Installation and Maintenance    

QUIETWIN  QTR BELT DRIVE TWINFAN

3

General

Electrical                        Weight

1 Phase (230v)         3 Phase (400V)

kg   

(nominal)

Unit

Speed

Power

f lc

sc

Code

*

rpm

(kw)

(amps)

(amps)

QTR*A 1-3*

535

0.18

0.75

2.3

73

QTR*A 2-3*

705

0.18

0.75

2.3

73

QTR*A 3-1*

835

0.25

2.1

5.3

75.4

QTR*A 3-3*

835

0.25

0.95

3.0

75.4

QTR*A 4-1*

835

0.37

2.9

7.3

77.5

QTR*A 4-3*

835

0.37

1.3

4.6

77.5

QTR*A 5-1*

935

0.25

2.1

5.3

75.4

QTR*A 5-3* 

935

0.25

0.95

3.0

75.4

QTR*A 6-1*

935

0.37

2.9

7.3

77.5

QTR*A 6-3*

935

0.37

1.3

4.6

77.5

QTR*A 7-1*

1045

0.25

2.1

5.3

75.4

QTR*A 7-3*

1045

0.25

0.95

3.0

75.4

QTR*A 8-1*

1045

0.37

2.9

7.3 

77.5

QTR*A 8-3*

1045

0.37

1.3

4.6

77.5

QTR*A 9-1*

1045

0.55

3.4

9.3

84.4

QTR*A 9-3*

1045

0.55

1.7

6.8

84.4

QTR*A 10-1*                1125

0.37

2.9

7.3

77.5

QTR*A 10-3*

1125

0.37

1.3

4.6

77.5

QTR*A 11-1*

1125

0.55

3.4

9.3

82.4

QTR*A 11-3*

1125

0.55

1.7

6.8

82.4

QTR*A 12-3*

1125

0.75

2.1

9.5

84.4

QTR*A 13-1*

1225

0.37

2.9

7.3

77.5

QTR*A 13-3*

1225

0.37

1.3

4.6

77.5

QTR*A 14-1*

1225

0.55

3.4

9.3

82.4

QTR*A 14-3*

1225

0.55

1.7

6.8

82.4

QTR*A 15-3* 

1225

0.75

2.1

9.5

84.4

QTR*A 16-3*

1225

1.1

2.9

13.0

90.4

QTR*A 17-1*

1335

0.55

3.4

9.3

82.4

QTR*A 17-3*

1335

0.55

1.7

6.8

82.4

QTR*A 18-3*

1335

0.75

2.1

9.5

84.4

QTR*A 19-3*

1335

1.1

2.9

13.0

90.4

QTR*A 20-1*

1400

0.55

3.4

9.3

82.4

QTR*A 20-3*

1400

0.55

1.7

6.8

82.4

QTR*A 21-3*

1400

0.75

2.1

9.5

84.4

QTR*A 22-3*

1400

1.1

2.9

13.0

90.4

QTR*A 23-3*

1400

1.5

3.7

18.5

96.4

CASE SIZE ‘A’

Table  4.   Start & Run currents etc.

Electrical Details

(See table 3, 4 & 5).

Because the run and start currents depend upon the duty and asso-
ciated ductwork of an individual unit, the values quoted in the
table are nominal.
Run currents will be exceeded if the unit is operated with its cover
removed. It is therefore recommended that the unit is not run for
prolonged periods in this condition.

QTRB D  BOTTOM / END  INLET 
Size:  D  only.

Rect Spigot 

Unit

A

B

C

E              F

QTRR D

2315

2500

1230

1200

700

QTRB D

2315

2500

1230

1200

700

Table 3.  

DIMENSIONS (mm)

For unit weights 
see  table 7

Louvred
end outlet

Bottom rectangular inlet spigot
Code: QTRB

F

E

B

A

C

F

E

End inlet rectangular spigot
Code: QTRR

Fig. 4. 

Testing after Installation

Ensure that the Fan unit and Control and particular control 
ancillaries  if specified  eg  PIR, Run/Fail indicators, timeclock etc.
are fitted.

Switch on and check that the fan unit runs satisfactorily. 

