background image

®

Page 6

ALLURE™   WS1 SERIES

RANGE HOOD

626976B

WARRANTY

NUTONE ONE YEAR LIMITED WARRANTY

NuTone  warrants to the original consumer purchaser of its products that such products
will be free from defects in materials or workmanship for a period of one year from the
date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MER-
CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, NuTone will, at its option, repair or replace, without charge,
any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS
AND TUBES. This warranty does not cover (a) normal maintenance and service or (b)
any products or parts which have been subject to misuse, negligence, accident, improper
maintenance or repair (other than by NuTone), faulty installation or installation contrary
to recommended installation instructions.
The duration of an implied warranty is limited to the one-year period as specified for the
express warranty. Some states do not allow limitation on how long an implied warranty
lasts, so the above limitation may not apply to you.
NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION,
SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS
WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSE-
QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION
WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclu-
sion or limitation of incidental or consequential damages, so the above limitation may not
apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which
vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify NuTone at the address or telephone
number below, (b) give the model number and part identification and (c) describe the
nature of any defect in the product or part. At the time of requesting warranty service, you
must present evidence of the original purchase date.

NuTone, Inc.,

 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)

SERVICE PARTS

KEY NO.

PART NO.

DESCRIPTION

1

R680508

7” Round Duct Plate (includes hardware)

2

R740013

Damper/Duct Connector 

(includes hardware)

3

R602017

Screw, #8-18 x ¼ Hex* (2  in package)

4

R561115

Rocker Switch, Almond (2  in package)

R561116

Rocker Switch, White (2  in package)

R561117

Rocker Switch, Black (2  in package)

R561119

Rocker Switch, Biscuit (2  in package)

5

R627518

Nameplate, White

R627519

Nameplate, Almond

R627520

Nameplate, Stainless

R627533

Nameplate, Biscuit

R627579

Nameplate, Black

6

R607657

Lens

7

R602534

Screw, 8-18 x 3/8* (2 in package)

8

R602533

Ground Screw (2 req.)

9

R680504

Wiring Cover (includes hardware)

10

*

Rivet, Pop .125 dia.

11

R169016

Filter Spring Kit

12

R169002

Motor Mounting Screw (3 each part)

13

R99080535

Motor (includes Motor Mounting Kit)

14

R401647

Air Chute Assembly

(includes Key No. 15 & hardware)

15

R401646

Baffle

16

R531075

Fan Blade (Includes hairpin clip)

**

R99420635

Hairpin Clip

17

99010299

Filter Kit, for 30” Hood (2 per bag)

99010300

Filter Kit, for 36” Hood (2 per bag)

99010301

Filter Kit, for 42” Hood (2 per bag)

18

R111630

Lamp Socket Harness

19

R7201621

Light Panel, White, for 30” Hood

R7201651

Light Panel, White, for 36” Hood

R7201671

Light Panel, White, for 42” Hood

R7201622

Light Panel, Almond, for 30” Hood

R7201652

Light Panel, Almond, for 36” Hood

R7201672

Light Panel, Almond, for 42” Hood

R7201624

Light Panel, Black, for 30” Hood

R7201654

Light Panel, Black, for 36” Hood

R7201674

Light Panel, Black, for 42” Hood

R720163

Light Panel, Stainless, for 30” Hood

R720166

Light Panel, Stainless, for 36” Hood

R720168

Light Panel, Stainless, for 42” Hood

R7201625

Light Panel, Biscuit, for 30” Hood

R7201655

Light Panel, Biscuit, for 36” Hood

R7201675

Light Panel, Biscuit, for 42” Hood

20

R169004

Indicator Light (includes 2 wire nuts and lens)

**

R169010

Light Diode Assembly (includes wire nut)

**

R111626

Wire Harness

**

99010308

Non-Ducted Filter Kit, 30” (2 per bag)

**

99010309

Non-Ducted Filter Kit, 36” (2 per bag)

**

99010310

Non-Ducted Filter Kit, 42” (2 per bag)

Order replacement parts by PART NO. - not by KEY NO.
* Standard hardware - may be purchased locally.
** Not illustrated.

1

2

3

5

6

9

10

11

13

14

8

4

16

17

3

18

7

19

3

12

20

7

7

15

Summary of Contents for ALLURE WS1 SERIES

Page 1: ...iate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT ...

Page 2: ...LATE FILTERS 1 Determine whether hood will discharge vertically 3 x 10 or 7 Round horizontally 3 x 10 only or non ducted For vertical or horizontal discharge run ductwork between the hood location and a roof cap or wall cap For best results use a minimum number of transitons and elbows 2 Use diagrams below for proper placement of ductwork and electrical cutout in cabinet or wall For a non ducted i...

