NuAire MRXBOXAB-ECO-LP1-OHSW Installation And Maintenance Manual Download Page 5

5

nuaire.co.uk 

029 2085 8400

19. 08. 19. Leaflet Number  671858

Installation and Maintenance

MRXBOXAB-ECO-LP1SW Mechanical Ventilation Unit with Heat Recovery

5.0 DIMENSIONS (mm) OPPOSITE HAND CONFIGURATION

6.0 DUCTING ARRANGEMENTS, OPPOSITE HAND CONFIGURATION

700

View from top (A)

668 hole cent

res

View from control side

900 

37

1

850

885 hole centres 

153

End view

200

67

(B)

(A)

600 

Spigot 2.

View from underside with cover removed (B)

Air

Supply 

Spigot 3.

Extract 

Air

Spigot 4.

Air

Exhaust 

Spigot 1.

Air

250

Intake 

Heat 

exchanger

Bypass 

chamber

Supply

fan

Extract

fan

21.5mm condensate pipe

Drip tray 

Wire

frame

filter

Wire

frame

filter

Bypass 

4.

damper 

1.

2.

3.

735 (Filter access distance)

Removable

access

filter

Removable

access

filter

69

96.4

342

Required
working 
space

Supply air to 

lounge via

in ceilings.

Air Valve  

Extract air from 

kitchen via 

in ceilings.

Air Valve  

Supply air to 

bedrooms via

in ceilings.

MVHR-DRAIN 

Air Valve  

condensate drain,

running to SVP.

mounted unit.

Nuaire ceiling void 

Extract air from 

bathroom via 

in ceilings.

Air Valve  

Exhaust air from 

kitchen/bathroom to 

outside via air brick.

Supply and extract 

ducts from external 

air bricks to the unit 

needs to be insulated.

Top of ceiling void.

Minimum distance as 

specified in Building 

Regulations. 

Intake air from 

outside via air brick.

Figure 9. Also shows the working space required.

Figure 10. Typical side view example of a (standard unit) mounted in a ceiling void using 204 x 60mm rectangular ducting and air valves.

Summary of Contents for MRXBOXAB-ECO-LP1-OHSW

Page 1: ...that they do not play with the appliance 2 0 INSTALLATION Installation must be carried out by competent personnel in accordance with the appropriate authority and conforming to all statutory governing...

Page 2: ...pipe cutter 2 Remove any swarf from the end of the plastic pipe Ream the copper pipe end to remove any burr and file if necessary to remove any external sharp edges Mark the socket depth on the pipe a...

Page 3: ...imum high rate from Table 1 For sanitary accommodation only as an alternative the purge ventilation provisions given in ADF 2010 can be used where security is not an issue In this case minimum high ex...

Page 4: ...1 2 3 735 Filter access distance Removable access filter Removable access filter 69 96 4 342 Required working space Supply air to lounge via in ceilings Air Valve Extract air from kitchen via in ceil...

Page 5: ...mper 1 2 3 735 Filter access distance Removable access filter Removable access filter 69 96 4 342 Required working space Supply air to lounge via in ceilings Air Valve Extract air from kitchen via in...

Page 6: ...only as the connections above are factory fitted Connection to Remote Fail Indicator Ref MRXBOX95 RFI optional Fuse 2A MAINS 230V 50Hz light Room Light switch Double Pole N L 3 Pole isolator Kitchen...

Page 7: ...Intake and extract temperatures are monitored at the point the airflows enter the unit if the range falls within the set parameters the bypass damper is opened automatically to target an indoor comfo...

Page 8: ...on planned maintenance being undertaken This warranty is void if the equipment is modified without authorisation is incorrectly applied misused disassembled or not installed commissioned and maintaine...

Reviews: