SERVICE PARTS
99044907B
SERVICE NOTE
To remove Blower
Assembly:
Unplug motor.
Remove
thumbscrew (10)
from motor plate
flange.
Find the single
TAB on the motor
plate (located next
to the receptacle).
Push up near
motor plate tab
while pushing
out on side of
housing. Or insert
a straight-blade
screwdriver into
slot in housing
(next to tab) and
twist screwdriver.
9. Remove
light lens.
Carefully insert a
small flat-blade
screwdriver
between grille
and lens. Pry
lens out.
8. Push grille
against
ceiling.
Replacement parts can
be ordered on our web-
site. Please visit us at
www.nutone.com
Key No. Part No.
Description
1
97016466 Housing
2
97016449 Duct Connector - 4”
3
98010102 Wiring Plate
4
99170245 Screw, #8-18 X .375
5
97018011 Wire Panel/Harness Assembly
6
97018218 Blower Assembly
7
97017775 Grille Assembly (includes key nos. 8 & 9)
8
99140199 Grille Spring (2 req’d)
9
99111400 Lens
10
99420665 Thumbscrew, #8-18 x .375
11
97018014 Spacer (2 supplied)
12
99271381 Bulb, GU24, 18W Fluorescent (2 req.)
Order service parts by “Part No.” - not by “Key No.”
10. Install light
bulbs.
Product includes
(2) 18W (max.),
type GU24
fluorescent
lamps with
M.O.L.
(maximum
overall length) of
3.9” (100mm) as
illustrated below.
Purchase a 4W
(max.), type C7
incandescent
night light bulb.
Insert lamps and
bulb into their
sockets. Replace lens.