DELIVERY SET

  

The delivery set includes:  
1. Fan - 1 pce;  
2. Screws and dowels - 4 pcs;  
3. Plastic screwdriver (only for modifications with timer) - 1 pce;  
4. User's manual;  
5. Packing box.  

SHORT DESCRPTION  

The product described herein is a mixed-flow inline fan for supply or extract ventilation of premises 
heated during winter time.  

The fan is rated for connection to 100, 125, 150, 160, 200, 250 and 315 mm.  
The fan is equipped with a two-speed motor.  

ILM+ XXX - basic modification;  
ILM+ XXX 

V

 - modification with a built-in speed switch;  

ILM+ XXX RV - modification with a built-in speed switch and power cable with a plug (fig. 3

1

);  

ILM+ XXX T - modification with a off-delayed timer regulated from 2 to 30 minutes (fig. 3

0

);  

ILM+ XXX U(U1) - modification with a speed controller with electronic thermostat, 
built-in temperature sensor and power cable with a plug (fig. 3

2

);  

ILM+ XXX Un (U1n) - modification with a speed controller with electronic thermostat, 
external temperature sensor and power cable with a plug (fig. 3

2

);  

ILM+ XXX P - modification with a speed controller and a power cord with a plug (fig. 3

3

).  

XXX - spigot diameter.  

Due to constant improvements the design of some models may slightly differ from that one described in this manual.

3

Read the present user's manual carefully before proceeding with installation works. 
Compliance with the manual requirements ensures reliable operation and long 
service life of the product.  Keep the user's manual available as long as you use 
the product. You may need to re-read the information on the product servicing.  

!

ATTENTION

Summary of Contents for ILM+ P Series

Page 1: ...IN LINE MIXED FLOW FANS Nuaire ILM USER S MANUAL www nuaire co uk 2017...

Page 2: ...hysical mental or sensory capacities without proper practical experience or expertise unless they are controlled or instructed on the product operation by the person s responsible for their safety Do...

Page 3: ...rom 2 to 30 minutes fig 30 ILM XXX U U1 modification with a speed controller with electronic thermostat built in temperature sensor and power cable with a plug fig 32 ILM XXX Un U1n modification with...

Page 4: ...ver for fan settings adjustments Use the screwdriver to alter the turn off delay time or the humidity threshold Do not use a screwdriver knife etc for adjustment operations not to damage the circuit b...

Page 5: ...G The fan is suitable both for horizontal or vertical mounting on the floor on the wall or on the ceiling fig 2 as one unit or included into connected in parallel In case of the horizontal fan mountin...

Page 6: ...acid or alkali vapours that may cause corrosion of the product parts WARRANTY ILM units have a 1 year warranty The warranty starts from the day of delivery and includes parts and labour for the first...

Page 7: ...e product in case of replacing and using parts units and components of the product not prescribed by the manufacturing company in case of other use of the product other than intended use in case of th...

Page 8: ...tions of third persons an accident or force majeure circumstances The manufacturing company shall not be responsible for damage to health and property of the customer caused by the customer s violatin...

Page 9: ...9 2 min 1 m...

Page 10: ...10 5 3 6 4 MOUNTING QF...

Page 11: ...9 7 8 11 10 11...

Page 12: ...13 14 15 16 17 18 19 ILM 100 125 ILM 150 160 200 250 315 MAX MIN MAX MIN MAX MIN MAX MIN N L2 N L QF X N L1 N L QF X QF N L1 L2 S N L X L2 L L1 N X N L2 X N L QF N L1 X N L QF QF N L1 L2 S N L X L2 L...

Page 13: ...k for 5 contacts terminal block for 4 contacts N L ST QF N L LT L1 X S N L ST QF N L LT L1 X L2 N L ST QF N L LT X N L ST QF N L LT L1 X S N L ST QF N L LT L1 X N L ST QF N L LT L2 X terminal block fo...

Page 14: ...14 27 24 25 26 28 29 QF...

Page 15: ...15 31 30 30 min 2 min X MIN MAX STOP...

Page 16: ...16 33 32 speed control knob thermostat control knob min max ILM U U1 ILM Un U1n speed control knob...

Page 17: ...36 34 37 35 17...

Page 18: ...18 40 38 41 39...

Page 19: ......

Page 20: ...0 315 V RV T U P 1 n ACCEPTANCE INFORMATION Fan is ready for using Acceptance stamp Date of production Sold name of trade enterprise and stamp of the shop Date of sale mark the proper model only www n...