Num'axes Canicom 500 Pro User Manual Download Page 1

User’s guide CANICOM 500 PRO – indice B

1/12

User’s guide

DECLARATION « CE » DE CONFORMITE / « EC » DECLARATION OF CONFORMITY

Directive R&TTE 1999/5/CE

NUM’AXES

déclare que / declares that

le collier d’éducation / the training collar

CANICOM 500 PRO

satisfait à toutes les dispositions de la Directive R&TTE N° 1999/5/CE du 07/04/99 du Conseil Européen

complies to all dispositions of the European Council R&TTE Directives below N° 1999/5/CE

et est conforme aux normes suivantes / and complies with standards below:

ETSI EN 300 220 / EN 301 489-3 V1.4.1

NUM’AXES

Z.A.C. des Aulnaies - 745 rue de la Bergeresse – BP 30157

45161 OLIVET CEDEX – FRANCE

Tél. + 33 (0)2 38 63 64 40 / Fax + 33 (0)2 38 63 31 00

01/05/2008 - Pascal GOUACHE -Président du Directoire

WARNING

Any person with individual device for cardiac assistance (pacemaker, defibrillator) must take

precautions when they use CANICOM 500 PRO.

This device emits some static magnetic fields (a magnet is located in the remote control).

Frequency= 869 MHz, at = 250 mW

The device complies with the European Standards ETSI EN 300 220 and EN 301 489-3 V1.4.1.

Thank you for choosing a NUM’AXES product.

Before using your CANICOM 500 PRO, please read the instructions in this guide carefully and keep it for future

reference.

Before using the collar, we advise you to have your dog checked by your vet to ensure he is fit to wear

a collar.

Regularly check your dog’s neck as repeated rubbing of the contact points against the animal’s skin

may cause irritation. If this happens, remove the collar until all signs of skin irritation have

disappeared. Do not leave the collar more than 8 hours per day on your dog.

Start with the lowest level of stimulation and define the level from which your dog reacts by

increasing gradually.

Do not hesitate to contact a professional trainer for any further advice.

Summary of Contents for Canicom 500 Pro

Page 1: ...llator must take precautions when they use CANICOM 500 PRO This device emits some static magnetic fields a magnet is located in the remote control Frequency 869 MHz at 250 mW The device complies with...

Page 2: ...lar equipped with short contact points 3 V Lithium CR2 battery for the collar CANICOM 500 PRO remote control equipped with a 3 V Lithium CR2 battery screwdriver neon test lamp pair of long contact poi...

Page 3: ...life of the remote control and receiver collar you should deactivate the units if you are not using them for a long period Activate deactivate the CANICOM training collar A magnet located in the remot...

Page 4: ...the coding first use of receiver collar or re coding make sure no other person is using his CANICOM 500 PRO or other products from the NUM AXES range close by your receiver collar could accidentally...

Page 5: ...r by testing the operation of the CANIBEEP RADIO PRO 7 Once you have finished the coding put the top back in place paying attention to the rubber seal It must be clean well positioned in its groove an...

Page 6: ...the remote control The indicator light on the collar goes from flashing green to permanent red while the stimulations are being sent If you press the C button for more than 8 seconds the collar will...

Page 7: ...lar operation settings cautions for use technical specifications please read the user s guide provided with the collar Checking replacing battery of remote control Performance radio range of the remot...

Page 8: ...receiver collar Press the F or C button and modify the level of intensity of the stimulations the test lamp will come on with more or less intensity Getting the best results The training instructions...

Page 9: ...ildren with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person respo...

Page 10: ...r product for service and repair For all repairs please supply the following the complete product the proof or purchase invoice or sales receipt If you omit one of these items the After Sales Service...

Page 11: ...uctions or not envisioned therein repairs performed by unauthorized persons loss or theft 3 If the product is found to be defective NUM AXES will either decide to repair or to replace it 4 No claim ma...

Page 12: ...s guide CANICOM 500 PRO indice B 12 12 NUM AXES ZAC des Aulnaies 745 rue de la Bergeresse BP 30157 45161 OLIVET CEDEX FRANCE Tel 33 0 2 38 63 64 40 Fax 33 0 2 38 63 31 00 www numaxes com export numaxe...

Reviews: