SECTION 4: INSTALLATION 

 
4.1   Operational Components 
 

1.  Power Switch  
2.  Oxygen Outlet  
3.  Flow Meter with Control Knob 
4.  Air Filters  
5.  Place for Humidifier bottle 

(not to use 

with the air spray brush) 

6.  LED Display 

6.a Time Counting System 

   (CU= current use session time/total use) 
 

6.b Power Disconnection 

  6.c Abnormal Voltage 
 

6.d Power “ON” Indicator Light 

7.  Circuit Breaker Reset Button 
8.  Handle 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

6a 

6b 

6c 

6d 

Summary of Contents for OxyOasis

Page 1: ...Page 1 2014 NuAge Beauty Inc All Rights Reserved 206485 NA OO 10 1 0814 7 U ...

Page 2: ...ntative or our Customer Service Department We look forward to the opportunity of offering additional products and services to you Please contact us at 1 877 818 9988 or visit us at www nuagebeauty com In order to offer the highest quality products and services to our customers we welcome your feedback regarding your new OxyOasis System Thank you for your business __________________________________...

Page 3: ...___ 10 4 3 Connecting Tubing ______________________________________ 10 4 4 Assembling and Connecting the Micro Mist Air Spray Brush _______ 11 Section 5 Operation 5 1 Operating Your OxyOasis 12 5 2 Operating your Micro Mist Air Spray Brush _____________________ 12 5 3 Right Wrong Ways to Use your OxyOasis System ________________ 14 Section 6 OxyOasis Protocols featuring Oxygen Botanicals 6 1 Mini ...

Page 4: ...exist The distributor and manufacturer do not accept responsibility of any kind for customer loss due to use of or reliance upon this document The distributor and manufacturer reserve the right to make changes without notice in the product described or contained herein in order to improve design and or performance The distributor and manufacturer assume no responsibility or liability for the use o...

Page 5: ...xyOasis System No attempt has been made to designate as trademarks or service marks all words or terms in which proprietary rights might exist The inclusion exclusion or definition of a word or term is not intended to affect or to express a judgment on the validity or legal status of the word or term as a trademark service mark or other proprietary term ...

Page 6: ...ain socket used match those indicated on the manufacturer s plate on the rear panel of the machine We recommend avoiding the use of extension cables or even adapters as they are sources of sparks and therefore of fire The OxyOasis must only be used for oxygen air spray facial sessions Do not use in a specifically magnetic environment MRI etc Do not carry out any facial session in areas exhibiting ...

Page 7: ...concentrator DANGER FIRE HAZARD NO SMOKING This device supplies high concentrations of oxygen which promotes rapid burning Do not allow smoking open flames or other ignition sources within 5 feet of this device or its accessories Oil grease or other petroleum products should NEVER be used on or around the unit Do not use extension cords with this unit WARNING Risk of Electric Shock Do not remove t...

Page 8: ...cules chemically bond to the zeolite while the oxygen flows through unimpeded to the user The machine enables a continuous flow of oxygen to the user by alternating the use of each cylinder When compressed air is directed to one cylinder the air pressure in the other cylinder is reduced to 0 PSI The reduction in air pressure purges the nitrogen from the zeolite and prepares the cylinder for the ne...

Page 9: ...trol Knob 4 Air Filters 5 Place for Humidifier bottle not to use with the air spray brush 6 LED Display 6 a Time Counting System CU current use session time total use 6 b Power Disconnection 6 c Abnormal Voltage 6 d Power ON Indicator Light 7 Circuit Breaker Reset Button 8 Handle 1 7 6 3 6 5 2 4 8 6a 6b 6c 6d ...

Page 10: ...ir Before you operate the unit make sure these filters are clean and positioned correctly see Section 8 Maintenance for cleaning instructions 8 Test the concentrator by pressing the power switch ON 9 Next turn the knob of the flow valve counter clockwise allowing oxygen to flow This should cause the steel ball inside the flow meter to float on the flow of oxygen in accordance with the flow rate se...

Page 11: ...ush 1 Attach tail piece to the base on the bottom of the spray brush 2 Follow all steps from section 4 3 to connect oxygen administration tubing 3 Connect the open tube end to the tail piece input fitting on the air spray brush Serum fluid cup Tail piece Spray brush base Dropper Oxygen serum trigger Trigger adjustment knob Screw tail piece here ...

Page 12: ...nob counter clockwise Adjust to 3 5 LPM for best results 5 2 Operating your Micro Mist Air Spray Brush Follow the steps outlined in section 4 4 to assemble the spray brush and connect the oxygen administration tubing 1 Fill the serum fluid cup reservoir with liquid activators and desired serums see protocols for product suggestions NEVER use essential oils for oxygen spray 2 Pull the trigger halfw...

Page 13: ... nozzle sitting on your middle finger and the end of the spray brush cradled in the groove of your thumb Keeping your hand relaxed Fold your little ring and middle finger around the base of the spray brush Rest your index finger on the side or base of the fluid cup Leaving your thumb to rest on the trigger enabling you to control oxygen serum flow Keeping your hand relaxed during session reduces s...

Page 14: ... regulate the amount of serum being sprayed by how far you pull the trigger back adjust from the back trigger adjustment knob Distance when spraying 1 When spraying large areas such as cheek or the forehead you must be 5 6 cm about 2 inches away from the surface of the skin 2 When spraying smaller areas such as the eye nose or upper lip you must be 1 cm about inch away from the surface of the skin...

Page 15: ...M 4 Start by pulling the trigger halfway to release the gentle adjustable flow of oxygen enriched air over the facial area with quick back and forth motions stay close to the skin at all times for best results work in small areas and spend more time on areas of concern 5 Pull trigger all the way back now to spray the solution over the area to soothe and refresh pull further away from skin and alte...

Page 16: ...st air spray brush fill the fluid cup halfway with water based activators or serums 8 Start by pulling the trigger half way to release the gentle adjustable flow of oxygen enriched air over the facial area with quick back and forth motions stay close to the skin at all time for best results work in small areas and spend more time on areas of concern 9 Pull trigger all the way back to spray the sol...

Page 17: ...sque 8 Prepare the micro mist air spray brush fill up the fluid cup halfway with water based activator and serums 9 Start by pulling the trigger half way to release the gentle adjustable flow of oxygen enriched air over the facial area with quick back and forth motions stay close to the skin at all time for best results work in small areas and spend more time on areas of concern 10 Pull trigger al...

Page 18: ...Start up again If the device does not start contact your provider Air brush doesn t operate correctly or the machine makes a weird beeping noise The air brush is not properly connected Make sure the hose is strongly connected on both ends DO NOT USE THE HUMIDIFIER BOTTLE WITH THE AIR BRUSH Air brush doesn t release serum when trigger pulled all the way back Product used is not liquid enough Air br...

Page 19: ...completely dry before reinstalling CAUTION Do not operate the concentrator without the filters installed or while either filter is damp Oxygen Tubing Accessories 1 Clean and or replace your oxygen tubing and accessories as needed 2 The micro mist air spray brush must be cleaned for each new customer Exterior Cabinet You may clean the exterior of the concentrator cabinet as needed using a damp clot...

Page 20: ...ress down and pull back on the trigger This will create back flow causing the water in the cup to bubble Let the liquid bubble for a few seconds then release your finger from the tip of the serum cup Keeping the trigger pressed down and pulled back spray water through Repeat this process 3 4 times Dry the cup and lid and make sure you have sprayed all water out On the final rinse use a sterilizing...

Page 21: ...z Power Consumption 300 Watts Operating Environment 5 ºC 40 ºC 80 Relative Humidity non condensing Dimensions Length 15 4 39 cm Width 12 2 31 cm Height 25 2 64 cm Weight Product 52 lbs 23 7 Kg Shipped 57 lbs 26 Kg Sound Level 52 dbA Storage Conditions 40 ºC to 50 ºC 93 R H Alarms Power failure buzzing sound red light on abnormal voltage yellow light on if too low or too high ...

Page 22: ...m and has a separate limit 3 month warranty g If a product is not covered by warranty customer will sign an Authorization Repair Work Order of the evaluated findings and estimation of required work to bring the equipment up to manufacturer specifications 4 COVERAGE HOURS The service hours covered under this agreement are 7 30 A M to 5 30 P M Monday through Friday local time excluding holidays and ...

Page 23: ...loyees and its successors and assigns 12 FORCE MAJEURE Neither party shall be liable for any failure or delay in performance under this Agreement other than for delay in the payment of money due and payable hereunder to the extent said failures or delays are proximately caused by causes beyond that party s reasonable control and occurring without its fault or negligence or party to substantially m...