18. 10. 17. Leaflet Number 671679

Installation, Operating and Maintenance Instructions

8

.0 

   

Warranty

5 year warranty on Ecosmart models for peace of mind. The 
warranty starts from the day of delivery and includes parts and 
labour for the first year. The remaining period covers replacement 
parts only. 
This warranty is void if the equipment is modified without 
authorisation, is incorrectly applied, misused, disassembled, or not 
installed, commissioned and maintained in accordance with the 
details contained in this manual and general good practice. 

The product warranty applies to the UK mainland and in accordance 
with Clause 14 of our Conditions of Sale. Customers purchasing from 
outside of the UK should contact Nuaire International Sales office for 
further details.

9.

0  Spares for Dave Supply fans

Spare parts and replacement components are available from Nuaire

 

Ltd. Please contact us on the numbers below for further details.

G4  Filter 

Unit Size

Replacement Part No.

DS1A-*ES

D1A-G4FILTERKIT

DS2A-*ES

D2A-G4FILTERKIT

DS2HA-*ES

D2HA-G4FILTERKIT

DS3A-*ES

D3A-G4FILTERKIT

DS4A-*ES

D3A-G4FILTERKIT

DS4HA-*ES

D4HA-G4FILTERKIT

DS5A-*ES

D5A-G4FILTERKIT

DS6A-*ES

D6A-G4FILTERKIT

DS7A-*ES

D7A-G4FILTERKIT

F7 Filter

Unit Size

Replacement Part No.

DS1A-*ES

D1A-F7FILTERKIT

DS2A-*ES

D2A-F7FILTERKIT

DS2HA-*ES

D2HA-F7FILTERKIT

DS3A-*ES

D3A-F7FILTERKIT

DS4A-*ES

D3A-F7FILTERKIT

DS4HA-*ES

D4HA-F7FILTERKIT

DS5A-*ES

D5A-F7FILTERKIT

DS6A-*ES

D6A-F7FILTERKIT

DS7A-*ES

D7A-F7FILTERKIT

11.0 After Sales

For technical assistance or further product information,

 

including

 

spare parts and replacement components, please

 

contact the After

 

Sales Department.

Telephone 02920

 

858

 

400

 

DAVE Supply Fans (ES Models) 50/60Hz

Summary of Contents for DAVE Series

Page 1: ... are manufactured from aluzinc rectangular in section and have circular rigid spigots at each end All units are supplied with fixing brackets designed to simplify installation 1 0 Fan Unit Coding Descriptions 2 0 Handling Always handle the units carefully to avoid damage and distortion Care must be taken to ensure any slings used for hoisting do not damage the casing or the control module componen...

Page 2: ...5 190 DS3A EES H 1005 780 345 200 430 155 155 DS4A NES H 1005 840 370 250 370 150 100 DS4A LES H 1005 840 370 250 430 175 190 DS4A EES H 1005 840 370 250 430 155 155 DS4HA NES H 1005 840 370 250 370 150 100 DS4HA LES H 1005 840 370 250 430 175 190 DS4HA EES H 1005 840 370 250 430 155 155 DS5A NES H 1155 1110 1110 984 410 315 370 150 100 DS5A LES H 1155 984 410 315 430 175 190 DS5A EES H 1155 984 4...

Page 3: ...valve to a fully open position to allow full water flow through the coil and the main PCB will close the Heat demand contacts These contacts could be used to send a signal to activate the boiler and or valve to open to provide heat if not already doing so 4 1 2 Port Pressure Independent Balancing Control Valve Setting Instruction Fig 6 Remove Actuator Fig 7 Unlock Adjusting Collar Units 1 2 2H DN2...

Page 4: ...el details Note A Commissioning Procedure document leaflet No 671153 is available on request from Nuaire Tel 029 2088 5911 The Control Module Fig 12 The BMS connection is made with a plug in connector via the socket See figure 13 To ensure the connection is made only by suitably qualified and authorised personnel the plug is not supplied It is available from R S Components Part No 403 875 or Farne...

Page 5: ...ater Neutral Thermistor T Thermistor R Signal 0V Signal VE OIP 5V Note Customer connections for electric heater 40amp draw E N L L N E Heater Temperature Settings Note Customer connections for fan and control 5amp draw max 5 18 10 17 Leaflet Number 671679 Notes Local isolator by others All inter connections between circuit boards blowers and sensors are made at the factory Remove link wire if swit...

Page 6: ...OL COOLING CONTROL 0V SETPOINT 0 10V 10V 0V DEADBAND 0 10V 10V AUTO HEAT COOL OFF ON COOL SENSOR ACTUATOR CONTROL WHITE ACTUATOR CONTROL BLACK ACTUATOR CONTROL RED Note Customer connections for fan and control 5amp draw max 6 18 10 17 Leaflet Number 671679 Notes Local isolator by others All inter connections between circuit boards blowers and sensors are made at the factory Remove link wire if swi...

Page 7: ...nce Ensure all control components are secure and clean refit the cover Lubrication Motors are fitted with sealed for life bearings and do not require any lubrication Filter care replacement The filter where applicable will require cleaning on a regular basis The frequency of the cleaning operation will depend on the site conditions 7 0 Fan Components see fig 18 Key Components A Lid Base B Attenuat...

Page 8: ...es office for further details 9 0 Spares for Dave Supply fans Spare parts and replacement components are available from Nuaire Ltd Please contact us on the numbers below for further details G4 Filter Unit Size Replacement Part No DS1A ES D1A G4FILTERKIT DS2A ES D2A G4FILTERKIT DS2HA ES D2HA G4FILTERKIT DS3A ES D3A G4FILTERKIT DS4A ES D3A G4FILTERKIT DS4HA ES D4HA G4FILTERKIT DS5A ES D5A G4FILTERKI...

Page 9: ...nged so as not to bear on the casing 3 3 Equipment stored on site prior to installation should be protected from the weather and steps taken to prevent ingress of contaminants 4 0 OPERATIONAL LIMITS 4 1 It is important that the specified operational limits for the equipment are adhered to e g operational air temperature air borne contaminants and unit orientation 4 2 Where installation accessories...

Reviews: