NTI XTENDEX Series ST-C5RS-LCRS232 Installation And Operation Manual Download Page 10

NTI XTENDEX RS232 Extender 

 

7

 

TECHNICAL SPECIFICATIONS 

 

 

 

RS232 Connectors 

9DB female 

RS232 Baud Rate 

115,200  to 3935 feet (1200 meters) 
921,600  to 328 feet (100 meters) 

RS232 Compatibility 

RXD,TXD,RTS,CTS 

Communication Mode 

Full Duplex Data 

RS232 protocols supported 

All 

 

 

Interconnect Cable 

CAT5e/6/7 straight through cable for EIA/TIA 568 B wiring terminated w/ male 
RJ45 connectors 

Remote and Local Unit Power 

device powered through 9DB cable 
Optional:  9-30VDC adapter (if needed) 

Power Consumption 

40mA   /   360mW 

Operating Temperature 

-30°C to  75°C 

Operating humidity 

 5 - 95% Non-Condensing 

Dimensions  WxDxH (In.)  (Local or Remote) 

1.63x3.13x0.88 

Drivers required 

none 

Regulatory Approvals 

CE,FCC,RoHS 

 

INTERCONNECTION CABLE WIRING METHOD 

 

The connection cable between the Remote and Local is terminated with RJ45 connectors and must be wired according to the 
EIA/TIA 568 B industry standard.   Wiring is as per the table and drawing below.    
 
 
 

Pin 

Wire Color 

Pair 

Function 

 1 

White/Orange 

 2 

Orange 

 3 

White/Green 

 4 

Blue  1 

 5 

White/Blue 

 6 

Green 3 

 7 

White/Brown 

 8 

Brown 4 

 
 

                                                                                              Figure 5- View looking into RJ45 female 

9DB Female on Extender 

 

Pin 

Function 

1 N/U 
2 TXD 
3 RXD 
4 N/U 
5 GND 
6 N/U 
7 CTS 
8 RTS 
9 N/U 

 
N/U = Not Used 
 
 
 
 
 
 
 
 

T

1
+

R

2
-

T

3
+

R

4
-

T

5
+

R

6
-

T

7
+

R

8
-

Pair 2

Pair 1

Pair 4

Pair 3

Summary of Contents for XTENDEX Series ST-C5RS-LCRS232

Page 1: ...Man249 Rev 9 25 15 ST C5RS LC RS232 EXTENDER Installation and Operation Manual XTENDEX Series ST C5RS LC RS232 Extender...

Page 2: ...o 44202 CHANGES The material in this guide is for information only and is subject to change without notice Network Technologies Inc reserves the right to make changes in the product design without res...

Page 3: ...Plug in and Boot Up 5 DIN Rail Mounting 6 Technical Specifications 7 Interconnection Cable Wiring Method 7 Warranty Information 8 TABLE OF FIGURES Figure 1 Connect Local extender to CPU 4 Figure 2 Con...

Page 4: ...ered devices Powered by attached devices though DB9 serial cable If additional power is required a 9 30VDC power supply can be wired to the screw terminal pair sold separately Regulatory Approvals CE...

Page 5: ...6 7 cable 4 Terminal Block for connecting 9 30VDC power supply if required optional sold separately 5 RS232 Connector 9D female for connecting to the RS232 port on the CPU Master Unit or serial devic...

Page 6: ...c All cables should be installed in such a way that they do not cause stress on their connections to the equipment Extended lengths of cable hanging from a connection may interfere with the quality of...

Page 7: ...n the Master see label on back of extender and the serial port on the back of the CPU or other serial controlling device Figure 1 Connect Local extender to CPU 2 Connect the supplied 6 inch 9DB male t...

Page 8: ...should illuminate Try sending communication between the CPU and the serially controlled device The CPU and device should each react as if they were directly connected to each other Note The yellow Tx...

Page 9: ...o holes on the back of the extender screws are provided Then set the extender on the rail against the spring clips side first apply a small amount of pressure and rotate the extender up to lock the ra...

Page 10: ...C Operating humidity 5 95 Non Condensing Dimensions WxDxH In Local or Remote 1 63x3 13x0 88 Drivers required none Regulatory Approvals CE FCC RoHS INTERCONNECTION CABLE WIRING METHOD The connection c...

Page 11: ...ate of purchase Please contact Network Technologies Inc at 800 742 8324 800 RGB TECH or 330 562 7070 or visit our website at http www networktechinc com for information regarding repairs and or return...

Reviews: