Lx Series Installation and Operation Instructions
│
Trinity Lx
11
Figure 3-2(a) Wall Mounting Installations (Lx150-200)
Remove the upper wall mount bracket from the
back of the boiler.
Failure to follow instructions may
result in fire, serious injury, or death.
Secure the upper wall mount bracket to a solid
wall using field supplied lag screws (anchors
when mounting on a concrete wall) that are
adequate to support the weight of the boiler.
Ensure the bracket is mounted in the level
position. Refer to Table 2-1 Specifications for
boiler weight.
This unit requires two people to lift it
or damage and injury may result.
Mount the boiler to the bracket by aligning the
slots in the back of the boiler with the hooks
protruding from the wall bracket. The top of
the slots must rest at the bottom of the groove
in the hooks of the wall mount bracket.
Pull the bottom of the unit away from the wall
to allow the installation of the lower wall
mount bracket (included with boiler). The
bracket will snap into place using the slots
provided in the bottom of the unit (ensure the
snaps lock into place, once installed the bracket
should not be easily removed).
1” Clearance for Vent and
Hot Water Piping.
Ensure that the top of each
slot rests on the bottom of the
grooves in the wall bracket.
Bottom Bracket is in
Lx Installation Kit Box