3.
Setup of the Rotary Kit Encoder
3.1
Setup with Signal Processing in a D-Sub Connector
This setup consists of the following components:
•
EPIFLEX sensor module glued into a very flat frame
• Scale tape with incremental and index track
•
Connector PCB to connect flex cable with round cable of the connector
• Connector with integrated electronics (1 V
PP
or RS 422) and cable
3.2
Setup with Signal Processing on a Connector PCB
This setup consists of the following components:
•
EPIFLEX sensor module glued into a very flat frame
• Scale tape with incremental and index track
• Connector PCB with integrated electronics (1 V
PP
or RS 422)
• Connector with cable
Image 1
000
000
0
00
000
000
000
00
0
(+)
Connector
PCB
Flex cable
JST-Connector
15 pin D-Sub
connector with
electronics
EPIFLEX sensor
module with Frame
Scale tape
Round cable
Diagnostic socket for
ADJUSTMENT TOOL
Image 2
000
000
0
00
000
000
000
00
0
(+)
Connector
PCB with
electronics
Flex cable
JST-Connector
Connector
Round cable
Diagnostic socket for
ADJUSTMENT TOOL
Scale tape
EPIFLEX sensor
module with Frame
9/58
KIT