WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 
or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a

qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.

4.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment 
manufacturer’s guideline and safety standards such as those 
published by the National Fire Protection Association (NFPA), 
and the American Society for Heating, Refrigeration and Air 
Conditioning Engineers (ASHRAE), and the local code authori-
ties.

5. When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.

7.  Acceptable for use over a tub or shower when connected to 

a GFCI (Ground Fault Circuit Interrupter) - protected branch 
circuit (ceiling installation only).

8.  This unit must be grounded.

CAUTION  

1.  For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2. This product is designed for installation in ceilings up to a 

12/12 pitch (45 degree angle). Duct connector must point up. 
DO NOT MOUNT THIS PRODUCT IN A WALL.

3.  To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power 
unit.

4.  Please read specification label on product for further informa-

tion and requirements.

MODEL QT110E
VENTILATION FAN

READ AND SAVE THESE INSTRUCTIONS

WARRANTY

Installer: Leave this manual with the homeowner.

OPERATION

Use an on/off switch or solid-state speed control to operate this 
ventilator. See “Connect Wiring” for details.

To register this product visit:

www.broan.com

CLEANING & MAINTENANCE

For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the 
dusting brush attachment.

The motor is permanently lubricated and never needs oiling. If the 
motor bearings are making excessive or unusual noises, replace 
the blower assembly (includes motor and impeller).

BROAN-NUTONE THREE YEAR LIMITED WARRANTY

Broan-NuTone warrants to the original consumer purchaser of its products that 
such products will be free from defects in materials or workmanship for a period 
of three years from the date of original purchase. THERE ARE NO OTHER 
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED 
TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A 
PARTICULAR PURPOSE.

During this three-year period, Broan-NuTone will, at its option, repair or replace, 
without charge, any product or part which is found to be defective under normal 
use and service.

THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, 
TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, 
ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. 
This warranty does not cover (a) normal maintenance and service or (b) any 
products or parts which have been subject to misuse, negligence, accident, 
improper maintenance or repair (other than by Broan-NuTone), faulty installation 
or installation contrary to recommended installation instructions.

The duration of any implied warranty is limited to the three-year period as specified 
for the express warranty. Some states do not allow limitation on how long an 
implied warranty lasts, so the above limitation may not apply to you.

BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-
NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE 
REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE 
FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING 
OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. 
Some states do not allow the exclusion or limitation of incidental or consequential 
damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights, 
which vary from state to state. This warranty supersedes all prior warranties.

To qualify for warranty service, you must (a) notify Broan-NuTone at the address or 
telephone number below, (b) give the model number and part identification and (c) 
describe the nature of any defect in the product or part. At the time of requesting 
warranty service, you must present evidence of the original purchase date.

Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027
www.broan.com    888-336-3948

Summary of Contents for QT110

Page 1: ...long life and attractive appear ance lower or remove grille and vacuum interior of unit with the dusting brush attachment The motor is permanently lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the blower assembly includes motor and impeller BROAN NUTONE THREE YEAR LIMITED WARRANTY Broan NuTone warrants to the original consumer purchaser of i...

Page 2: ...s Housing mounted to truss To mount housing anywhere between joists i joists or trusses use optional hanger bar kit QTHB1 sold separately Follow mounting instructions included with kit ROOF CAP with built in damper WALL CAP with built in damper 4 IN ROUND ELBOWS 4 IN ROUND DUCT FAN HOUSING Seal gaps around housing Seal duct joints with tape Keep duct runs short INSULATION Place around and over fan...

Page 3: ... damper duct connector Run ductwork to a roof cap or wall cap Tape all ductwork connections to make them secure and air tight INSTALL HOUSING DUCT 1 Bend housing tabs Use a pliers to bend housing TABS out to 900 2 Mount housing to joist Hold housing in place so that the housing tabs contact the bottom of the joist The hous ing mounts with four 4 screws or nails Screw or nail housing to joist throu...

Page 4: ...queeze grille springs and insert them into slots on each side of hous ing 8 Push grille against ceiling 6 Finish ceiling Install ceiling material Cut out around housing SERVICE NOTE To remove Blower Assembly Unplug motor Remove thumbscrew 10 from motor plate flange Find the single TAB on the motor plate located next to the receptacle Push up near motor plate tab while pushing out on side of housin...

Page 5: ...onexión eléctrica Para registrar este producto visite www broan com MODELO QT110E VENTILADOR LIMPIEZA Y MANTENIMIENTO Para lograr un funcionamiento silencioso y eficiente como tam bién larga vida y una apariencia atractiva baje o retire la rejilla y aspire el interior de la unidad con el accesorio del cepillo para sacudir polvo El motor está permanentemente lubricado y nunca necesitará aceite Si l...

Page 6: ...ualquier parte entre las vigu etas i vigas o armaduras utilice el kit opcional de barra de sus pensión QTHB1 se vende por separado Siga las instrucciones de montaje incluido con el kit TAPA DE TECHO con amortiguador integral TAPA DE PARED con amortiguador integral CODO REDONDO DE 4 PULG CONDUCTO REDONDO DE 4 PULG CUBIERTA DE VENTILADOR Selle los huecos alrededor de la cubierta Sellar las juntas co...

Page 7: ...gulador caiga cerrada 4 Instale el conducto redondo de 4 pulgadas Conecte el con ducto redondo de 4 pulgadas al conec tor del regulador conducto Extienda el conducto hacia una tapa de techo o tapa de pared Encinte todas las conexiones de los conductos para fijarlas y hacerlas herméticas al aire 2 Monte la cubierta en la vigueta Sostenga la cubi erta en su lugar de manera que las lengüetas de la cu...

Page 8: ...e la placa del motor 9 Localice la LENGÜETA única de la placa del motor se encuentra junto al receptáculo Empuje hacia arriba cerca de la lengüeta de la placa del motor al mismo tiempo que empuja hacia afuera el costado de la cubierta O bien introduzca un destornillador de punta recta en la ranura de la cubierta junto a la lengüeta y gírelo 7 Acople la rejilla a la cubierta Apriete los resortes de...

Reviews: