FIGURE 1

ADJUSTABLE
ELBOW

• Do not mount over tub or in shower stall enclosure.
• Not for use in kitchens.

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK, OR

INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer.

B. Before servicing or cleaning unit, switch power off at service panel and lock

service panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.

CAUTION:

For general ventilating use only. Do not use to exhaust hazardous or

explosive materials and vapors.

INSTALLATION INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR

INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by 

qualified person(s) in accordance with all applicable codes 
and standards, including fire-rated construction.

B. Sufficient air is needed for proper combustion and exhausting of gases

through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire Protection
Association (NFPA),and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code authorities.

C. When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must 

be marked as appropriate for the application.

F. NEVER place a switch where it can be reached from 

a tub or shower.

G. Do not use this fan with any solid-state speed control device.

FOR BEST RESULTS

When installing the ventilator in a new construction site, install 

the housing during the rough-in construction  of the house. Blower 
and grille should be installed after finished ceiling is in place.

To install the ventilator in an existing house requires accessible 

area above the proposed installation location (attic or crawl space). 
The housing must be installed to a finished ceiling from above.

LOCATION

The ventilator is intended for installation in bathroom or laundry.

CAUTION: Do not install the unit over a tub or in a shower 

stall enclosure.

ROOF
CAP

WALL
CAP

IN CEILING

TRANSITION
FURNISHED
WITH WALL CAP

3"
ROUND
DUCT

FIGURE 2

ADJUSTABLE
ELBOW

ROOF
CAP

WALL
CAP

IN WALL

TRANSITION
FURNISHED
WITH WALL CAP

3"
ROUND
DUCT

FIGURE 3

STANDARD
WALL
SWITCH

GREEN

GROUND

SCREW

SWITCH
BOX

JUNCTION

BOX

EARTH
GROUND

120vAC, 60Hz 

HOUSE POWER

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

INSTALLATION IN A NEW 
CONSTRUCTION SITE

1. Remove the blower unit from the housing by unplugging it then loosening

the three mounting screws and rotating the unit to free it from the screws.

2. Loosely attach housing to ceiling joists through keyhole slots 

in mounting brackets. Keyhole slots in brackets are provided 
to allow for adjustment to various ceiling thicknesses. Adjust
housing so bottom is flush to proposed finished plaster line,
then securely fasten housing to joists.