Page 3: ...screws Disconnect light assembly wire harness white connector 3 8 SCREWS LIGHT PANEL 2 8 SCREWS The following Steps 6 thru 13 are for DUCTED INSTALLATION ONLY BAFFLE 7 Remove Air Chute held in place with one 1 screw NOTE Be careful not to disconnect any wires 9 Rotate baffle Reinsert baffle into air chute as shown so that baffle tabs fit all the way into slots in air chute An audible click will be...

Page 4: ...KNOCKOUT Remove for 3 x 10 Vertical for 7 Round Discharge SEMI CIRCULAR DUCT KNOCKOUT Remove for 7 Round Discharge 13 7 Round Ducted Discharge Only Re install 7 Round Duct Plate removed in Step 1 under PREPARE THE HOOD section Install a 7 round damper purchase separately Damper flap must open freely in direction of air flow away from range hood 12 3 x 10 Ducted Discharge Only Attach Damper Duct Co...

Page 5: ...n The left position is low speed center position is off and right position is high speed An indicator light shows that the fan is on Light The 3 position rocker switch on the right controls the lights The left position is low light intensity center position is off and right position is high light intensity INSTALL HOOD KEYHOLE 4 MOUNTING SCREW 4 1 Hang hood from 4 Mounting Screws from parts bag Sl...

Page 6: ...f the original purchase date NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 SERVICE PARTS KEY NO PART NO DESCRIPTION 1 R680508 7 Round Duct Plate includes hardware 2 R740013 Damper Duct Connector includes hardware 3 R602017 Screw 8 18 x Hex 2 in package 4 R561115 Rocker Switch Almond 2 in package R561116 Rocker Switch White 2 in package R561117 Rocker Switch Black 2 in package R5...

Page 7: ...DEBIDO A GRASA ACUMULADA EN LAS HORNILLAS PROCURE LO SIGUIENTE 1 AHOGUE LAS LLAMAS con una tapa ajustada o charola de metal después apague la hornilla TENGA CUIDADO A FIN DE EVITAR QUEMADURAS Si las llamas no se apagan de inmediato EVACUE Y AVISE A LOS BOMBEROS 2 NO LEVANTE NUNCA UNA SARTEN QUE ESTE EN LLAMAS Usted se podrá quemar 3 NO UTILICE AGUA incluyendo toallas de cocina mojadas puede result...

Page 8: ...tical conducto de 8 3 cm x 25 4 cm 3 x 10 o conducto redondo de 17 8 cm 7 horizontal sólo conducto de 8 3 cm x 25 4 cm 3 x 10 o si es un sistema sin conductos En el caso de descarga vertical u horizontal tienda los conductos entre el lugar donde va a instalar la campana y la tapa de techo o la tapa de pared Para obtener los mejores resultados utilice el número mínimo de transiciones y codos 2 Util...

Page 9: ...ACIONES CON CONDUCTO PANEL DE ILUMINACIÓN 3 8 TORNILLOS 2 8 TORNILLOS 6 Quite el panel de iluminación fijado con 3 8 tornillos y 2 8 tornillos Desconecte el juego del arnés del alambre conectador blanco 7 Quite el conducto para aire fijado con un 1 tornillo NOTA Tenga cuidado de no desconectar ningún cable 8 Quite el deflector del conducto para aire 9 Gire el deflector Vuelva a insertar el deflect...

Page 10: ...ite en el caso de descargas con conductos redondos de 17 8 cm 7 12 Sólo para descargas con conductos de 8 3 cm x 25 4 cm 3 x 10 Coloque el conectador del regulador de tiro conducto sobre la abertura del agujero ciego Asegúrese de que el pivote del regulador de tiro quede lo más cerca posible del borde superior posterior de la campana Quite la cinta de la aleta del regulador de tiro CONECTOR DEL RE...

Page 11: ...agado y la posición hacia la derecha es la velocidad alta Una luz indicadora se ilumina cuando el ventilador está encendido Luz El interruptor oscilante de 3 posiciones de la derecha con trola las luces La posición de la izquierda es luz de baja intensi dad la posición central es apagado y la posición a la derecha es luz de alta intensidad FILTROS SIN CONDUCTOS INSTALACIÓNDELACAMPANA ORIFICIO TIPO...

Page 12: ...rnés de alambres 99010308 Juego de filtros para sin conductos 76 2 cm 2 por bolsa 99010309 Juego de filtros para sin conductos 91 4 cm 2 por bolsa 99010310 Juegodefiltrosparasinconductos 106 7cm 2porbolsa Pida piezas de repuesto dando como referencia el Nº DE PIEZA no el Nº DE CLAVE Herraje estándar se puede comprar en la ferretería de la localidad No ilustrado 1 2 3 5 6 9 10 11 13 14 8 4 16 17 3 ...

Reviews: