SQF

Installation Manual

S1 duty and Emergency in S2 duty: 
a) Permanently greased bearings. 

400°C range; replace on 2 pole motors after 10,000 hours of operation 
and on motors with 4 poles or more after 20,000 hours.

b) Re-greaseable bearings 

The information on the motor nameplates must be strictly respected 
(grease quantity, grease quality and re-greasing frequency).  
The bearings must be replaced after 20,000 hours of operation.

6.0 MAINTENANCE

IMPORTANT

Isolation - Before commencing work make sure that the unit and 

Nuaire control are electrically isolated from the mains supply.

Ensure that all mechanical and electrical connections and fixings are 
secure and that inlet and outlet ductwork is free of any obstruction or 
debris.

Briefly switch the fan on/off to ascertain correct direction of impeller 
rotation, compare with the rotational label fitted and correct if 
necessary.

Complete the test by running the fan for approximately 15 minutes, 
taking and comparing voltage, full load and starting currents with the 
fan rating label. Monitor flexible connections to ensure no leakage and 
AV mounts for correct alignment.

It is important that maintenance checks are recorded and that the 
schedule is always adhered to, in all cases, the previous report should 
be referred to.

6.1 Routine Maintenance

Clean all areas of unit and treat any areas of corrosion.

Check all access doors for leakage and if necessary locks should be 
adjusted and any replacement gasket materials should be replaced 
as required. 

Check that safety grilles are secure and free of obstruction.

6.2 Semi-Annually 

Thoroughly inspect the unit and its components for corrosion, 
acting immediately to treat/restore any damaged areas. 

All electrical terminals within the unit should be tightened. 

Check all earth connections. 

Check resilient mounts (where applicable) and replace any that 
have any wear or deterioration.

Check motor for undue wear, signs of overheating and apply 
winding insulation and continuity tests.

6.3 Lubrication

Motors are fitted with sealed for life bearings and do not require any 
lubrication.

6.4 Motor Repair

Due to unit certification EN12101-3 and in compliance with the 
construction products directive, the motor must be returned to the  
motor manufacturer for replacement.

7.0 WARRANTY

The 3 year warranty starts from the day of delivery and includes parts 
and labour for the first year. The labour element is subject to full, 
free and safe access to the equipment as recommended by the CDM 
regulations. The remaining two years covers replacement parts only.

This warranty is void if the equipment is modified without 
authorisation, is incorrectly applied, misused, disassembled, or not 
installed, commissioned and maintained in accordance with the details 
contained in this manual and general good practice.

The product warranty applies to the UK mainland and in accordance 
with Clause 14 of our Conditions of Sale. Customers purchasing from 
outside of the UK should contact Nuaire International Sales office for 
further details.

Failure to maintain the unit as recommended will invalidate the 
warranty.

8.0 END-OF-LIFE  AND RECYCLING

Where possible Nuaire use components which can be largely recycled 
when the product reaches its end-of-life:

Fans, motors, controls, actuators, cabling and other electrical 
components can be segregated into WEEE recycling streams.

Sheet metal parts, aluminium extrusion, heating/cooling coils and 
other metallic items can be segregated and fully recycled.

Cardboard packaging, wood, used filters and other paper 
components can be largely recycled or fully processed in energy 
from waste centres.

Remaining items can be further segregated for energy from waste 
centres or, as a last resort, sent to landfill. Please call After Sales 
Support for further information on items not listed above.

IMPORTANT

Ensure that Nuaire product is made safe from any electrical 

/ water / refrigerant supplies before dismantling commences. 

This work should only be undertaken by a qualified person in 

accordance with local authority regulations and guidelines, 

taking into account all site based risks.

9.0 AFTER SALES AND REPLACEMENT PARTS

For technical assistance or further product information, including spare 
parts and replacement components, please contact the After Sales 
Department.

If ordering spares please quote the serial number of the unit together 
with the part number, if the part number is not known please give a full 
description of the part required. The serial number will be found on the 
identification plate attached to the unit casing.

Telephone 02920 858 400 

[email protected]

Technical or commercial considerations may, from time to time, make it necessary to alter the design, performance and dimensions of equipment 

and the right is reserved to make such changes without prior notice.

Summary of Contents for Square Single In-line Fan Series

Page 1: ...ving any covers During installation maintenance ensure all covers are fitted before switching on the mains supply All pole disconnection from the mains as shown in the wiring diagram must be incorpora...

Page 2: ...equipment is inspected prior to despatch and leaves the factory in good condition Upon receipt of the equipment an inspection should be made and any damage indicated on the delivery note Particulars o...

Page 3: ...off to maximise isolation and the flexible connectors correctly aligned with the fan at the correct tension IMPORTANT A V mounts isolate the fan only Silencers backdraught dampers and other significan...

Page 4: ...the home they are therefore subject to strict constraints concerning their operating and maintenance Operating Constraints i Check on the nameplate that the selected unit corresponds to the maximum e...

Page 5: ...replacement 7 0 WARRANTY The 3 year warranty starts from the day of delivery and includes parts and labour for the first year The labour element is subject to full free and safe access to the equipmen...

Page 6: ...04 02 20 Document Number 671834 6 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk SQF Installation Manual NOTES...

Page 7: ...04 02 20 Document Number 671834 7 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk SQF Installation Manual NOTES 7...

Page 8: ...ortant that the specified operational limits for the equipment are adhered to e g operational air temperature air borne contaminants and unit orientation 4 2 Where installation accessories are supplie...

Reviews: