![Nu-Vu QB-3/9 Manual Download Page 25](http://html1.mh-extra.com/html/nu-vu/qb-3-9/qb-3-9_manual_1715571025.webp)
SUB–123 OWNER'S MANUAL
ELECTRICAL SCHEMATICS
NU-VU
®
FOOD SERVICE SYSTEMS
MENOMINEE MICHIGAN 49858-0035
(800) 338-9886
Sales Fax (906) 863-5889
♦ Service Fax (906) 863
-6322
page
17
C. If the difference is less than 25
in the Oven or 15
in the Proofer, a simple adjustment of the dial may
solve the problem:
1.
Remove the Knob of the Temperature Control by pulling it straight out from the face of the
Control Panel.
2.
Hold the black plastic Knob securely with the back of the clear plastic dial toward you. Use
a #1 Phillips screwdriver to loosen these screws from 3/4 to 1 full turn, but
do not remove
them!
3.
To increase the temperature inside the Oven or Proofer, carefully rotate the index line on the
clear dial clockwise. Each "click" of adjustment is equal to approximately 5
of temperature
change in the Oven and 2
of temperature change in the Proofer. To decrease the inside
temperature rotate the clear dial counter-clockwise.
4.
Gently tighten the dial screws and install the Control Knob. Check the Control setting
against the test instrument and repeat this procedure if necessary.
D. If this procedure fails to bring the temperature reading within the desired specs call NU-VU
®
service
department at 800-338-9886.
DOOR LATCH, How To Adjust:
Determine if the Oven Door [41] or Proofer Door [42]
is fitting too loose (it will leak moisture and heated air
past the Gasket) or too tight (it will not close properly,
or will "pop" open unexpectedly). If it is too loose the
Door Latch [44] must be adjusted OUT (away from the
unit); if it is too tight the Door Latch must be adjusted
IN (towards the unit). Please proceed as follows:
A. Loosen the two acorn nuts inside the Latch Cover
[45] with a 3/8" box wrench. Pull the Latch Cover
straight out from the Door to remove it, and then
remove the acorn nuts.
B. Open the Door and take careful notice of the
adjustment plate position against the body of the
Door Latch.
C. Hold the adjustment plate against the body of the
Door Latch with one hand while you loosen the
three mounting screws with the other hand. Back
the screws out approximately three full turns.
D. CAREFULLY move the Door Latch body IN or
OUT under the adjustment plate
one notch at a
time
. Make sure the Door Latch stays straight up and down, and tighten the mounting screws.
Test the Door for proper closing and sealing (refer to the
DOOR TEST PROCEDURE
).
E. Repeat steps "C" and "D" if you are not satisfied with the Door adjustment. If the Door tests as
satisfactory make sure the three mounting screws are tightened securely.
F. Install the acorn nuts on the ends of the top and bottom Door Latch screws. Turn the nuts on all
the way until they just contact the back side of the latch bracket, then loosen them by 1½ to 2 full
turns. Install the Latch Cover and tighten the acorn nuts lightly to hold the Latch Cover in place.
DOOR TEST PROCEDURE:
A. Cut one or two strips of paper approximately 1" wide and 8" to 10" long.
B. Open the Door slightly, insert a strip of paper between the Gasket [46] and Door Jamb and close
the Door.
C. Slowly pull the paper strip out. You should feel some resistance as you pull the strip from
Fig. #7 – Door Latch Assembly