NuAire MRXBOXAB-ECO4-1ZOHSC Installation Manual Download Page 3

3

30. 06. 21. Document Number  671864

Nuaire | 

Western Industrial Estate 

Caerphilly 

CF83 1NA 

|

 

nuaire.co.uk

MRXBOXAB-ECO4-1Z(SC/SW)

Installation Manual

3.4 Condensate Drain

An additional straight multi-fit connector is included with the ancillary 
items supplied to extend the condensate drain connection of the MVHR 
unit outside the enclosure. The threaded connector should be coupled 
to the corresponding connection of the MVHR unit through the square 
cut out in the base panel of the enclosure.  Care should be taken to not 
over tighten this joint as this may result in the inner drain connection 
coming loose making removal difficult if required in the future.

The threaded nut can then be removed from the multi-fit connector 
and the adhesive backed cover plate passed over the multi-fit 
connector and affixed to the enclosure base panel (Figure 6).

The condensate must be discharged under a water level in a U-trap 
drainpipe or an alternative drain method which acts as an airlock. 

The condensate discharge drain is a 32mm male threaded 
connection. 

If using a U-trap, please ensure the U-trap has been filled to a 
suitable level of water to avoid any air locks.

If the condensation pipe is fitted in an unheated space the pipe 
should be in insulated to prevent freezing.

Nuaire recommend MVHR-DRAIN be used as the primary 
condensate take-off (Figures 8 and 9).

3.5 Extract / Input Areas

The unit is designed to extract air from all wet rooms e.g. bathroom, 
kitchen, en-suite, utility room (with sink).  WC’s do not need to be 
ventilated if openable windows are fitted.

Supply air should be to all habitable rooms e.g. bedrooms and lounge. 
Extract / input grilles should be adjustable valve types (not supplied). 
External grilles are to have a minimum free area of 12,250 mm

2

.

 
 

=

=

=

726

=

41

0

10

143

48

48

38

70

60

Summer / Winter Cable entry point.

Mains Cable Connection

Note: 
Any Items being accomodated in structure design should 
include sufficient clearance to allow for assembly tolerances 
and for ease of installation when positioning on site.

43

43

21

Condensate drain connection

(standard hand configuration). 

For opposite hand configuration position 

will be mirrored to the other side.

4x M10 Flanged head bolts 
protruding from base to be 

accomodated in structure design.

2x Rivet Heads

4x M8 Mounting Points

2x Hatched regions details 
compulsory support areas, 
further support may be required 
depending on structure design 
(supplied by others).

Mounting Points

B

B

Multi-fit 

Connector

Cover Plate

Enclosure 
Base Panel

Condensate Connection

Min 5

Drop

Condensate Trap Installation

Condensate pipe connection to 
unit and a typical example of a 
“U” trap drainpipe 

(Standard 

configuration only).

Summary of Contents for MRXBOXAB-ECO4-1ZOHSC

Page 1: ...y a person responsible for their safety Children shall not play with the appliance Cleaning and user maintenance shall not be carried out by children 1 1 Hazard Symbols REFER TO INSTRUCTION MANUAL Read and understand the installation and maintenance manual before installing operating or maintaining this product 1 2 Important Information This manual contains important information on the safe and ap...

Page 2: ...use long term damage to the unit and building fabric This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person for their safety Children should be supervised so that they do not play with the appli...

Page 3: ... in insulated to prevent freezing Nuaire recommend MVHR DRAIN be used as the primary condensate take off Figures 8 and 9 3 5 Extract Input Areas The unit is designed to extract air from all wet rooms e g bathroom kitchen en suite utility room with sink WC s do not need to be ventilated if openable windows are fitted Supply air should be to all habitable rooms e g bedrooms and lounge Extract input ...

Page 4: ...t and the air outlet duct from the unit these ducts should be insulated Ducting must be installed in such a way that resistance to airflow is minimised Bends should be kept to a minimum A minimum distance of 300mm between the appliance and any bends in ductwork is recommended Ideally 150mm diameter or 220 x 90mm rectangular ducting should be used refer to dwelling design drawing Figures 11 12 Duct...

Page 5: ...te e g boost should be at least the greater of step 1 and step 2 Note that the maximum individual room extract rate should be at least those given in ADF 2010 Extract Ventilation Rates table The minimum air supply rate should be at least the whole building ventilation rate found in step 1 For Scotland refer to BRE Digest 398 For further information refer to Domestic Ventilation Compliance Guide ww...

Page 6: ...ipe with min 5 o fall running to SVP MVHR unit Nuaire MVHR DRAIN Condensate drain uninsulated drain pipe with min 5 o fall running to SVP 3 10 2 Rectangular Ducting 12 Typical Rectangular Ducting Arrangement For Wall Mounted Units Air supply to lounge in ceilings via AirValve Extract air from kitchen bathroom in ceilings via AirValve Exhaust air from kitchen bathroom to outside via louvre grille M...

Page 7: ...the fixed wiring in accordance with the wiring regulations and shall have a minimum contact separation of 3mm 4 2 1 Unit Only MAINS 230V 50Hz N L 3 Position Switch Ancillary code MRXBOX95 3SWITCH Blue Green yellow Brown Black Supply cord from unit Grey L 1 2 5A Fuse BS1362 2 Pole Isolator 14 Wiring Diagram Unit Only 4 2 2 Unit Serving One Bathroom 15 Wiring Diagram One Bathroom 5A Fuse BS1362 MAIN...

Page 8: ...cover 6 0 CONTROLS 6 1 Humidity Adjustment This product contains an internal humidity sensor fitted into the air flow extracting from the wet rooms When the unit senses that the humidity exceeds the set point the unit will boost to that set by the commissioned boost speed The set point can be found on the front of the unit Figure 18 and is at its least sensitive when turned fully clockwise Note th...

Page 9: ...ication plate attached to the unit casing Telephone 02920 858 400 aftersales nuaire co uk Technical or commercial considerations may from time to time make it necessary to alter the design performance and dimensions of equipment and the right is reserved to make such changes without prior notice 7 0 MAINTENANCE It is important that maintenance checks are recorded and that the schedule is always ad...

Page 10: ...10 30 06 21 Document Number 671864 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOXAB ECO4 1Z SC SW Installation Manual NOTES ...

Page 11: ...11 30 06 21 Document Number 671864 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOXAB ECO4 1Z SC SW Installation Manual NOTES ...

Page 12: ...12 30 06 21 Document Number 671864 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOXAB ECO4 1Z SC SW Installation Manual NOTES ...

Reviews: