READ AND SAVE THESE INSTRUCTIONS

WARNING  

TO  REDUCE  THE  RISK  OF  FIRE,  ELECTRIC  SHOCK,  OR 

INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufac-

turer. If you have questions, contact the manufacturer at 

the address or telephone number listed in the warranty.

2.  Before servicing or  cleaning unit, switch power off at

service panel and lock the service disconnecting means 

to prevent power from being switched on accidentally. 

When the service disconnecting means cannot be locked, 

securely fasten a prominent warning device, such as a 

tag, to the service panel.

3.  Installation work and electrical wiring must be done by 

a qualified person(s) in accordance with all applicable 

codes and standards, including fire-rated construction 

codes and standards.

4.  Sufficient  air  is  needed  for  proper  combustion  and 

exhausting of gases through the flue (chimney) of fuel 

burning equipment to prevent backdrafting. Follow the 

heating equipment manufacturer’s guideline and safety 

standards such as those published by the National Fire 

Protection Association (NFPA), and the American Society 

for Heating, Refrigeration and Air Conditioning Engineers 

(ASHRAE), and the local code authorities.

5.  When cutting or drilling into wall or ceiling, do not dam-

age electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  NEVER place a switch where it can be reached from a 

tub or shower.

8.  This unit must be grounded.
9.  This unit is U.L. listed. Type I.C. inherently protected.

CAUTION  

!

1.  For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

2.  This product is designed for installation in FLAT CEILINGS 

ONLY. Do not mount this product in a wall.

3.  The light fixture assembly must be mounted to the fan 

housing  assembly  included  with  this  product.  Do  not 

mount the light fixture assembly to a wiring outlet box.

4.  To avoid motor bearing damage and noisy and/or unbal-

anced impellers, keep drywall spray, construction dust,

etc. off power unit.

5.  Please  read  specification  label  on  product  for  further 

information and requirements.

TYPICAL INSTALLATIONS

HOUSING MOUNTED

DIRECTLY TO JOIST 

2x6 (or larger) 

Discharge parallel to joists.

HOUSING 

2 x 4 

CEILING 

JOIST or 

TRUSS 

MOUNTING 

TABS 

POWER CABLE 

ADDITIONAL 

FRAMING 

2 x 4 

CEILING 

JOIST or 

TRUSS 

CEILING 

MATERIAL 

GRILLE 

PAN 

GLASS

LIGHT SHADE

HOUSING MOUNTED 

TO 2x4 TRUSS

Requires additional framing

for mounting tabs.

Discharge parallel to joists.

HOUSING MOUNTED 

TO “I” JOIST

Requires additional framing 

for mounting tabs.

Discharge parallel to joists.

Installer: 

Leave this manual with the 

homeowner.
Homeowner: 

Use and Care information on page 4.

*

 Additional framing must be a 2x6 (minimum height), at least 9-inches long.

*

*

SUSPENDED CEILINGS

Housing hung with wires - 

3-point mount.

PLAN THE INSTALLATION

The unit will operate 

most quietly and 

efficiently when 

located where the 

shortest possible 

duct run and 

minimum number 

of elbows will be 

needed.
Use a roof cap or 

wall cap that has a 

built-in damper to 

reduce backdrafts.
Plan to supply the 

unit with proper 

line voltage and 

appropriate power 

cable.

ROOF

CAP 

*

4-IN. ROUND

ELBOW(S) 

*

4-IN.

ROUND

DUCT 

*

WALL CAP 

*

*

 Purchase

   separately

INSULATION

(Can be placed 

around and over 

fan housing.)

FAN

HOUSING

Summary of Contents for 768CHNT

Page 1: ...inherently protected CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in FLAT CEILINGS ONLY Do n...

Page 2: ...and a minimum number of elbows 2 Position mounting brackets against joist so that bottom edge of housing will be flush with finished ceiling Additional positioning feature for 5 8 1 1 1 4 thick ceili...

Page 3: ...ct with fan light housing per UL Underwriters Laboratories standards The slightest backdraft however will close the damper flap preventing air from entering unit or finished space 4 Place housing in o...

Page 4: ...TY Broan NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of origi nal...

Page 5: ...atteindre d une baignoire ou d une douche 8 Cet appareil doit tre reli une mise la terre 9 Cetappareilesthomologu U L TypeI C comporteuneprotection interne ATTENTION 1 Cet appareil ne doit servir qu...

Page 6: ...tionnez les brides de montage contre la solive de sorte que le bas du bo tier affleure la surface finie du plafond Positionnement dans des plafonds de 1 6 cm 5 8 po 2 5 cm 1 po et 3 2 cm 1 1 4 po d pa...

Page 7: ...u plafond Clouez chaque bride la solive travers les trous en forme de serrure Pour assurer un fonctionnement silencieux enfoncez un autre clou dans le trou sup rieur de chaque bride B tisse d j constr...

Page 8: ...ctions recommand es La dur e de toute garantie tacite est limit e la p riode d un an stipul e pour la garantie expresse Certains territoires ou provinces interdisant de limiter la dur e d une garantie...

Page 9: ...ar a tierra 9 Esta unidad est incluida en la lista de U L Tipo I C proteger inherente PRECAUCI N 1 Esta unidad debe usarse solamente para ventilaci n general No la utilice para la descarga de material...

Page 10: ...o terminado Caracter stica adicional para la colocaci n en material de cielo raso de 5 8 1 6 cm 1 2 5 cm y 1 3 2 cm Los orificios que se encuentran en las esquinas de la cubierta est n marcados con va...

Page 11: ...da el conducto hasta el exterior a trav s de una tapa de techo o de pared Revise el regulador de tiro para asegurarse de que abre libremente Coloque cinta en todas las conexiones de los conductos para...

Page 12: ...nstrucciones de instalaci n La duraci n de cualquier garant a impl cita se limita a un per odo de un a o seg n se especifica en la garant a expl cita Algunos estados no permiten limitaci n a la duraci...