PLANNING - 

(continued)

Note: 

The high level of air flow of this appliance may affect the gas

flame on some types of gas cooktops. This is NORMAL and will
cause no harm, but can be corrected by lowering the speed of the
blower.

Pay special attention to the areas of potential interference high-
lighted above. A countertop with (A) a raised lip and/or (B) a
backsplash may not allow enough flat countertop for a proper
installation. Note that 2" of flat countertop is required behind
cooktop and that 1-3/4" is necessary between the back edge of the
cooktop and the inside of cabinet back.

SPECIFICATIONS

VOLTS AMPS

CFM

DUCT

120

4.0

500

3-1/4 x 10

PLAN THE DUCTWORK

2

TAKE MEASUREMENTS

1. Refer to the cooktop installation instructions for dimensions of

cooktop, countertop cut-out, and cabinet requirements. The
Model 2730 will fit in most 30" wide cabinets and the Model
2736 will fit in most 36" wide cabinets. However, it is recom-
mended that oversized cabinets be used for easier installa-
tion.

2. Cooktop depth can vary greatly from one to another. This may

cause the fit of these two appliances to be rather tight.

3. The system will operate most efficiently when the ductwork

does not exceed 40 feet of equivalent duct. The chart, above,
shows equivalent feet of elbows and transitions. The number
of feet of straight duct plus the equivalent feet of transitions
and/or elbows to be used should equal 40 feet or less.

NOTE: The equivalent feet of various roof and wall caps has
been taken into consideration. Do not include them in this
calculation.

PLAN THE WIRING

1. The downdraft and exterior blower system draws 4 AMPS and

requires a 120 VAC, 60 Hz circuit.

2. Plan to provide unit with grounded wiring which meets codes:

Note: Installations in which the fit between blower system and
cabinet is tight. 

Consider running the wiring through a adjacent

cabinet to prevent sharp bends in wiring.

EQUALS 6 FT. OF
STRAIGHT DUCT

8" ROUND
ELBOW

3-1/4" X 10"
TO 6" RD.
TRANSITION

3-1/4" X 10"
90

O

 ELBOW

EQUALS 8
FT. OF
STRAIGHT DUCT

EQUALS 2
FT. OF
STRAIGHT DUCT

1. This downdraft blower system is designed for use with 3 " x

10" ductwork (can be transitioned to 6" round). Three different
discharge directions are available with side-to-side adjust-
ment for accurate alignment of ductwork.

2. For best performance: Choose the ducting option which allows

the shortest length of ductwork and a minimum number of
elbows and transitions. Check location of floor joists, wall
studs, electrical wiring or plumbing for possible interference.
NOTE: The unit is shipped with the 3 " x 10" discharge facing
DOWN. See "CHANGING BLOWER DIRECTION" on page 3,
if necessary.

RIGHT
DISCHARGE

DOWN'
DISCHARGE
(as shipped)

LEFT
DISCHARGE

Summary of Contents for ECLIPSE 2730

Page 1: ...gnite Heat oils slowly on low or medium settings 2 Always turn hood ON when cooking at high heat or when cooking flaming foods 3 Cleanventilatingfansfrequently Greaseshouldnotbeallowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FO...

Page 2: ...lent feet of elbows and transitions The number of feet of straight duct plus the equivalent feet of transitions and or elbows to be used should equal 40 feet or less NOTE The equivalent feet of various roof and wall caps has been taken into consideration Do not include them in this calculation PLAN THE WIRING 1 The downdraft and exterior blower system draws 4 AMPS and requires a 120 VAC 60 Hz circ...

Page 3: ...m flange may have to face inward in tight cabinet installations 2 Secure the downdraft to the countertop as follows Hold the downdraft against the back of countertop cut out and tighten ing the 2 mounting screws one on each end of unit on underside of countertop Use a wood shim between screws and underside of granite countertops 3 Screw leveling brackets to bottom of cabinet Tighten screws holding...

Page 4: ...eft or right to meet ductwork Re tighten screws and nuts Note A 3 1 4 x 10 collar is provided for installers who prefer to rivet the ductwork to the unit This will allow blower to be removed and replaced easily in service situations without disturbing duct work INSTALL ELECTRICAL WIRING 6 RD ELBOW DUCT WORK 3 1 4 X 10 TO 6 RD TRANSITION BLOWER COLLAR SCREWS 4 WARNING To avoid possible electrical s...

Page 5: ...urn the cooktop off This will keep the whole kitchen cleaner and brighter Turn the downdraft blower ON by pressing down on the activating switch The air vent will rise The blower can be turned ON or OFF and its speed can be adjusted with the recessed knob on the right side of the air vent Turn the downdraft blower OFF by pressing the activating switch again The air vent will go down and the blower...

Page 6: ...30080131 Motor with Capacitor Key No 73 1 21 30020081 Blower Wheel 1 33 RF30A Filter Kit Model 2730 contains 2 filters 1 RF36A Filter Kit Model 2736 contains 2 filters 1 46 30080423 Gearmotor 1 73 30840114 Capacitor 1 Models 2730 2736 Downdraft Blower Systems OPTIONAL DOOR KITS MODEL NO DESCRIPTION 273001C 30 White 273023C 30 Black 273601C 36 White 273623C 36 Black SERVICE PARTS ...

Page 7: ...SERVICE PARTS 75 7 84 Models 2730 2736 Downdraft Blower Systems ...

Page 8: ...o not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE LLC S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE LLC S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE LLC SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFOR...

Reviews: