Installation Manual

1.2 Important Information

This manual contains important information on the safe and 
appropriate assembly, transport, commissioning, operation, 
maintenance, disassembly and simple troubleshooting of the product.

While the product has been manufactured according to the accepted 
rules of current technology, there is still a danger of personal injury or 
damage to equipment if the following general safety instructions and 
the warnings contained in these instructions are not complied with.

Read these instructions completely and thoroughly before 
working with the product.

Keep these instructions in a location where they are accessible 
to all users at all times.

Always include the operating instructions when you pass the 
product on to third parties.

1.3 Personal Protective Equipment

The following minimum Personal Protective Equipment (PPE) is 
recommended when interacting with Nuaire product:

Protective Steel Toed Shoes - 

when handling heavy objects.

 

Full Finger Gloves (Marigold PU800 or equivalent) - 

when 

handling sheet metal components. 

Semi Fingerless Gloves (Marigold PU3000 3DO or equivalent) 

- when conducting light work on the unit requiring tactile 
dexterity. 

Safety Glasses

 - when conducting any cleaning/cutting operation 

or exchanging filters. 

Reusable Half Mask Respirators 

- when replacing filters which 

have been in contact with normal room or environmental air.

Nuaire would always recommend a site specific risk assessment by a 
competent person to determine if any additional PPE is required. 

2.0 INTRODUCTION

The SQF range of fans are designed for in-duct applications. 
Manufactured from galvanised steel, they are suitable for in or outdoor 
installation and can be installed in a horizontal or vertical attitude.

For full unit description, dimensional, weight and performance details 
refer to Nuaire catalogue.

The units are designed for: 

S1 DUTY - Day to day operation and in the 

event of fire a one off emergency use.

2.1 Code Description:

SQF 4 5  T

  |      |  |   |

  1     2 3  4    

1. Range:   

 

Square Single In-line Fan

2. Motor Poles:  

 

4 or 6

3. Size:   

 

1, 2, 3, 4, 5 or 6 (4 Pole Motors Only) 

 

 

 

1, 2, 3 or 4 (6 Pole Motors Only)

4. Control Type: 

 

No Suffix

 = Speed Controllable 

   

= Two Speed Motor Control

3.0 DELIVERY & HANDLING

All equipment is inspected prior to despatch and leaves the factory in 
good condition. Upon receipt of the equipment an inspection should 
be made and any damage indicated on the delivery note. Particulars of 
damage and/or incomplete delivery should be endorsed by the driver 
delivering the goods before offloading by the purchaser. 

No responsibility will be accepted for damage sustained during the 
offloading from the vehicle or on the site thereafter. All claims for 
damage and/or incomplete delivery must be reported to Nuaire within 
two days of receipt of the equipment.

Always handle the units carefully to avoid damage and distortion. If 
mechanical aids are used to lift the unit, spreaders should be employed 
and positioned so as to prevent the slings, webbing etc. making contact 
with the casing. 

Note the weight from the rating plate, lift using slings attached to the 
four lifting eyes as (figure 1).

Care must be taken when handling a unit/attenuator assembly 
fitted with flexible connectors as the connectors can be distorted or 
damaged.

IMPORTANT

Please ensure that there is adequate clearance for the removal 

of the motor/fan assembly for maintenance purposes.

4.1 Mechanical Installation

Fans are suitable for both internal and external installation and whilst 
they can be installed in either the recommended vertical (installation 
type A) or alternative horizontal (installation type B) attitude, the 
standard brackets provided are suitable only for the more conventional 
vertical (A) mounting position.

Where silencers are to be fitted to the unit (for all sizes except 
SQF41), installation type A should be used to ensure silencer 
splitters are vertically orientated (Figure 2). SQF41 silencers are 
square and can be rotated to ensure vertical orientation in either 
installation type.

4.0 INSTALLATION

Installation must be completed by competent persons, in accordance 
with good industry practice and should conform to all governing and 
statutory bodies regulations i.e. IEE, CIBSE, etc. and EN standards etc.

Before commencing installation check that all material, including 
mounting feet and optional ancillaries are available to complete the 
work. Every unit is tested and serialised at works and a test certificate 
produced, the details are also recorded on the fan side rating plate 
which should also be referred to before handling and installation. Any 
damage or deviations should be immediately reported to the seller/
supplier/agent quoting the order and rating plate details.

Lifting Unit Via Lifting Eyes

Summary of Contents for Square Single In-line Fan Series

Page 1: ...ving any covers During installation maintenance ensure all covers are fitted before switching on the mains supply All pole disconnection from the mains as shown in the wiring diagram must be incorpora...

Page 2: ...equipment is inspected prior to despatch and leaves the factory in good condition Upon receipt of the equipment an inspection should be made and any damage indicated on the delivery note Particulars o...

Page 3: ...off to maximise isolation and the flexible connectors correctly aligned with the fan at the correct tension IMPORTANT A V mounts isolate the fan only Silencers backdraught dampers and other significan...

Page 4: ...the home they are therefore subject to strict constraints concerning their operating and maintenance Operating Constraints i Check on the nameplate that the selected unit corresponds to the maximum e...

Page 5: ...replacement 7 0 WARRANTY The 3 year warranty starts from the day of delivery and includes parts and labour for the first year The labour element is subject to full free and safe access to the equipmen...

Page 6: ...04 02 20 Document Number 671834 6 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk SQF Installation Manual NOTES...

Page 7: ...04 02 20 Document Number 671834 7 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk SQF Installation Manual NOTES 7...

Page 8: ...ortant that the specified operational limits for the equipment are adhered to e g operational air temperature air borne contaminants and unit orientation 4 2 Where installation accessories are supplie...

Reviews: