
heart rate limits etc.
F P3: Freely Programmable Target Zone & Exercise Time
The original stored target zone and the exercise time
25
minutes of
F P3
mode are the same as
F P1
. In
F P3
mode you can freely set high/low target zone limits and exercise time by changing the flashing digits.
Press the S KEY or hold the S KEY down (same method as Age Input) to increase numbers of the first digit
of the high limit. Press the M KEY to confirm and then shift to 2
nd
digit. All other digits for high/low limits
and exercise time can be adjusted by the same method. Once these are set enter
F P4
of the
Average Heart
Rate
calculation period selection mode.
NOTE
1. Low/High Limit of Target Zone range: 35-250 BPM
2. Low Limit must not be higher than High Limit
3. Exercise time range: 0-9:59:59 (H/M/S)
F P4: Selection of Average Heart Rate Calculation Period
6 optional calculation periods of 10, 20, 30, 40, 50 and 60 minutes are provided for average heart rate
calculation and display. Press S KEY to select the period you want, and then press the M KEY to
CLOCK
MODE.
Please refer to the flow chart of operation.
Model: HM8033
www.nu-beca.com