08/2022 Rev. 1.1
8
To select the synergic program from the list, enter the side tab where the
programs can be examined.
In synergic programs, by pressing the button and switching to the
section
the thickness of the part to be welded can be adjusted. In this case, the
synergistic program will automatically adjust the current and voltage values.
When the welding is not as desired, current and voltage values can be adjusted
manually. Voltage adjustment can be made by using the Welding Voltage Adjust
Button (Figure 1.1-c).
4.2. S YM BOLS AND M EANINGS
After selecting the synergic program, the following features should be set.
Torch Setting
The torch is set to
2T
. Welding starts when the trigger
is pressed and continues until you release it.
The torch is set to
2T Smart
. Welds while holding the
trigger, stops when released. In addition, if the trigger
is briefly pressed and pulled, it switches between the
saved smart programs.
The torch is set to
4T
. Welding starts when you press
and release the trigger, and stops when you press and
release it again. If the trigger is held down before
stopping the weld, crater fill function works.
The torch is set to
4T Smart
. Welding starts when you
press and release the trigger, and stops when you
press it again. In addition, if the trigger is briefly
pressed and pulled, it switches between the saved
smart programs.
Inductance Setting
Increasing the inductance makes the welding more
wide, lowering it makes it more collective.