Guidance and manufacturer’s declaration – electromagnetic 

immunity 

The FT7122 is intended for use in the electromagnetic environment specified below. The customer or the user of 

the FT7122 should assure that it is used in such an environment.

 

Immunity 
test 

IEC 60601 test 

level

 

Compliance 

level

 

Electromagnetic environment 

– 

guidance

 

 

 

 

 

 

 

 

 

 

Radiated RF 

IEC 61000-4-3

 

 

 

 

 

 

 

 

 

 

 

3 V/m 

80 MHz to 2,5 GHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3  V/m

 

 

Portable and mobile RF communications 

equipment should be used no closer to any 

part of the FT7122 including cables, than 

the recommended separation distance 

calculated from the equation applicable to 

the frequency of the transmitter.

 

 

Recommended separation distance

 

                                                                                                                                                                                           

d = 

1,2 

 

 

                                                                                                                                                                           

d = 

1,2 

 

80 MHz to 800 MHz

 

                                                                                                                                                                                   

d = 

2,3 

 

800 MHz to 2,5 GHz

 

 

where 

is the maximum output power 

rating of the transmitter in watts (W) 

according to the transmitter manufacturer 

and 

is the recommended separation 

distance in metres (m).

 

 

Field strengths from fixed RF transmitters, 

as determined by an electromagnetic site 

survey,

should be less than the compliance 

level in each frequency range.

b

 

 

Interference may occur in the vicinity of 

equipment marked with the following 

symbol:

 

Summary of Contents for FT7122

Page 1: ...13 Applying Standards 7 Section 14 Symbol Explanation 7 Section 14 EMC Table 8 Read the instruction manual thoroughly and carefully before using the unit What is normal body temperature Normal body t...

Page 2: ...ce is not intended to be a substitute for consultation with your physician 3 Disregarding the information given in this instruction manual is considered to be abnormal use 4 The device is for indoor u...

Page 3: ...article IP 22 The thermometer is not waterproof Note 1 The thermometer is an adjusted mode clinical thermometer Note 2 This thermometer converts the forehead temperature to display its oral equivalent...

Page 4: ...d it against the measurement location to ensure good contact with the skin is maintained Correct placing and good contact with the skin ensure reliable readouts Make sure the thermometer and the patie...

Page 5: ...Drawings Instructions 1 Gently press the top of the battery cover so as to release the battery cover 2 Slide back the battery cover 3 Take the battery out When placing a new battery please make sure t...

Page 6: ...is included in the LOT The LOT has 5 numbers The first number means the year 0 9 The second number means the month Jan Sep 1 9 Oct A Nov B Dec C The third and fourth numbers mean the date 1 31 And the...

Page 7: ...ANDARDS 1 MDD 93 42 EEC 2 EN 60601 1 2006 AC 2010 3 EN 60601 1 2 2007 4 EN ISO 80601 2 56 2012 5 ASTM E1112 00 Symbol Explanation The CE mark and Notified Body Registration Numbers the requirement of...

Page 8: ...hat supplies buildings used for domestic purposes Harmonic emissions IEC 61000 3 2 Not applicable Voltage fluctuations flicker emissions IEC 61000 3 3 Not applicable Guidance and manufacturer s declar...

Page 9: ...ations equipment should be used no closer to any part of the FT7122 including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitte...

Page 10: ...broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered I...

Page 11: ...o 800 MHz d 1 2 800 MHz to 2 5 GHz d 2 3 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommen...

Reviews: