NuAire MRXBOX-VSC Installation & Operating Instructions Manual Download Page 7

8.0 Dimensions (mm)

Unit Dimensions  

E

F

145

85

35

6

73

57

9.0 Warranty

The 5 year warranty commences on the day of delivery and
includes parts and labour for the first year.
The remaining period covers replacement parts only.
The labour content is subject to full, free and safe access to the
equipment as recommended by the CDM regulations.
The warranty excludes any damage to the LCD touch screen
caused by misuse of a sharp object.

10.0 Service Enquiries

Nuaire can assist you in all aspects of service. Our Technical
Support Department will be happy to provide any assistance
required.

Technical Support

on 029 2085 8400

11.0 Compatibility with Ecosmart Fans

The MRXBOX-VSC controller is 100% compatible with the
Ecosmart fans and air handling units supplied with the controller. 
However, some other products may not be so.
Please check the suitability of the fan unit before upgrading the
existing user control to the MRXBOX-VSC controller.

To check if the fan is suitable for upgrade, please contact Nuaire
with detail of the fan code and the serial number printed on the
rating label.

12.0 User Guide

7

Installation and Operating Instructions

MRXBOX-VSC

User Control

09. 03. 16. Leaflet Number 671703

Technical or commercial considerations may, from time to time, make it necessary to alter the design, performance and 

dimensions of equipment and the right is reserved to make such changes without prior notice.

Note: This unit contains a
small lithium battery and
must be disposed of by a 
suitable recycling centre.

Do not dispose of with 
normal household waste.
Do not burn.

A

C = Surface 

mounting

depth

B

E = Screen 

width

F = Screen

depth

D = Recessed 

mounting

depth

Summary of Contents for MRXBOX-VSC

Page 1: ...0 Installation INSTALLED ENVIRONMENT 0 40o C and up to 90 RH non condensing Caution The unit must be installed away from any direct source of heat e g radiators and not in areas where it would be subjected to steam or water spray The mounting surface must be free from vibration The unit is supplied with back box suitable for surface mounting see Figs 1 5 If semi recess final projection from wall i...

Page 2: ...ons MRXBOX VSC User Control 09 03 16 Leaflet Number 671703 Commissioning screens for systems set up PIN controlled Maintenance used to reset filter change time User Options Access for User Guide Diagnostics used in the event of a fault Status Indication Speed Indicator Adjustment Outside Temperature Filter Change Warning Average Indoor Temperature Access to Function Screens Time ...

Page 3: ...es Alternatively if NONE is selected the unit will stay at the speed chosen permanently Note The speed of the unit may also be controlled by other sensors fitted some of which may have built in run on functionality 4 4 Summer Bypass Summer Bypass When the weather is warm outside the unit will automatically go into summer bypass mode meaning the air coming into your home will not pass through the h...

Page 4: ...ad of going straight into full boost 4 6 Holiday Mode Holiday Mode Allows you to set the ventilation system to run at a minimum level while you are away You can adjust the number of days you are away for with a maximum of 21 days 4 Installation and Operating Instructions MRXBOX VSC User Control 09 03 16 Leaflet Number 671703 ...

Page 5: ...ation Part F ventilation and detailed in the Installation instructions for the unit Speed 3 is for purge ventilation and is recommended to be set to 100 Note Speed 2 cannot be adjusted to a lower value than speed 1 5 2 Frost Protection Frost Protection In the event of the outdoor temperature falling below a set rate to unit reduces the supply fan speed down to a minimum to prevent the unit freezin...

Page 6: ... task has been completed the feature can be reset from the maintenance screen to clear the icon Instructions on how to complete this task can also be found on this screen 7 0 Diagnostics Diagnostics If a fault is suspected the diagnostics screen can be accessed to view the status of the unit controls a cross indicates an issue In the case that the communication is lost to the unit a will be shown ...

Page 7: ...fans and air handling units supplied with the controller However some other products may not be so Please check the suitability of the fan unit before upgrading the existing user control to the MRXBOX VSC controller To check if the fan is suitable for upgrade please contact Nuaire with detail of the fan code and the serial number printed on the rating label 12 0 User Guide 7 Installation and Opera...

Page 8: ...lly CF83 1NA t 44 0 29 2085 8400 f 44 0 29 2085 8444 e info nuaire co uk www nuaire co uk As part of our policy of continuous product development Nuaire reserves the right to alter specifications without prior notice Telephone calls may be recorded for quality and training purposes ...

Reviews: