NTI XTENDEX Series ST-C5RS-LCRS232 Installation And Operation Manual Download Page 8

NTI XTENDEX RS232 Extender 

 

5

 
 
 
 
 
 

3. Connect a CAT5e/6/7 cable between the Master and Slave units.    For devices controlled by up to 115,200 baud rate, this 
cable can be up to 3935 feet in length (1200 meters).    For devices controlled by higher baud rates (up to 921,600), this cable can 
be up to 328 feet in length (100 meters).  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                                                                Figure 3- Connect CATx cable 

Plug-in and Boot Up 

 

1.

 

Power up the CPU and extended device.     The red power LED on each extender should illuminate.    Try sending 
communication between the CPU and the serially-controlled device.   The CPU and device should each react as if they were 
directly connected to each other. 

 

Note: The yellow (“Tx”) and green (“Rx”) LEDs on each RJ45 connector will flash anytime data traffic is passing between 
the Master and Slave, indicating proper CATx cable connection and communication.  
 

If insufficient power is provided by the connection to the CPU or the serial device, the red power LED will not illuminate.  In this 
case, an external power supply (9-30VDC) will need to be connected (sold separately- contact NTI).  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                                                 Figure 4- Connect optional power supply 

 
 
 

Summary of Contents for XTENDEX Series ST-C5RS-LCRS232

Page 1: ...Man249 Rev 9 25 15 ST C5RS LC RS232 EXTENDER Installation and Operation Manual XTENDEX Series ST C5RS LC RS232 Extender...

Page 2: ...o 44202 CHANGES The material in this guide is for information only and is subject to change without notice Network Technologies Inc reserves the right to make changes in the product design without res...

Page 3: ...Plug in and Boot Up 5 DIN Rail Mounting 6 Technical Specifications 7 Interconnection Cable Wiring Method 7 Warranty Information 8 TABLE OF FIGURES Figure 1 Connect Local extender to CPU 4 Figure 2 Con...

Page 4: ...ered devices Powered by attached devices though DB9 serial cable If additional power is required a 9 30VDC power supply can be wired to the screw terminal pair sold separately Regulatory Approvals CE...

Page 5: ...6 7 cable 4 Terminal Block for connecting 9 30VDC power supply if required optional sold separately 5 RS232 Connector 9D female for connecting to the RS232 port on the CPU Master Unit or serial devic...

Page 6: ...c All cables should be installed in such a way that they do not cause stress on their connections to the equipment Extended lengths of cable hanging from a connection may interfere with the quality of...

Page 7: ...n the Master see label on back of extender and the serial port on the back of the CPU or other serial controlling device Figure 1 Connect Local extender to CPU 2 Connect the supplied 6 inch 9DB male t...

Page 8: ...should illuminate Try sending communication between the CPU and the serially controlled device The CPU and device should each react as if they were directly connected to each other Note The yellow Tx...

Page 9: ...o holes on the back of the extender screws are provided Then set the extender on the rail against the spring clips side first apply a small amount of pressure and rotate the extender up to lock the ra...

Page 10: ...C Operating humidity 5 95 Non Condensing Dimensions WxDxH In Local or Remote 1 63x3 13x0 88 Drivers required none Regulatory Approvals CE FCC RoHS INTERCONNECTION CABLE WIRING METHOD The connection c...

Page 11: ...ate of purchase Please contact Network Technologies Inc at 800 742 8324 800 RGB TECH or 330 562 7070 or visit our website at http www networktechinc com for information regarding repairs and or return...

Reviews: