background image

If exposed to any of the Chemicals mentioned in the Hazards section please follow the procedures 

below:

Eyes.

Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelid. 

Seek medical attention.

Skin.

Remove contaminated clothing and rinse skin with plenty of water or shower for 15 minutes.

Seek medical attention.

Inhalation.

Vacate from site of exposure to fresh air immediately. Use oxygen if available.

Ingestion.

Give at least two glasses of milk or water. Induce vomiting unless patient is unconscious. 

Seek medical attention. 

Note: 

Inhalation, skin contact and eye contact are possible if the battery is damaged. 

Exposure to internal contents, the corrosive fumes will be very irritating to skin, eyes and mucous 

membranes.

Overexposure can cause symptoms of non-fibroid lung injury and membrane irritation.

First Aid Measures

Data

Spare Parts

902928

Lithium-Ion Battery

903245

Charger UK (Hard Wired)

901607

11” TriTex Filter

909291

NVM - 1CH HepaFlo Dust bags x 3

907076

NVM - 1CH HepaFlo Dust bags x 5

907075

NVM - 1CH HepaFlo Dust bags x 10

Drum Size

Operating Times

Weight

(Ready to work)

Protection 

Class

1 Battery

7.2 L

Hi = >20 mins Lo = >30 mins

6.88 kg

Class III

2 Battery

Hi = >40 mins Lo = >60 mins

Sound Pressure (LpA)

Uncertainty (KpA)

Size

LpA ≤ 70dB (A)

0.5 dB

360 mm x 370 mm x 390 mm

Summary of Contents for AS29E

Page 1: ...ginal Instructions Original Instructions CAUTION Read instructions before using the machine CAUTION Read instructions before using the machine www numatic com NVB170 12 Lithium Ion Battery Powered Kit...

Page 2: ...Kit AS29E Assembly...

Page 3: ...ator show battery state of charge S0C Recharging required Indicator does not illuminate Error Condition Indicator flashes on off Using your machine Operating your machine for the first time Your Batte...

Page 4: ...Using your machine Wand docking Tool Tidy Low Low...

Page 5: ...Cleaning 9 1 2 3 4 1 2...

Page 6: ...Fitting the Face Removing the Face...

Page 7: ...erations M A I N T E N A N C E NOTE A risk assessment should be conducted to determine which PPE should be worn WEEE Legislation Waste Electrical and Electronic Equipment Vacuum cleaner accessories an...

Page 8: ...ttery Technical Helpline 1 703 741 5970 If the vacuum cleaner has a blockage switch off remove the battery from the appliance and inspect the floor tool wands and hose for debris If the floor tool wan...

Page 9: ...al advice immediately if a cell or battery has been swallowed k Use only original NUMATIC batteries when replacement batteries are required l Keep cells and batteries clean and dry m Secondary cells a...

Page 10: ...ppropriate battery condition checking device operated by a competent person If on checking the battery is found to be operational then a single recharge cycle under observation can be attempted with t...

Page 11: ...NDICATOR STATUS Green Continuously On Charge Complete Green Flashing Without Pause Charger in Standby Red Continuously On Charging Red Flashing Without Pause Preparing to Charge ERROR INDICATOR STATUS...

Page 12: ...an alternative non Numatic charger be used as there is risk severe damage and fire could result Only use genuine Numatic parts The charger is intended for use only on flat surfaces place horizontally...

Page 13: ...al attention Note Inhalation skin contact and eye contact are possible if the battery is damaged Exposure to internal contents the corrosive fumes will be very irritating to skin eyes and mucous membr...

Page 14: ......

Page 15: ...ional will guarantee your Numatic Lithium Ion battery for 500 recharging cycles providing the cycles have been car ried out to the manufacturer s specifications and requirements Failure to use the cor...

Page 16: ...ject to change without prior notice www numatic co uk Numatic International Limited Distributed by UNITED KINGDOM www numatic co uk GERMANY www numatic de SWITZERLAND www numatic ch FRANCE www numatic...

Reviews: