2.7 ADF 2010 Ventilation Calculations
Design of MVHR Systems

The MVHR system has been sized for the winter period. Additional
ventilation may be required during the warmer months and it has
been assumed that the provisions for purge ventilation (e.g. openable
windows) could be used.

Step 1:

For any design air permeability, determine the whole dwelling

ventilation supply rate 

from Table 2.

As an alternative where the design air permeability is intended to be
leakier than (>) 5m

3

/(h.m

2

) 50 Pa, allow for infiltration for all

dwelling types by subtracting from the whole dwelling ventilation
supply rate 

from Table 2

; 0.04 x gross internal volume of the dwelling

heated space (m

3

).

Step 2:

Calculate the whole dwelling extract ventilation rate by 

summing the individual room rates for ‘minimum high rate’ 

from

Table 1.

(For sanitary accommmodation only, as an alternative, the purge 
ventilation provisions given in ADF 2010 can be used where security
is not an issue. In this case ‘minimum high extract rate’ for the 
sanitary accommodation should be omitted from the step 2 
calculation).

Step 3: 

The required airflow rates are as follows:

n

the maximum whole dwelling extract ventilation rate (e.g. boost) 
should be at least the greater of step 1 and step 2. 
Note that the maximum individual room extract rate should be 
at least those given

in table 1.

for minimum high rate.

n

the minimum air supply rate should be at least the whole building
ventilation rate found in step 1.

For Scotland refer to BRE Digest 398.

For further information refer to “Domestic Ventilation Compliance
Guide” www.planningportal.gov.uk/buildingregulations/approved
documents/partl/compliance

4

27. 11. 17. Leaflet Number 671733

Installation and Maintenance

The WM2 Wall Mounted Range of Units

70 6

6

1

1

448

5

5

172 CR S

144

417 CR S

=

=

if ancillary distribution box (DB-WM2) is to be used refer to documentation 
supplied with DB-WM2 as requirements will differ.

125.0

Ø

142  

UNI T WEI GHT =  45Kg

142

N

N)

Condensate drain 
connection
(opposite hand 
configuration)

Condensate drain connection
on centre line of unit

Condensate drain 
connection (standard 
configuration)

3.0 Dimensions 

Figure 9. 

Summary of Contents for ecosmart MRXBOX95-WM2-AE

Page 1: ...tatutory governing regulations All mains wiring must be in accordance with the current I E E Regulations or the appropriate standards Ensure that the mains supply Voltage Frequency and Phase complies with the rating label Please allow a minimum of 350mm in front of the unit The fan must be installed indoors on a suitable wall away from direct sources of frost heat water spray or moisture generatio...

Page 2: ...nd the cover plate slid along the length to bond against the base panel of the enclosure preventing noise breakout fig 7 Figure 7 1 The condensate must be discharged under a water level in a U trap drainpipe or an alternative drain method which acts as an airlock 2 If using a U trap please ensure the U trap has been filled to a suitable level of water to avoid any air locks 3 If the condensation p...

Page 3: ... the unit these ducts should be insulated Ducting must be installed in such a way that resistance to airflow is minimised Bends should be kept to a minimum A minimum distance of 300mm between the appliance and any bends in ductwork is recommended Ideally 150mm diameter or 220 x 90mm rectangular ducting should be used Refer to dwelling design drawing figure 10a and 10b on page 5 for further informa...

Page 4: ...case minimum high extract rate for the sanitary accommodation should be omitted from the step 2 calculation Step 3 The required airflow rates are as follows n the maximum whole dwelling extract ventilation rate e g boost should be at least the greater of step 1 and step 2 Note that the maximum individual room extract rate should be at least those given in table 1 for minimum high rate n the minimu...

Page 5: ...pply duct Air supply to lounge via Air Valve in ceilings Extract air from kitchen bathroom via Air Valve in ceilings Air supply to bedrooms via Air Valve in ceilings Top of ceiling void Top of ceiling void Nuaire wall mounted unit Air supply to bedrooms via Air Valve in ceilings Nuaire wall mounted unit MVHR DRAIN Condensate drain uninsulated drain pipe with min 5o fall running to SVP MVHR DRAIN C...

Page 6: ...ion to Remote Fail Indicator Ref MRXBOX95 RFI Optional 3 2 Figure 11a Note Wiring is for reference purposes only as the connections in fig 11a are factory fitted The unit is pre wired with a 2 metre fly lead Disconnection from the supply mains must be incorporated within the fixed wiring in accordance with the wiring regulations and shall have a minimum contact separation of 3mm Disconnection from...

Page 7: ...overing the control has an adhesive panel which should be removed post commissioning to prevent tampering 8 Speed 1 is limited to never exceed speed 2 when commissioning speed 2 should always be set first 6 1 Speed 3 The unit has to ability to override both speed 1 and speed 2 to operate the fan to maximum airflow See wiring diagram for details of operating this facility 6 2 Humidity adjustment AB...

Page 8: ...n label 11 0Warranty The 5 year warranty starts from the day of delivery and includes parts and labour for the first year and parts only for the remaining 4 years Thiswarrantyisvoidiftheequipmentismodifiedwithoutauthorisation isincorrectlyapplied misused disassembled ornotinstalled commissionedandmaintainedinaccordancewiththedetailscontained inthismanualandgeneralgoodpractice The product warranty ...

Reviews: