MRXBOXAB-ECO(3/5)-(OH)SW

Installation Manual

1.2 Important Information

This manual contains important information on the safe and 
appropriate assembly, transport, commissioning, operation, 
maintenance, disassembly and simple troubleshooting of the product.

While the product has been manufactured according to the accepted 
rules of current technology, there is still a danger of personal injury or 
damage to equipment if the following general safety instructions and 
the warnings contained in these instructions are not complied with.

Read these instructions completely and thoroughly before 
working with the product.

Keep these instructions in a location where they are accessible 
to all users at all times.

Always include the operating instructions when you pass the 
product on to third parties.

1.3 Personal Protective Equipment

The following minimum Personal Protective Equipment (PPE) is 
recommended when interacting with Nuaire product:

Protective Steel Toed Shoes - 

when handling heavy objects.

 

Full Finger Gloves (Marigold PU800 or equivalent) - 

when 

handling sheet metal components. 

Semi Fingerless Gloves (Marigold PU3000 3DO or equivalent) 

- when conducting light work on the unit requiring tactile 
dexterity. 

Safety Glasses

 - when conducting any cleaning/cutting operation 

or exchanging filters. 

Reusable Half Mask Respirators 

- when replacing filters which 

have been in contact with normal room or environmental air.

Nuaire would always recommend a site specific risk assessment by a 
competent person to determine if any additional PPE is required. 

2.0 INTRODUCTION

The ECO(3/5) wall mounted range of units is designed to provide 
mechanical supply and extract ventilation with heat recovery. 

The unit is fitted with two independent fans. Each fan has full speed 
control for background and boost ventilation rates. To recover heat 
from the extract air the heat exchanger block is utilised. The heat 
exchanger can recover up to 95% of the normally wasted heat.

3.0  MECHANICAL INSTALLATION

Installation must be carried out by competent personnel in accordance 
with the appropriate authority and conforming to all statutory 
governing regulations. All mains wiring must be in accordance with the 
current I.E.E. Regulations, or the appropriate standards. Ensure that the 
mains supply (Voltage, Frequency and Phase) complies with the rating 
label. 

Please note a clear working space is required around the installed unit 
to allow the cover to be removed and provide sufficient access for 
maintenance such as filter change.

Please allow a minimum of 360mm in front of an  
MRXBOXAB-ECO(3/5) unit.

The fan must be installed indoors, on a suitable wall away from direct 
sources of frost, heat and water spray or moisture generation. For a 
vibration-free result the unit must be mounted to a solid wall.

The unit must remain switched on at all times to maintain 
ventilation within the dwelling. Turning the unit off will cause long 
term damage to the unit and building fabric.

Airflow Through unit (Standard Unit)

Airflow Through OH unit (Opposite Hand Unit)

Wall Mounting Bracket

Mounting Unit Onto Bracket

3.1 Wall Mounting

If fitting the MVHR in conjunction with a MRXBOX-AV(3/5) the 
hanging brackets supplied with the MVHR are redundant and 
should not be used. The installation instructions supplied with 
MRXBOX-AV(3/5) should be followed. 

The unit is designed for wall mounting, only on a solid wall. A 
gypsum block or stud/plasterboard wall will not suffice.

1. One part of the mounting bracket (supplied) should be offered up 

to the wall, ensuring it’s located horizontally. Mark the fixing points 
through the pre drilled holes in the bracket and install with screws 
(by others), whilst ensuring the interlock side is at the top (Figure 3).

2. Install the unit on the wall by ensuring the bracket fixed to the rear 

of the unit interlocks over the wall mounted bracket (Figure 4).

Care must be taken to ensure the unit is installed true in all 3 
dimensions. Failure to do so may result in overflow from the 
internal condensation drip tray.

Extract air 
from house

Intake air 

Exhaust air 

from outside

to outside

from house

to house

Supply air 

Intake air 
from outside

Extract air 
from house

Supply air 
to house

Exhaust air 
from house
to outside

Extract air 
from house

Intake air 

Exhaust air 

from outside

to outside

from house

to house

Supply air 

Intake air 
from outside

Extract air 
from house

Supply air 
to house

Exhaust air 
from house
to outside

Summary of Contents for MRXBOX-ECO3

Page 1: ...corporated within the fixed wiring and shall have a minimum contact separation of 3mm in accordance with latest edition of the wiring regulations This unit must be earthed Ducting must be securely fix...

Page 2: ...e appropriate authority and conforming to all statutory governing regulations All mains wiring must be in accordance with the current I E E Regulations or the appropriate standards Ensure that the mai...

Page 3: ...th centres of no more than 400mm Add additional vertical supports if necessary Height wise ideally the MDF panel should extend from floor to ceiling but as a minimum should be a least 2m high Fix the...

Page 4: ...mmodation 6 l s Whole Dwelling Ventilation Rates Number Of Bedrooms In Dwelling 1 2 3 4 5 Whole dwelling ventilation rate l s 1 2 13 17 21 25 29 Notes 1 In addition the minimum ventilation rate should...

Page 5: ...as follows The maximum whole dwelling extract ventilation rate e g boost should be at least the greater of step 1 and step 2 Note that the maximum individual room extract rate should be at least those...

Page 6: ...insulated Insulated supply duct Top of ceiling void Air supply to bedrooms in ceilings via Air Valve mounted unit Nuaire wall MVHR DRAIN Condensate drain uninsulated drain pipe with min 5o fall runnin...

Page 7: ...he two screws the Ecosmart cable can then be connected to the underside of the MVHR unit within The cable should be fed through rubber blanking plug to provide a seal when the cover is re fitted 4 3 W...

Page 8: ...s on the front cover The variants are listed below The display on the unit control panel will not indicate when a higher speed setting has been triggered by an external source such as an ES PIR2 etc 1...

Page 9: ...orrectly applied misused disassembled or not installed commissioned and maintained in accordance with the details contained in this manual and general good practice The product warranty applies to the...

Page 10: ...10 23 07 20 Document Number 671856 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOXAB ECO 3 5 OH SW Installation Manual NOTES...

Page 11: ...11 23 07 20 Document Number 671856 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOXAB ECO 3 5 OH SW Installation Manual NOTES...

Page 12: ...12 23 07 20 Document Number 671856 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOXAB ECO 3 5 OH SW Installation Manual NOTES...

Reviews: