
27
EN
4.3.2
SETTINGS MENU
To access the settings menu from the operating menu, select "CONTINUOUS" mode and
then press and hold down the
and
keys together.
Press the
key to scroll through the menu items:
1. DOSES
COUNT;
2. TOTAL
COUNT;
3. START
NUMBER;
4. CONTINUOUS
TIME;
5. GENERAL
TIME;
6. MAINTENANCE;
7. STOP
AND
GO;
8. CHOSE
LANGUAGE.
It is only possible to access the settings menu if the portafilter is not inserted.
4.3.2.1
Doses counter
The first item on the settings menu is "DOSES COUNT"; the display shows the following
screen:
'26(6&2817
'26(;1
Where "X" represents the selected dose out of the 3 available (press the
key to change the
dose), and "N" represents the number of doses poured.
The number of doses poured can be reset by holding down the
flashing key for a few
seconds.
4.3.2.2
Total count
The second item in the settings menu is the "TOTAL COUNT"; the display shows the follow-
ing screen:
727$/&2817
$118/1
Where "N" is the total number of doses poured.
The total number of doses poured can be reset by holding down the flashing
key for a few
seconds.
Summary of Contents for Mythos 1 110
Page 1: ......
Page 19: ...16 IT ...
Page 35: ...32 EN ...
Page 51: ...48 FR ...
Page 67: ...64 DE ...
Page 83: ...80 ES ...
Page 86: ......