n mero de la pieza no el n mero de la clave NOTA DE SERVICIO Para desmontar el conjunto del ventilador Desenchufe el motor Saque el tornillo de...

Reviews: