Nuaire Group MRXBOX95B-LP1EH Installation And Maintenance Manual Download Page 5

S

W

L2     L 

   S

WL1 

  L 

  N

CN7 EXTRA

C

T
CN6 SUPPL

Y

BLU

WHI

YEL

RED

  

SUPPL

Y

B

Y

P

ASS

SUPPL Y F

AN

EXTRACT F

AN

B

L

U

B

R

N

B

R

N

B

L

U

EXTRAC

T FA

N

B

L

U

B

R

N

EXTERNAL PUMP

BLU

WHI

YELI

RED

 F

A

IL

CN8

TH1    TH2

L         N

 Supply  Supply Extract Extract
 Trickle  Boost 

 Trickle  Boost

CN5

Connection to Remote Fail 

Indicator Ref: MRXBOX95LH-RFI

3

2

Note: Wiring is for reference 
purposes only as the connections 
above are factory fitted.
The unit is pre-wired with a 
2 metre fly lead.

5

05. 09. 13. Leaflet Number 671632

Installation and Maintenance

MRXBOX95B-LP1EH Mechanical Ventilation with Heat Recovery & Summer Bypass

Fuse 2A

MAINS
230V
50Hz

Room
light

Light 

switch 

(Double 

Pole)

N

L

Fuse 2A

MAINS
230V
50Hz

Room
lights

Light 

switches 

(Double 

Pole)

N

L

3 Pole
isolator

3 Pole
isolator

Kitchen switch

Kitchen switch

Blue

Brown

Black

Optional summer boost switch

Supply cord
from unit

Green/yellow

Blue

Brown

Black

Supply cord
from unit

Optional summer boost switch

Grey

Grey

Green/yellow

Unit serving kitchen and bathroom

Unit serving kitchen and two bathrooms

Figure 8. 

Figure 9. 

For good EMC engineering practice, any sensor cables 

or switched live cables should not be 

placed within 50mm of other cables or on the same 

metal cable tray as other cables.

Figure 7.

6.0  Electrical Connection

Please note: the electrical connection of the unit must be be carried
out by a qualified electrician.

The unit is supplied with a flexible cord for connection to the mains
supply.

Electrical details:-

Voltage:

240V  1ph  50Hz

Consumption:  LP1EH - 1.3 Amp 

Fuse rating: 

3 Amp

NOTE This unit must be earthed.

The three core cable from the mains power supply should be 
connected to a fixed wiring installation, via a fused isolator, in
accordance with current IEE wiring regulations.

Disconnection from
the supply mains must
be incorporated within
the fixed wiring in
accordance with the
wiring regulations and
shall have a minimum
contact separation 
of 3mm.

Disconnection from
the supply mains must
be incorporated within
the fixed wiring in
accordance with the
wiring regulations and
shall have a minimum
contact separation 
of 3mm.

CN11 & CN12
Net Connections for
Ecosmart Devices.

Summary of Contents for MRXBOX95B-LP1EH

Page 1: ...mains wiring must be in accordance with the current I E E Regulations or the appropriate standards Ensure that the mains supply Voltage Frequency and Phase complies with the rating label Please note...

Page 2: ...d be adjustable valve types not supplied External grilles to have a minimum free area of 12 250 sq mm 2 3 Ducting Before commencing ducting installation reference should be made to building regulation...

Page 3: ...um high rate from Table 1 For sanitary accommmodation only as an alternative the purge ventilation provisions given in ADF 2010 can be used where security is not an issue In this case minimum high ext...

Page 4: ...in ceilings Exhaust air from kitchen bathroom to outside via air brick Part no PVC505NS Supply and extract ducts from external air bricks to the unit needs to be insulated Minimum 300mm Top of ceilin...

Page 5: ...erving kitchen and bathroom Unit serving kitchen and two bathrooms Figure 8 Figure 9 For good EMC engineering practice any sensor cables or switched live cables should not be placed within 50mm of oth...

Page 6: ...eds to operate the fan to maximum airflow See wiring diagram for details of operating this facility 7 2 Humidity adjustment This product contains an internal humidity sensor fitted into the airflow ex...

Page 7: ...ffected 3 2 When handling the equipment care should be taken with corners and edges and that the weight distribution within the unit is considered Lifting gear such as slings or ropes must be arranged...

Page 8: ...8 05 09 13 Leaflet Number 671632 Western Industrial Estate Caerphilly United Kingdom CF83 1NA T 029 2085 8400 F 029 2085 8444 E info nuaire co uk W www nuaire co uk...

Reviews: