10.3 Selecting a Speed

When power to the unit is switched on (via the supplied isolator) the display will 
cycle though the outer segments (referred to as start-up pattern). Press the “up” 
or “down” switch to choose the flow rate appropriate to the property you are 
installing the unit in.

10.5 Setting the Temperature Speed Control Option

When delivered, the unit is set to temperature setting 1 as a default. To change 
this setting, switch the power to the unit on (via the supplied isolator). The 
display in the ceiling vent will show the start-up pattern for two minutes and the 
unit will being running at speed 6. In this time you can change the temperature 
setting by pressing and holding the “up” switch. The display will show a flashing 
value of 1 and will increase every 4 seconds. Once you have reached the tem-
perature setting you require press and release the “down” button to store the 
setting. The fan will now enter into its normal speed setting mode and a speed 
can be selected at this point.

9.0 SMOKE / CARBON MONOXIDE ALARM  
AUTOMATIC SHUT DOWN 

If the unit is required to switch off in the event of smoke/CO detection, alarms 
are available with separate relay bases from companies such as:

Dicon Safety products – www.diconsafety.co.uk
Aico Ltd – www.aico.co.uk
Note: This is a mandatory requirement for all units installed in a 3 Storey 
property.

DRIMASTER

FAN UNIT

Mains power Smoke/CO  detector

with NO/NC contacts

NO

NC

N

L

N

L

C

230V

Supply

230V

For information only, 
refer to manufacturer’s  
specific  instructions.

10.4 Setting the Temperature Set Point

A temperature sensor is fitted to the outlet of the heater and will control the 
heater output to maintain the set point. The set point ranges between 10˚C (ful-
ly anti-clockwise) and 20˚C (fully clockwise) and can be adjusted via the min/
max commissioning pot located on the ceiling vent diffuser.

10.2 Selecting a Speed

When power to the unit is switched on the display will show the temperature 
control option for 2 minutes. Once the start-up pattern has completed you may 
now press the “up” or “down” switch to choose the flow rate appropriate to the 
property you are installing the unit in.

10.0 CONTROL SETTINGS

Option

Temperature  Control Description

(Default)

At loft temperatures below 19°C the unit will operate on  

“Normal Operation Mode”.

  

At loft temperatures above 18°C but less than 24°C, the unit will 
switch automatically to 

“Intelligent Heat Recovery Mode”

At loft temperatures above 23°C the unit will switch itself auto-
matically to 

“Standby Mode”.

2

At loft temperatures below 19°C the unit will operate on 
 

“Normal Operation Mode”

At loft temperatures above 18°C but less than 31°C, the unit will 
switch automatically to 

“Intelligent Heat Recovery Mode”

At loft temperatures above 30°C the unit will switch itself auto-
matically to “Standby Mode”.

3

This option removes the temperature sensing function out of the 
unit.  
The unit will operate continuously in 

“Normal Operation 

Mode” 

depending on the volume control setting selected.

4

At loft temperatures below 16°C the unit will operate on  

“Normal Operation Mode”

At loft temperatures above 15°C but less than 28°C, the unit will 
switch automatically to 

“Heat Recovery Mode”

At loft temperatures above 27°C the unit will switch itself auto-
matically to 

“Standby Mode”

.

5

Not applicable for the HEAT model.

UP

DOWN

DriMaster-Eco

MIN

MAX

UP

DOWN

DriMaster-Eco

MIN

MAX

10.1 Speed Settings

The unit has 5 air flow rate (speed) settings, 2-6. Switches to control the speed 
settings and the display are located on the underside of the diffuser. The follow-
ing table shows the flow rates and their corresponding speed settings.

As an example a one bedroom bungalow should be set to speed 2, and a large 5 
bedroom detached property would require speed 6.

Speed Settings

Air flow rate 

(Litres/second)

0

Standby (0)

1

10*

2

20

3

30

4

40

5

50

6

60

* At speed 1 the heater will not be enabled.

IMPORTANT

In the event of conducted RF interference between 80 to 127 

MHz or transient radiated interference between 80 to 87 MHz, the 

unit may go into standby mode or the LED display may go blank and 

fan stop temporarily, then go into reset mode (LED flashing with the 

number of the speed setting) and run at high speed. The unit will re-

turn to normal after 2 minutes after the RF interference has stopped.