Using your chosen control, switch over to the standby fan by
means of the control's fan selection switch.

Check that the change-over occurs. 

Switch off. If a Run-on Timer  is fitted, check that the fan contin-
ues to run. 

Time the run-on period, which is adjustable between 5 and 60
minutes nominal. 

Timer controls are set at the works to the shortest period. 

For speed controls follow the installation set-up procedure 
provided with the control.

QTE*B1-3* =  Quietwin, duct mounted, external use, 

case size B, performance curve 1, 
3 phase electrical supply

Control choice ‘M’ or ‘C’

Spigot location choice (see page 1)

** CODING eg.

Summary of Contents for QUIETWIN QTR

Page 1: ...ames are supported on the base by resilient mountings allowing the fan unit to be operated with out the need for separate anti vibration fan case mountings The units incorporate two independent motors...

Page 2: ...he installer the lower edge of the casing has an internal skirt allowing the unit to be located on an upstand or prefabricated curb if desired See prefabricated curb details on page 5 The unit should...

Page 3: ...23 3 1400 1 5 3 7 18 5 96 4 CASE SIZE A Table 4 Start Run currents etc Electrical Details See table 3 4 5 Because the run and start currents depend upon the duty and asso ciated ductwork of an individ...

Page 4: ...t Drive Twinfans continued Table 5 Start Run currents etc CASE SIZE B Table 6 Start Run currents etc CASE SIZE C Installation and Maintenance QUIETWIN QTR BELT DRIVE TWINFAN 4 General Electrical Weigh...

Page 5: ...nit Support Base Removable top covers Unit support base Inlet spigot 2500 2315 200 1200 1200 200 min100 min 75 50 1790 2490 Unit Weight and Fixing Size D units For unit weights see electrical informat...

Page 6: ...power control Figure 9b 6 3 YEAR WARRANTY The three year warranty starts from the date of delivery and includes parts and labour for the first year The labour element is subject to full free and safe...

Page 7: ...the User Control is included inside the fan unit for delivery to site Take care not to misplace the item before installation Wiring Connections Supply 230V 1 Phase to terminals E N L in control module...

Page 8: ...K Y RUN FAULT Low voltage Communications Cable Not used in this option MT AVI connection BL RD BK Y MICROSAVE USER CONTROL CONTROL MODULE IN FAN Single phase QUIETWIN with MICROSAVE control Link Link...

Page 9: ...S Building Management System override control on off and system status Code Description CT A Auto duty sharing CT M Manual duty sharing Mains Control Options NOTE See relevant Installation Maintenance...

Page 10: ...1 L2 N E H BL RD BK Y RUN FAULT 230v MAINS CONTROL 230v 1 phase supply Link Link NET CT AVI Audible Visual Indicator connection QUIETWIN FAN Three phase 230v Switched Live Connection twinfan operates...

Page 11: ...es operate freely by locating the spindle and flap through the blower outlet aperture and carefully moving the flap A click will be heard when the switch operates See fig 11 NOTE Do not bend the flaps...

Page 12: ...g switches operate freely by locating the spindle and flap through the blower outlet aperture and carefully moving the flap A click will be heard when the switch oper ates See fig 14 NOTE Do not bend...

Page 13: ...30364 530373 530368 530372 530367 530373 530368 530372 530367 530373 530368 530374 530369 530373 530368 530374 530369 530375 530373 530368 530374 530375 530376 530374 530369 530375 530376 530374 53036...

Page 14: ...e Directive Applied Harmonised Standards E50081 1 EN50082 1 EN60204 1 EN60335 2 80 Basis of Self Attestation Quality Assurance to BS EN ISO 9001 BSI Registered Firm Certificate No FM 149 Signature of...

Page 15: ...37 EC Machinery Directive 93 44 EEC Amendment to the Machinery Directive Applied Harmonised Standards EN292 1 EN292 2 EN294 EN29001 Applied National Standards BS848 Parts One Two and Five Signature o...

Page 16: ...tion 4 2 Where installation accessories are supplied with the specified equipment eg wall mounting brackets They are to be used to support the equipment only Other system components must have separate...

Reviews: