FLAT2000 L/R

Installation Manual

Side Input Installation (Front View)

Alternative
spigot positions
(inlet only)

FLATMASTER

Input grille (louvres 
slant downwards)

100mm dia / 121x60mm rectangular ducting

(note input side kept as short as possible)

100mm dia / 121x60mm 

rectangular ducting

Outside wall

Room
(typical)

Hallway
(typical)

Discharge
grille (note
louvres 
slant 
upwards)

Minimum
height 1.8m

 

 

Rear Input Installation (Top View)

FLATMASTER

Note alternative
inlet spigot positions

Outside wall

Hallway
(typical)

Air input

100mm dia ducting

Air
discharge

Minimum

height 1.8m

3.5 Inlet / Outlet Grille Installation

If a fly screen is fitted it should be removed from both the internal and 
external grille.

When installing the internal grille, the louvres must slant 
upwards to ensure the correct air circulation and the avoidance of 
unpleasant down draughts. The outside wall input grille louvres 
must slant downwards.

Standard 100mm diameter ducting or 121 x 60mm ducting is used to 
connect the Flatmaster to the input and discharge grilles.

Any air intake terminal MUST be installed in accordance with the 
appropriate regulation.

As a guide, the BS5440 series of British Standards deals with this 
issue and currently states that an air intake must be at a minimum 
distance of 300mm from a gas boiler balanced flue. Installers are 
advised to be aware of the requirements of this standard when 
installing ‘through the wall’ supply air ducting. Similarly, supply 
and extract air grilles should be at least 300mm apart.

The internal grille must not be placed within 1.5m of a smoke 
alarm.

4.0 DIMENSIONS(mm)

Dimensions for the space required can be determined from the 
dimensions shown in Figure 10 below.

Allow an additional 32mm for the length of each end spigot and any 
additional room for installation and maintenance e.g. access to screws 
on top and bottom of unit for front cover.

10 

Unit Dimensions

485

100mm dia. or 121 x 60mm
 interchangeable spigots supplied with unit

Alternative inlet
end spigots

320

160

Alternative end 
spigot panels

100mm dia.
spigot shown

121 x 60mm rectangular
spigot indicated 

Alternative (knock out)
spigot positions
on rear face 100mm dia. only 

15mm

100mm dia. spigot
(103mm dia. x 6mm 
shoudler at base of spigot)

32

32mm from edge
of spigot shoulder

186.5

148

241

52

267mm
between 
feet 

Front view

End view

Back view

Summary of Contents for FLAT2000 L

Page 1: ...cturer its service agent or similarly qualified persons in order to avoid a hazard The replacement cord must be of the same technical specification as the original cord or greater Precautions must be taken to avoid the back flow of gases into the room from the open flue of gas or other fuel burning appliances This appliance should not be used by children or persons with reduced physical sensory or...

Page 2: ... unit is supplied arranged for LEFT HAND discharge of air The FLAT2000R unit is supplied arranged for RIGHT HAND discharge of air Whilst the installation of the unit may be achieved by a suitable craftsman the provision of the electrical supply and the connection of the unit to the mains must be carried out by a qualified electrician 3 0 MECHANICAL INSTALLATION Installation must be completed by co...

Page 3: ...oving the front cover fixed by two screws with the third also requiring removal of the deflector plate assembly Position the unit on the wall where it is to be mounted and mark through the feet Drill and plug the wall with suitable fixings Remove the PCB cover and feed the electrical supply cable through the grommet hole in the rear of the unit standard 1mm three core lighting cable is recommended...

Page 4: ... discharge grilles Any air intake terminal MUST be installed in accordance with the appropriate regulation As a guide the BS5440 series of British Standards deals with this issue and currently states that an air intake must be at a minimum distance of 300mm from a gas boiler balanced flue Installers are advised to be aware of the requirements of this standard when installing through the wall suppl...

Page 5: ...al boost when required Main connection block PCB cover 5 4 Remote BOOST Switch Wiring A remote BOOST switch is supplied and provides a BOOST speed facility for additional ventilation on demand E N L optional lamp N L mains 230V 50Hz fan unit 3 pole isolator fuse 3A remote BOOST switch supplied 3 12 Boost Switch Wiring Diagram 5 5 Smoke Alarm Automatic Shut Down If the unit is required to switch of...

Page 6: ...tly applied misused disassembled or not installed commissioned and maintained in accordance with the details contained in this manual and general good practice The product warranty applies to the UK mainland and in accordance with Clause 14 of our Conditions of Sale Customers purchasing from outside of the UK should contact Nuaire International Sales office for further details Failure to maintain ...

Page 7: ...in Fused spur fitted Y N Fused rating fitted Amp 1 2 5 6 DD MM YYYY 15 Unit With Cover Installed 16 Schematic Of Spigot Configurations Within last 12 months 12 24 months ago More than 24 months ago Unknown General condition Ductwork intact Casing damaged Ductwork damaged Clean Light contamination Heavy contamination Clean Light contamination Heavy contamination Operational Clean Light contaminatio...

Page 8: ...8 16 10 20 Document Number 670901 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk FLAT2000 L R Installation Manual NOTES ...

Reviews: