Installation and Maintenance

NTD - Nuaire Thermal Ducting

19. 08. 19. Leaflet Number 671780

 

Flat Ductmaster 

Fire Wrap

Flat rigid PVC
within flat Ductmaster
Thermal Ducting

Typical internal
partition wall 

Internal flat duct connector
min 100mm either side of
fire damper

Ducting to butt up
against fire collar

 Flat Ductmaster 

Thermal duct

Thermal duct

Rigid PVC
duct connector

Rigid PVC
duct connector

Condensation trap

Flat Ductmaster
ducting 

Typical
cavity
wall 

Single 
airbrick

PVC
 flat
duct 

Flat duct
connector

Thermal
duct 90° bend

 

Rigid PVC
duct
connector

Rigid PVC
duct
connector

 

Standard
flexible
ducting

Standard
flexible
ducting

Air valve

Air valve

Thermal
duct
plenum

 

2.3 Flexible Duct Connections Between Air Valves and  
Plenums/Bends

2.5 Condensate Trap In Thermal Ducting

2.4 Air Brick Connection Detail

2.6 Fire Wrap in Rectangular Thermal Ducting

2.7 Attenuator in Thermal Ducting

3.0 CUTTING DUCTING

A flush, square 90° cut is required to ensure that an air tight seal is 
made with centre ridge in the clamp. If an angled cut is made, this 
will not allow the duct clamps to create a seal on the duct. We advise 
that the duct is cut with a very sharp blade or fine toothed saw (we 
recommend a minimum of 14 teeth per inch). The cutting blade length 
should be at least the same length as the wall thickness of the ducting.  
 

Ensure duct is placed into duct clamp connector prior to 
installation to check the squareness of the cut ducting.

Nuaire Thermal Ducting is supplied in 1 metre lengths.  

If shorter lengths are required the duct can be cut to the 

desired length with a fine toothed saw (minimum of 14 teeth 

per inch). Failure to make a square cut may result in airflow 

leakage when connecting to other ducting pieces. Ensure duct 

is placed into the duct clamp connector prior to installation to 

check the squareness of the cut ducting (see fig. 9a and 9b). 

IMPORTANT

Figure 4. Typical 

flexible ducting 

between air valve and 

plenum/bend.

Figure 5. Typical 

rectangular thermal 

duct with an air 

brick.

Figure 6. Condensate 

trap with rigid PVC 

duct connectors.

Figure 7. Typical 

rectangular thermal 

duct with fire wrap.

Figure 9a. A square 90° cut is required to ensure an airtight seal. 

NTD-204-CUTTINGAID for 204 
x 60mm rectangular duct.

NTD-125-CUTTINGAID for 

125mm Ø circular duct.

Figure 9b. Non-square cut resulting in air leakage from duct.

Figure 10. Cutting aids are available from Nuaire.

Flat Ductmaster 

Attenuator to be placed inside of 1M

length of Nuaire flat thermal duct 

Internal duct

flat connector

Note: Internal black connectors to be removed

 from thermal ducting prior to inserting attenuator. 

Internal duct

flat connector

Figure 8. Typical 

rectangular 

thermal duct with 

an attenuator.

Square cut edge of duct 
length must meet centre
ridge of clamp to ensure
airtight seal.

If an angled cut is made on
the duct then this will not
allow the clamps to make
an airtight seal

Summary of Contents for NTD-125 Series

Page 1: ...angular duct 2 0 INSTALLATION Installation must be carried out by competent personnel in accordance with the appropriate authority and conforming to all statutory governing regulations The ducting mus...

Page 2: ...ucting Ensure duct is placed into duct clamp connector prior to installation to check the squareness of the cut ducting Nuaire Thermal Ducting is supplied in 1 metre lengths If shorter lengths are req...

Page 3: ...ck in place 5 0 FITTING DUCT BANDING For installation onto a solid surface suitable duct banding must be used to support both the rectangular and circular ducting and should be fitted every 1m When fi...

Page 4: ...art no PVC505NS Intake air from outside via air brick Part no PVC505NS Insulated rectangular pipe 204 x 60mm Part no NTD 204 1M Insulated 90o horizontal bend 204 x 60mm Part no NTD 204 90H Duct suppor...

Page 5: ...rther details Our Technical Support department will be happy to provide any assistance required initially by telephone and if necessary will arrange for an engineer to call Telephone 029 2085 8400 tec...

Page 6: ...end NTD 125 45H 125mm Insulated 45 Bend NTD 125 1M 125mm Insulated Duct 1m Length NTD 125 INS 125mm Inner Duct Connector NTD 125 OPC 125mm One Piece Connector Duct Clamp Part Number Duct Size Descript...

Page 7: ...nd NTD 204 90V 204mm x 60mm Insulated 90 Vertical Bend NTD 204 45V 204mm x 60mm Insulated 45 Vertical Bend NTD 204 PL 204mm x 60mm Insulated Plenum NTD 204 1M 204mm x 60mm Insulated Duct 1m Length NTD...

Page 8: ...45H 220mm x 90mm Insulated 45 Horizontal Bend NTD 220 90V 220mm x 90mm Insulated 90 Vertical Bend NTD 220 45V 220mm x 90mm Insulated 45 Vertical Bend NTD 220 PL 220mm x 90mm Insulated Plenum to 125mm...

Page 9: ...lated 220 x 90 to 125mm Rectangular to Round In line Adaptor NTD 220 STR150 220 x 90 to 150mm Dia Insulated 220 x 90 to 150mm Rectangular to Round In line Adaptor Part Number Duct Size Description Par...

Reviews: