NTI RACKMUX-V17-N-8USBHD-IP RACKMOUNT DRAWER WITH USB KVM SWITCH AND KVM ON IP
36
If Security is disabled and the user attempts to login to Command Mode
with the command key, the login screen will include the instruction
“Press F1 to Autologin”.
With security disabled, Autologin provides full access to all connected
CPUs and all users except the administrator must use it to login.
When security is enabled, Autologin is not available and the user must
login using the administrator assigned user name and password. The
user will have access to only those CPU ports as configured by the
administrator.
Figure 47- Login screen with security disabled
Serial Baud Rate
The serial baud rate for the UNIMUX can be changed by pressing <
B
>
from the System Configuration menu. In order to control
the UNIMUX via RS232 (page 40), the baud rate must be set the same as the communication port on the control terminal
attached to the UNIMUX (page
Error! Bookmark not defined.
)
The baud rate value can be set to 115000, 57600, 38400, 19200, 9600, 4800, 2400, or 1200. A data protocol of 8 data bits, no
parity, and 1 stop bit is used for communications. With the edit field highlighted, press the <
Left arrow
> or <
Right arrow
>
to change the value of the baud rate.
Note: The baud rate can also be changed from the RS232 Command Protocol (see page 40).
For more on RS232 Control, see page 40.
Figure 48- Adjust Baud Rate