NuAire MRXBOX-VSC Installation & Operating Instructions Manual Download Page 1

MRXBOX-VSC

Visual System User Control

Installation & Operating Instructions

Due to the higher current consumed by the
MRXBOX-VSC, the max cable run between
the fan control and the MRXBOX-VSC must
be limited to 50m.

1

Nuaire Limited

Western Industrial Estate  Caerphilly  United Kingdom  CF83 1NA  

T: 029 2085 8400  F: 029 2085 8444  E: [email protected]   W: www.nuaire.co.uk

The EMC Directive 
2004/108/EC  
The Low Voltage 
directive 
2006/95/EC

Remove the bezel and 2 screws to detach front 
of unit from 
back box.

10m sensor connection
wire (supplied).

Clearance aperture for wire
should be approx 20mm dia
to allow passage of plug end.
Allow approx 120mm of wire 
through for fitting to the 
backplate.

Wire can be located behind
a wall panel or fixed to wall 
surface.

Wall

To fan connector 
box terminal 
marked NET

Plug end mounted into the PCB socket inside 
the front half of the unit. Note that the data 
cable socket is 
positioned at 
the top corner 
of the unit.

Figure 1.

Figure 2.

Figure 3.

Figure 4.

Figure 5.

 

Fix back box  
to wall using 
screws.

Feed cable 
through hole 
in back box.

Bezel 

Front of unit.

Back box.

Bezel 

Front of unit

Back box.

TOP

09. 03. 16. Leaflet Number 671703

MRXBOX-VSC is a user control from the

Ecosmart range.

They have a 3.5in colour LCD touchscreen 

display to provide improved user interface.

The unit can be surface or semi-recessed 

mounted and is compatible with standard 

2-gang recess back box.

MRXBOX-VSC

– the unit is all plastic 

construction and supplied with 10m of 

pre-plugged connection cable and surface

mounting back box.

The units are SELV (12V d.c.) with the power

supplied from the fan unit via the pre-plugged

cable.

1.0 Installation

INSTALLED ENVIRONMENT

0-40

o

C and up to 90% RH non-condensing.

Caution: The unit must be installed away 
from any direct source of heat (e.g. radiators) 
and not in areas where it would be subjected 
to steam or water spray.

The mounting surface must be free from 
vibration.

The unit is supplied with back box suitable for

surface mounting. (see Figs. 1 - 5).

If semi-recess (final projection from wall is

7mm approx) is needed, a proprietary 2-gang

back box (25mm deep min.) may be used. 

Always physically check the suitability of the

back box before fitting. 

In some instances, the earthing point of the

back box may foul the unit and need to be

removed.

a) Fix one end of the 10m cable to the fan’s

Ecosmart connection point and route the

cable to the mounting position.

b) Unclip the front bezel from the unit and

remove the 2 retaining screws, then remove

the working section from the back box. (see

Fig. 2).

c) Feed the cable through the knock-out hole

in the base of the back box and mark the 

fixing point on the wall. 

Drill appropriately sized holes at the fixing

points and insert the wall plugs. 

Fix the back box on to the wall. (see Fig 3).

d) Plug the data cable into the socket. 

(see Fig. 4).

e) Fix the unit back into the back box using

the screws supplied, then clip the bezel back

on the unit again noting which way is up. 

(Top is printed on the inside face of the bezel

and and middle section). (see Fig. 5).

2.0 Data Cable Installation

A 4-core SELV data cable is used to connect

the control to the fan. 

Do not run data cable in the same conduit

as the mains cables and ensure there is a

50mm separation between the data cable

and other cables.

For cable lengths in excess of 10m a

MRXBOX-JB will be required to provide 

sufficient power. Keep the number of cable

joints to a minimum to ensure the best data

transmission efficiency between devices.

Summary of Contents for MRXBOX-VSC

Page 1: ...0 Installation INSTALLED ENVIRONMENT 0 40o C and up to 90 RH non condensing Caution The unit must be installed away from any direct source of heat e g radiators and not in areas where it would be subjected to steam or water spray The mounting surface must be free from vibration The unit is supplied with back box suitable for surface mounting see Figs 1 5 If semi recess final projection from wall i...

Page 2: ...ons MRXBOX VSC User Control 09 03 16 Leaflet Number 671703 Commissioning screens for systems set up PIN controlled Maintenance used to reset filter change time User Options Access for User Guide Diagnostics used in the event of a fault Status Indication Speed Indicator Adjustment Outside Temperature Filter Change Warning Average Indoor Temperature Access to Function Screens Time ...

Page 3: ...es Alternatively if NONE is selected the unit will stay at the speed chosen permanently Note The speed of the unit may also be controlled by other sensors fitted some of which may have built in run on functionality 4 4 Summer Bypass Summer Bypass When the weather is warm outside the unit will automatically go into summer bypass mode meaning the air coming into your home will not pass through the h...

Page 4: ...ad of going straight into full boost 4 6 Holiday Mode Holiday Mode Allows you to set the ventilation system to run at a minimum level while you are away You can adjust the number of days you are away for with a maximum of 21 days 4 Installation and Operating Instructions MRXBOX VSC User Control 09 03 16 Leaflet Number 671703 ...

Page 5: ...ation Part F ventilation and detailed in the Installation instructions for the unit Speed 3 is for purge ventilation and is recommended to be set to 100 Note Speed 2 cannot be adjusted to a lower value than speed 1 5 2 Frost Protection Frost Protection In the event of the outdoor temperature falling below a set rate to unit reduces the supply fan speed down to a minimum to prevent the unit freezin...

Page 6: ... task has been completed the feature can be reset from the maintenance screen to clear the icon Instructions on how to complete this task can also be found on this screen 7 0 Diagnostics Diagnostics If a fault is suspected the diagnostics screen can be accessed to view the status of the unit controls a cross indicates an issue In the case that the communication is lost to the unit a will be shown ...

Page 7: ...fans and air handling units supplied with the controller However some other products may not be so Please check the suitability of the fan unit before upgrading the existing user control to the MRXBOX VSC controller To check if the fan is suitable for upgrade please contact Nuaire with detail of the fan code and the serial number printed on the rating label 12 0 User Guide 7 Installation and Opera...

Page 8: ...lly CF83 1NA t 44 0 29 2085 8400 f 44 0 29 2085 8444 e info nuaire co uk www nuaire co uk As part of our policy of continuous product development Nuaire reserves the right to alter specifications without prior notice Telephone calls may be recorded for quality and training purposes ...

Reviews: