NTI Manual Ethernet Switch
6
Plug-in and Boot Up
1. Connect the AC adapter power connector to the 12VDC port on the ETH-4X1 Manual Ethernet Switch.
Make sure the power connector is properly inserted. (See Fig. 3.)
2. Plug the AC adapter into a power outlet. The “Power” LED on the ETH-4X1 Manual Ethernet Switch should
illuminate indicating that a proper power connection has been made. Status LED "1" should also illuminate
indicating a connection between the "COMMON" port and user selectable port 1.
Figure 3- Connect the AC adapter
3. Power up the COMMON and SELECTABLE device(s). The COMMON device should react as if it were directly
connected to the SELECTABLE device plugged into user selectable port 1.
RS232
To use the RS232 port (optional) , connect a crossed female serial cable from a CPU serial port to the DB9 pin male RS232
port on the ETH-4X1-RS Manual Ethernet Switch. Connections are as follows:
RS232 Connector (DB9 Male)
Pin
Signal
Pins at CPU
2
RxD
3
3
TxD
2
5
GND
5
RS-232 program setup parameters:
•
9600
baud
•
8 bit data
•
1 stop bit
•
no
parity
•
no flow control
1
Mating Face of Male DB9
2
3
4
5
6
7
8
9
12 VDC
Adapter
ADAPTER
Barrel
(Tip of
barrel)
(Rear of
barrel)
Power Connector
2.1 mm x 5.5 mm Male
12VDC @ .5A OUTPUT
Power LED
Status LEDs
Front View of ETH-4X1-RS
NETWORK
Tel: 330-562-7070
www.nti1.com
1275 Danner Drive
Fax: 330-562-1999
12VDC
.5A
-
+
RS232
R
MANUAL ETHERNET SWITCH
ETH-4X1-RS
Power
NTI
NETWORK
TECHNOLOGIES
INCORPORATED
R
COM
MO
N
4
3
2
1
1
2
3
4
DB9 Male Connector